# Excavation Shoring Lateral Active Soil Pressure Calculator (Rankine)

> Estimate the lateral active earth pressure a shoring wall or trench box must resist, using the classical Rankine theory for cohesionless soil.

Page: https://craftquantities.com/calculators/heavy-civil/shoring-active-pressure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Total active lateral force per unit length of wall: 1,900 lbf/ft for Soil Unit Weight γ 114.59 pcf, the page's opening figures; on the metric page, 18 kN/m³ gives 27 kN/m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Soil Unit Weight γ | `soilUnitWeight` | 18 kN/m³ | 114.586 pcf | knm3, pcf_weight; range 12–24 kN/m³ |
| Soil Internal Friction Angle φ (°, Typical Range 28-40° for Sand — Requires a Geotechnical Report) | `frictionAngle` | 30 | 30 | range 20–45 |
| Excavation/Retained Height | `excavationHeight` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.01–10 m |

- **Soil Unit Weight γ**: The total (moist) unit weight of the retained soil — γ, not its dry density.
- **Soil Internal Friction Angle φ (°, Typical Range 28-40° for Sand — Requires a Geotechnical Report)**: The soil's internal friction angle, in degrees, used in the Rankine active pressure coefficient.
- **Excavation/Retained Height**: The vertical height of the excavation face or shoring wall being checked.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Total active lateral force per unit length of wall** | 27 kN/m |
| Peak lateral pressure at base of cut | 18 kN/m² |
| Active pressure coefficient Ka | 0.33 (dimensionless) |

### US customary

| Result | Value |
|---|---|
| **Total active lateral force per unit length of wall** | 1,900 lbf/ft |
| Peak lateral pressure at base of cut | 381.95 psf |
| Active pressure coefficient Ka | 0.33 (dimensionless) |

- Confidence: low.

## How it is worked out

This is a preliminary Rankine active-pressure estimate for COHESIONLESS soil under simplified conditions (no water table, no surcharge, vertical smooth wall) — a screening/educational estimate, NOT a stamped design. Cohesive soils, groundwater, surcharge loads (equipment, spoil piles, adjacent structures), sloped ground, braced/strutted multi-level systems (which use Peck's empirical apparent-pressure diagrams instead), and seismic loading all require different methods not captured here. Per OSHA 29 CFR 1926 Subpart P, the actual excavation protective system must be selected by a competent person using the Subpart P tables or designed by a registered professional engineer using site-specific geotechnical data — this calculator is not a substitute for that process.

The working the page shows, in order: Peak lateral pressure at base of cut; Active pressure coefficient Ka; then total active lateral force per unit length of wall.

The method, derived in full:

- [Lateral Earth Pressure and the Wall That Resists It](https://craftquantities.com/methodology/lateral-earth-pressure/): Why one soil has three pressures that differ ninefold, why the resultant acts a third of the way up rather than halfway, and why water is what actually fails retaining walls.

What this calculation does not cover:

- There is no water in this model. Below a water table the soil pushes with its buoyant weight, but the water adds its own full hydrostatic pressure on top, and Ka does not reduce that part — the load on a saturated face is much higher than the figure here. Perched water, seepage through a granular lens, and a table that rises after rain are not checked at all.
- No surcharge is included. Spoil heaped along the crest, an excavator or crane tracking beside the cut, stacked pipe, site traffic, and the footings of any adjacent structure all add lateral load this ignores. On a tight site the surcharge can be the larger part of the total.
- Active pressure only develops if the wall moves enough to let the soil behind it relax. A stiff or tightly propped wall that cannot yield attracts at-rest pressure, which is substantially higher, and a multi-level braced excavation is designed to an apparent-pressure envelope of a different shape entirely. Size a strut off this triangular distribution and it comes out light.
- The formula is for cohesionless granular soil against a vertical smooth wall with level ground. It carries no cohesion term, no wall friction, no allowance for sloped or benched ground above the cut, and no layering — clay, silt and mixed fill do not behave this way, and a cohesive face standing unsupported for a shift is not evidence the pressure is low.
- This is a pressure figure, not a shoring design. It does not size sheets, soldier piles, wales, struts or anchors, does not set embedment depth below formation, applies no factor of safety, and checks nothing for toe stability, base heave or overall slope failure. Under OSHA 29 CFR 1926 Subpart P the protective system must come from the Subpart P tables, a trench shield manufacturer's tabulated data, or a registered professional engineer's design.

A professional must decide:

- This is a pressure figure, not a shoring design. It does not size sheets, soldier piles, wales, struts or anchors, does not set embedment depth below formation, applies no factor of safety, and checks nothing for toe stability, base heave or overall slope failure.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Rankine active earth pressure theory for a cohesionless soil, vertical smooth wall, horizontal ground surface, no surcharge, no water table: Ka = tan²(45° − φ/2); peak pressure at base p_max = γ×H×Ka; total active force per unit length of wall Pa = 0.5×γ×H²×Ka. This is the standard textbook formula (used in the Caltrans Trenching and Shoring Manual and standard geotechnical references). OSHA 29 CFR 1926 Subpart P classifies soil by Type A/B/C using field tests (unconfined compressive strength), NOT by friction angle or Ka — the actual protective system must be selected per Subpart P's prescriptive tables or designed by a registered professional engineer (1926.652(b)/(c)); this formula is not itself an OSHA-published method.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Does this account for OSHA's soil classification (Type A/B/C)?**

No. OSHA 29 CFR 1926 Subpart P classifies soil by Type A/B/C using field tests such as unconfined compressive strength — not by friction angle or the Rankine active pressure coefficient (Ka). The actual protective system for an excavation must be selected using Subpart P's prescriptive tables or designed by a registered professional engineer per 1926.652(b)/(c); this formula is not itself an OSHA-published method.

**What conditions does this Rankine formula assume, and when does it not apply?**

It assumes cohesionless soil, a vertical smooth wall, a horizontal ground surface, no surcharge, and no water table. Cohesive soils, groundwater, surcharge loads (equipment, spoil piles, adjacent structures), sloped ground, braced/strutted multi-level systems (which instead use Peck's empirical apparent-pressure diagrams), and seismic loading all require different methods this calculator does not capture.

**Is this enough to design a shoring system?**

No — this is a preliminary screening/educational estimate only, not a stamped design. Per OSHA 29 CFR 1926 Subpart P, the excavation protective system must be selected by a competent person using the Subpart P tables or designed by a registered professional engineer using site-specific geotechnical data.

## Related calculators

- [Excavation Sloping/Benching Setback Calculator](https://craftquantities.com/calculators/materials-quantities/excavation-sloping-setback-calculator/)
- [Footing Soil Bearing Pressure Checker](https://craftquantities.com/calculators/materials-quantities/footing-bearing-pressure-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/shoring-active-pressure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/shoring-active-pressure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `shoring-active-pressure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/shoring-active-pressure-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/shoring-active-pressure-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.