# Reinforced SRW Internal Sliding Check

> Sliding factors of safety at each geogrid level of a reinforced segmental wall and at its levelling pad, and the level where the margin is thinnest.

Page: https://craftquantities.com/calculators/heavy-civil/reinforced-wall-internal-sliding-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 2 published test vectors.

Governing sliding factor of safety: 1.97 (factor of safety) for Total Wall Height 15 ft, Vertical Spacing Between Reinforcement Levels 24 in and Reinforcement Length Into the Fill 10.5 ft, the page's opening figures; on the metric page, 4.5 m, 600 mm and 3.2 m give 1.99 (factor of safety). Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Wall Height | `wallHeight` | 4.5 m | 15 ft | mm, cm, m, in, ft, yd; range 1–12 m |
| Vertical Spacing Between Reinforcement Levels | `gridSpacing` | 600 mm | 24 in | mm, cm, m, in, ft, yd; range 0.2–1.2 m |
| Reinforcement Length Into the Fill | `reinforcedLength` | 3.2 m | 10.5 ft | mm, cm, m, in, ft, yd; range 0.6–12 m |
| Unit Weight of the Reinforced Mass | `massUnitWeight` | 1950 kg/m³ | 121.735 pcf | kgm3, pcf, lbyd3; range 1400–2400 kg/m³ |
| Uniform Surcharge Behind the Wall | `surcharge` | 12 kPa | 250.625 psf | pa, kpa, mpa, psi, psf, in_wc; range 0–50000 Pa |
| Retained Soil Friction Angle (degrees) | `soilFrictionAngle` | 32 | 32 | range 18–45 |
| Interface Friction Coefficient at the Grid | `gridFrictionCoefficient` | 0.6 | 0.6 | range 0.2–1 |
| Friction Coefficient at the Levelling Pad | `baseFrictionCoefficient` | 0.55 | 0.55 | range 0.2–1 |

- **Total Wall Height**: Height of the reinforced mass from the top of the levelling pad to the top of the wall.
- **Vertical Spacing Between Reinforcement Levels**: Uniform vertical spacing at which grid layers are placed up the wall.
- **Reinforcement Length Into the Fill**: Horizontal length of each grid layer, which is also the width of the reinforced block being checked.
- **Unit Weight of the Reinforced Mass**: Average density of the compacted reinforced fill together with the facing units it stands behind.
- **Uniform Surcharge Behind the Wall**: Uniformly distributed load carried on the retained soil behind the reinforced zone.
- **Retained Soil Friction Angle (degrees)**: Angle of internal friction of the retained soil behind the reinforced zone.
- **Interface Friction Coefficient at the Grid**: Coefficient of interaction for sliding along a grid layer, from the manufacturer's direct-shear testing.
- **Friction Coefficient at the Levelling Pad**: Coefficient for sliding of the whole wall across its levelling pad.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Governing sliding factor of safety** | 1.99 (factor of safety) |
| Factor of safety against sliding at the levelling pad | 1.99 (factor of safety) |
| Factor of safety at reinforcement level 1 | 2.42 (factor of safety) |
| Factor of safety at reinforcement level 2 | 2.74 (factor of safety) |
| Factor of safety at reinforcement level 3 | 3.16 (factor of safety) |
| Factor of safety at reinforcement level 4 | 3.73 (factor of safety) |
| Factor of safety at reinforcement level 5 | 4.54 (factor of safety) |
| Reinforcement levels in the wall | 7 levels |
| Driving thrust at the governing plane | 76.08 kN/m |
| Active earth pressure coefficient | 0.31 (Ka) |

### US customary

| Result | Value |
|---|---|
| **Governing sliding factor of safety** | 1.97 (factor of safety) |
| Factor of safety against sliding at the levelling pad | 1.97 (factor of safety) |
| Factor of safety at reinforcement level 1 | 2.4 (factor of safety) |
| Factor of safety at reinforcement level 2 | 2.71 (factor of safety) |
| Factor of safety at reinforcement level 3 | 3.13 (factor of safety) |
| Factor of safety at reinforcement level 4 | 3.69 (factor of safety) |
| Factor of safety at reinforcement level 5 | 4.5 (factor of safety) |
| Reinforcement levels in the wall | 7 levels |
| Driving thrust at the governing plane | 5,363.05 lbf/ft |
| Active earth pressure coefficient | 0.31 (Ka) |

- Confidence: medium.

## How it is worked out

The levelling pad governs: the whole wall slides before any single grid layer does. Levels are numbered from the base upward, and the factor rises as you go up because less mass sits above each successive plane.

The working the page shows, in order: Factor of safety against sliding at the levelling pad; Factor of safety at reinforcement level 1; Factor of safety at reinforcement level 2; Factor of safety at reinforcement level 3; Factor of safety at reinforcement level 4; Factor of safety at reinforcement level 5; Reinforcement levels in the wall; Driving thrust at the governing plane; Active earth pressure coefficient; then governing sliding factor of safety.

The method, derived in full:

- [Lateral Earth Pressure and the Wall That Resists It](https://craftquantities.com/methodology/lateral-earth-pressure/): Why one soil has three pressures that differ ninefold, why the resultant acts a third of the way up rather than halfway, and why water is what actually fails retaining walls.

What this calculation does not cover:

- Sliding only. Connection capacity, grid tensile rupture, pullout beyond the failure surface, bearing and global stability are separate checks this page does not perform.
- Assumes a level backslope, a uniform surcharge and a single reinforcement length at every level. A broken backslope or a truncated layout changes both the thrust and the resisting mass.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- NCMA Design Manual for Segmental Retaining Walls sets out the internal stability checks for a geogrid-reinforced SRW, of which sliding of the mass above a reinforcement level is one; connection strength and pullout are separate checks it also requires and this page does not perform
- Rankine active earth pressure, Ka = tan squared (45 degrees minus phi/2), with thrust on the back of the reinforced mass taken as 0.5 x Ka x gamma x h squared plus Ka x q x h for a uniform surcharge
- Sliding resistance at a reinforcement level is the weight of the mass above it times a coefficient of interaction from the geogrid manufacturer's direct-shear data — that is a tested interface property, not a soil friction angle, and it is entered here rather than derived

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why would a wall slide on a grid layer rather than at its base?**

Because a geogrid creates a plane through the fill where friction is lower than the fill's own. If that reduction is severe enough, a plane part way up the wall can be worse off than the pad even though it has less soil pushing on it, and the check has to be run at every level rather than only at the bottom.

**Why does the factor of safety fall as you go down the wall?**

The driving thrust grows with the square of the height above the plane while the resisting weight grows only linearly with it, so the ratio between them shrinks steadily with depth. That is why the lowest levels are always the ones listed here, and why a wall that passes at level five tells you nothing about level one.

**Does the surcharge matter more at the top or the bottom?**

Proportionally more at the top. A uniform surcharge adds thrust in proportion to the height above the plane, but it adds nothing at all to the reinforced mass resisting the slide, so it erodes the margin at a shallow plane faster than at a deep one. A wall that only just passes without one can fail at an upper level with it.

**Is this enough to design a reinforced wall?**

No — sliding is one of several internal checks and none of the external ones. Connection strength at the facing, tensile rupture of the grid, pullout beyond the failure surface, bearing pressure under the mass and global stability through the founding soils all have to be satisfied as well, and the manufacturer's tested data governs several of them.

## Related calculators

- [Retaining Wall Preliminary Stability Check](https://craftquantities.com/calculators/materials-quantities/retaining-wall-stability-calculator/)
- [Geogrid Reinforcement Layer Count Calculator](https://craftquantities.com/calculators/materials-quantities/geogrid-layer-count-calculator/)
- [Rankine Active Earth Pressure with Surcharge Calculator](https://craftquantities.com/calculators/materials-quantities/active-pressure-surcharge-calculator/)
- [Retaining Wall Drainage Gravel Calculator](https://craftquantities.com/calculators/auto-utility/retaining-wall-drainage-gravel-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/reinforced-wall-internal-sliding-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/reinforced-wall-internal-sliding-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `reinforced-wall-internal-sliding-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/reinforced-wall-internal-sliding-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/reinforced-wall-internal-sliding-calculator/