# Attic Baffle Vent Calculator

> Estimate how many rafter baffle vents you need to keep soffit airflow clear above insulation.

Page: https://craftquantities.com/calculators/insulation-efficiency/attic-baffle-vent-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Baffle vents needed: 30 baffles (one per rafter bay) for Attic Width Along Eave 39 ft, the page's opening figures; on the metric page, 12 m gives 30 baffles (one per rafter bay). Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Attic Width Along Eave | `atticWidth` | 12 m | 39 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Rafter Spacing | `rafterSpacingIn` | 40 cm (~16 in) | 16 in | `16`, `24` |

- **Attic Width Along Eave**: The length of the eave line where rafter bays need baffles.
- **Rafter Spacing**: The on-center spacing between rafters.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Baffle vents needed** | 30 baffles (one per rafter bay) |
| Attic width | 12 m |

### US customary

| Result | Value |
|---|---|
| **Baffle vents needed** | 30 baffles (one per rafter bay) |
| Attic width | 39 linear ft |

## How it is worked out

The working the page shows, in order: Attic width; then baffle vents needed.

The method, derived in full:

- [Ventilation: Net Free Area, Air Change and the Openings That Deliver Them](https://craftquantities.com/methodology/ventilation-openings-and-air-change/): Why a wooden louvre delivers a quarter of the hole you cut and a metal one three-quarters, why intake and exhaust have to be balanced or the roof ventilates the house, and why doubling the pressure does not double the flow.

What this calculation does not cover:

- The figure covers one eave line, because that is the only length asked for. A gable roof carries a soffit down each long side and needs the calculation run for each, so the 30 baffles returned for a 12 m eave at 16 in centres is 60 for the pair, and a hipped roof has eave on all four sides.
- The result counts bays, not the number of baffle sections a bay swallows. Rafter baffles are commonly sold in sections of about 1.2 m (4 ft), enough to carry the channel over the top plate and the first stretch of loft insulation, so where the vented channel must continue up the rafter — the vaulted assembly described in the FAQ, running soffit to ridge — a 4 m rafter run takes three or four sections in every bay and the quantity to order is that multiple of the number shown.
- Baffles protect an airflow path; they do not create one. Nothing here tests whether the soffit actually has vents in it, or whether their net free area meets the 1:150 or 1:300 attic rule, and a baffle fitted above a solid soffit or an uncut sheathing panel achieves nothing. Intake area also has to be balanced against ridge or gable exhaust before the channel will draw.
- The count says nothing about the depth of the channel a baffle holds open or its height above the finished insulation. A minimum clear air gap between the baffle and the underside of the sheathing is normally required — one inch is the figure most often quoted, but the clearance that applies is set by the code in force — and at a shallow eave that gap plus full insulation depth may not fit beneath the rafter at all, which is a raised-heel truss or insulation-depth question rather than a baffle-count one.
- Dividing the eave length by the rafter spacing assumes parallel, uninterrupted bays for the whole run. Hip corners with jack rafters, dormers, valleys, chimneys and the bay that dies against a gable wall all break that pattern, and the number neither removes bays with no soffit vent below them nor adds the short jack-rafter bays a hip creates.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- One baffle vent is installed per rafter bay; bay count = attic width along the eave / rafter spacing, rounded up

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do baffles matter if I already have soffit vents?**

Without a baffle, blown-in or batt insulation can slump or get pushed into the soffit opening, blocking the airflow path from the soffit vent into the attic — baffles hold a clear channel open above the insulation.

**Do I need one baffle per rafter or per bay?**

One per bay (the space between two rafters) — the baffle spans the gap between adjacent rafters, so bay count (not rafter count) determines how many you need.

**Does this apply to cathedral/vaulted ceilings too?**

Yes — vaulted ceiling assemblies with venting behind the insulation use the same baffle-per-bay approach, running the full length of each rafter bay from soffit to ridge vent.

## Related calculators

- [Attic and Loft Ventilation Calculator (Intake, Exhaust and Vent Count)](https://craftquantities.com/calculators/insulation-efficiency/attic-ventilation-calculator/)
- [Attic Fan CFM Calculator](https://craftquantities.com/calculators/plumbing-hvac/attic-fan-cfm-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/attic-baffle-vent-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/attic-baffle-vent-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `attic-baffle-vent-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/attic-baffle-vent-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/attic-baffle-vent-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.