# Secant / Contiguous Pile Wall Overlap Calculator

> Check whether a bored pile wall's spacing produces true secant overlap or a contiguous gap between piles.

Page: https://craftquantities.com/calculators/heavy-civil/secant-pile-overlap-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Pile overlap (or gap): 0.5 ft overlap for Pile Diameter 2 ft and Center-to-Center Spacing 18 in, the page's opening figures; on the metric page, 0.6 m and 450 mm give 0.15 m overlap. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Pile Diameter | `pileDiameter` | 0.6 m | 2 ft | mm, cm, m, in, ft, yd; range 0.01–2 m |
| Center-to-Center Spacing | `centerToCenterSpacing` | 450 mm | 18 in | mm, cm, m, in, ft, yd; range 0.01–2 m |

- **Pile Diameter**: The diameter of each drilled pile.
- **Center-to-Center Spacing**: The distance between adjacent pile centers.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Pile overlap (or gap)** | 0.15 m overlap |
| Spacing-to-diameter ratio | 0.75 |

### US customary

| Result | Value |
|---|---|
| **Pile overlap (or gap)** | 0.5 ft overlap |
| Spacing-to-diameter ratio | 0.75 |

## How it is worked out

True secant configuration — adjacent piles physically overlap, forming a continuous water-resistant wall (assuming the secondary piles are cut into the primary piles as designed).

The working the page shows, in order: Spacing-to-diameter ratio; then pile overlap (or gap).

The method, derived in full:

- [Pile Capacity: Shaft Friction, End Bearing, and the Sign That Reverses](https://craftquantities.com/methodology/pile-capacity/): Why shaft friction and end bearing cannot simply be added at working load, why settling ground turns friction from a resistance into a load, and why ten piles do not carry ten times what one does.

What this calculation does not cover:

- This is a geometry check on the two numbers you type, not a wall design. It says nothing about pile capacity, embedment below formation level, wall stiffness, or the earth and water pressures the wall has to hold, and it does not stand in for a temporary works design.
- Verticality is not in the arithmetic. A bored pile drifts off plumb with depth, so a nominal overlap that holds at the top can be gone at the toe; the deeper the wall, the more design overlap it needs, and this does not tell you how much to add.
- It assumes every pile is full diameter and set exactly on its layout point. Setting-out error, casing or auger wander, and over- or under-break in the bore all eat into overlap, and none of them are modelled — the number is nominal, not as-built.
- Nothing here covers the concrete or the sequence: primary pile mix strength (the soft, firm or hard secant distinction), the window in which the secondary pile must be cut into the primary, reinforcement, or guide-wall setting-out. A geometrically valid overlap can still be undrillable.
- A positive overlap is not proof the wall will hold water. Sealing depends on joint quality, construction tolerance and any grouting or membrane treatment, and a contiguous wall — spacing at or beyond the pile diameter — needs a separate water-control measure whatever this returns.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Secant pile geometry: adjacent piles overlap when center-to-center spacing is less than the pile diameter; overlap distance = diameter minus spacing (a negative result indicates a gap, i.e. a contiguous rather than secant wall)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What's the difference between secant and contiguous pile walls?**

Secant piles physically overlap, forming a continuous barrier suitable for groundwater control, while contiguous piles are spaced with a small gap between them and don't seal against water. In a secant wall the primary and secondary piles interlock; a contiguous wall relies on the gap being small enough (or otherwise treated) to retain soil.

**What overlap amount is typically targeted?**

A common target is 100-150mm (4-6 in) of overlap for secant walls, though this varies by project specification and equipment tolerance — always check your project's structural design.

**Does this account for pile verticality tolerance?**

No — this is a nominal geometric check based on design spacing. Real drilled piles have some verticality tolerance over depth, so deeper walls typically need more design overlap margin to guarantee actual overlap is maintained at the base.

## Related calculators

- [Circular Pier / Cylinder Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/circular-pier-concrete-calculator/)
- [Drilled Pier Concrete Volume Calculator (Straight Shaft / Belled)](https://craftquantities.com/calculators/materials-quantities/drilled-pier-volume-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/secant-pile-overlap-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/secant-pile-overlap-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `secant-pile-overlap-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/secant-pile-overlap-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/secant-pile-overlap-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.