# Air Changes Per Hour (ACH50) Calculator

> Calculate a building's ACH50 airtightness metric from a blower door test's CFM50 reading.

Page: https://craftquantities.com/calculators/insulation-efficiency/air-changes-per-hour-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

ACH50 (air changes per hour at 50 Pa): 10.4 ACH50 for Conditioned Floor Area 1080 sq ft and Average Ceiling Height 8 ft, the page's opening figures; on the metric page, 100 m² and 2.4 m give 10.6 ACH50. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Conditioned Floor Area | `floorArea` | 100 m² | 1080 sq ft | m2, ft2, mm2, in2; range 0.01–1000 m² |
| Average Ceiling Height | `ceilingHeight` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd; range 0.01–6 m |
| Blower Door CFM50 Reading | `cfm50` | 1500 | 1500 | range 100–10000 |

- **Conditioned Floor Area**: The total conditioned (heated/cooled) floor area of the building.
- **Average Ceiling Height**: The average ceiling height across the conditioned space.
- **Blower Door CFM50 Reading**: The airflow reading from a blower door test at 50 Pascals of pressure difference.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **ACH50 (air changes per hour at 50 Pa)** | 10.6 ACH50 |
| Building volume | 240 m³ |

### US customary

| Result | Value |
|---|---|
| **ACH50 (air changes per hour at 50 Pa)** | 10.4 ACH50 |
| Building volume | 8,640 ft³ |

## How it is worked out

Fairly leaky — typical of an older, un-air-sealed home; many energy codes target under 3-5 ACH50 for new construction.

The working the page shows, in order: Building volume; then aCH50 (air changes per hour at 50 Pa).

The method, derived in full:

- [Airtightness, Infiltration and Moisture](https://craftquantities.com/methodology/airtightness-and-infiltration/): Why a blower-door result is not an air change rate, why a leak at the top of a house matters far more than the same leak halfway up, and why sealing without ventilating moves the problem rather than solving it.

What this calculation does not cover:

- ACH50 is leakage measured while a fan holds the building at 50 Pa, not the rate at which air actually changes in service. Real infiltration is a fraction of this figure and varies with wind, stack effect, exposure, shielding and building height, so this result is not a ventilation rate and not a number to feed straight into a heat-loss or plant-sizing calculation.
- The test behind the reading is run with trickle vents, extract terminals and other intentional openings closed or sealed, so a low result is not evidence the building is ventilated. A dwelling driven down towards the tight end without mechanical ventilation added at the same time has been sealed, not improved.
- The calculation divides whatever CFM50 you type; it does not check the reading. Temperature and wind correction on the day, a single-point reading versus a multi-point fit, pressurisation versus depressurisation, and how thoroughly the crew sealed intentional openings all move the flow figure, and none of them are visible here.
- Volume is taken as floor area times average ceiling height, and the fields only reach dwelling scale — a floor area above 1,000 m² (about 10,760 sq ft) or a ceiling above 6 m (about 20 ft) is replaced with the limit. Whether a conditioned basement, a room in the roof or the space between storeys belongs inside the tested volume is settled by the test protocol and by the two numbers you enter, so the ACH50 on a certificate for the same house can differ from this one.
- This is not a compliance check. It applies no code target, no climate zone and no certification scheme's pass mark, and it does not produce air permeability in m3/(h.m2) of envelope area, which is the figure a UK or European air-leakage test is judged against. The flow field is CFM only, so a certificate quoting m3/h at 50 Pa has to be converted before it goes in the box.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Standard blower door test formula: ACH50 = (CFM50 x 60) / building volume in cubic feet

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What's a 'good' ACH50 number?**

Lower is tighter/better: many modern energy codes target 3-5 ACH50 or lower for new construction, while older, un-air-sealed homes can measure well above 10-15 ACH50.

**Can a house be too airtight?**

Yes — very tight homes need mechanical ventilation (like an ERV or HRV) to bring in fresh air on purpose, since they no longer get enough incidental fresh air through leaks the way a drafty older home does.

**Do I need a professional to get CFM50?**

Yes — CFM50 comes from a blower door test performed with calibrated equipment, typically by an energy auditor or HERS rater. This calculator turns that professional reading into the normalized ACH50 metric.

## Related calculators

- [R-Value Calculator](https://craftquantities.com/calculators/insulation-efficiency/r-value-calculator/)
- [Attic Fan CFM Calculator](https://craftquantities.com/calculators/plumbing-hvac/attic-fan-cfm-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/air-changes-per-hour-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/air-changes-per-hour-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `air-changes-per-hour-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/air-changes-per-hour-calculator.json

---
Source: https://craftquantities.com/calculators/insulation-efficiency/air-changes-per-hour-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.