# Rational Method Peak Runoff Calculator

> Peak discharge from a small catchment by the rational method (Q = C i A), with the on-site and offsite areas each at its own runoff coefficient.

Page: https://craftquantities.com/calculators/heavy-civil/rational-method-peak-runoff-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 2 published test vectors.

Peak discharge: 1.49 ft³/s for On-Site Contributing Area 21530 sq ft, the page's opening figures; on the metric page, 2000 m² gives 0.0421 m³/s. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| On-Site Contributing Area | `onsiteArea` | 2000 m² | 21530 sq ft | m2, ft2, mm2, in2; range 1–200000 m² |
| On-Site Runoff Coefficient | `onsiteCoefficient` | 0.8 | 0.8 | range 0.05–0.98 |
| Offsite Contributing Area | `offsiteArea` | 1200 m² | 12920 sq ft | m2, ft2, mm2, in2; range 0–200000 m² |
| Offsite Runoff Coefficient | `offsiteCoefficient` | 0.35 | 0.35 | range 0.05–0.98 |
| Design-Storm Rainfall Intensity (mm/hr) | `rainfallIntensity` | 75 | 75 | range 5–300 |

- **On-Site Contributing Area**: Area inside the site boundary that drains to the point being sized.
- **On-Site Runoff Coefficient**: Fraction of rainfall on the site area that becomes surface runoff.
- **Offsite Contributing Area**: Area beyond the boundary whose water crosses onto the site and has to be carried through it.
- **Offsite Runoff Coefficient**: Runoff fraction for the surface beyond the boundary, which is rarely the same as the site's.
- **Design-Storm Rainfall Intensity (mm/hr)**: Average intensity of the design storm over the catchment's time of concentration (25.4 mm/hr is 1 in/hr).

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Peak discharge** | 0.0421 m³/s |
| Total contributing area | 3,200 m² |
| Area-weighted runoff coefficient | 0.63 (C) |
| Contribution from beyond the boundary | 0.01 m³/s |
| Share of the peak arriving from offsite | 20.79 % |

### US customary

| Result | Value |
|---|---|
| **Peak discharge** | 1.49 ft³/s |
| Total contributing area | 34,450 sq ft |
| Area-weighted runoff coefficient | 0.63 (C) |
| Contribution from beyond the boundary | 0.31 ft³/s |
| Share of the peak arriving from offsite | 20.79 % |

- Confidence: medium.

## How it is worked out

The Rational Method returns a peak flow and nothing else — no hydrograph, no volume, no timing. It is accepted for small catchments and routinely rejected above a size limit written into the local ordinance, so check that limit before using this figure in a submission.

The working the page shows, in order: Total contributing area; Area-weighted runoff coefficient; Contribution from beyond the boundary; Share of the peak arriving from offsite; then peak discharge.

The method, derived in full:

- [Stormwater, Runoff and the Water Balance](https://craftquantities.com/methodology/stormwater-and-water-balance/): Why a small catchment is designed for a more intense rainfall than a large one, why a detention basin can make things worse downstream, and why a rainwater tank delivers far less than annual rainfall times roof area.

What this calculation does not cover:

- Assumes uniform rainfall over the whole catchment for the full duration, and a single time of concentration for both areas.
- Gives no runoff volume, so it cannot size detention or infiltration storage — those need a hydrograph method.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- The Rational Method, Q = C x i x A, as adopted by local stormwater ordinances for small catchments; the runoff coefficients and the design-storm intensity belong to the reviewing jurisdiction and are entered here rather than supplied
- Intensity is read from the jurisdiction's intensity-duration-frequency curve at the design return period, for a storm duration equal to the catchment's time of concentration
- Worked in SI throughout — Q equals C times the intensity in metres per second times the area in square metres — then restated in the unit the visitor's market uses. No 1.008 or 1/360 shortcut factor is applied anywhere

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why keep the offsite area separate instead of adding it in?**

Because it almost never has the same surface. Lumping a grassed field in with a paved yard under one coefficient either overstates the field or understates the yard, and the area-weighted figure this page computes is what a reviewer expects to see. Keeping them apart also shows how much of the peak is arriving from land you do not control.

**How do I convert an intensity given in inches per hour?**

Multiply by 25.4, since an inch is 25.4 millimetres by definition. A 2 in/hr design storm is 50.8 mm/hr, and a 4 in/hr one is 101.6 mm/hr. The field on this page is in millimetres per hour so that the arithmetic behind it can stay in SI throughout.

**What storm duration should the intensity be read at?**

The catchment's time of concentration — the time water takes to travel from the hydraulically most remote point to the outlet. That is the duration at which the whole catchment is contributing at once, which is what produces the peak. Reading a shorter duration overstates the intensity and a longer one understates the peak.

**Can I use this to size a detention basin?**

No. A detention basin is sized by volume over time, and the Rational Method produces a single peak flow with no hydrograph behind it. Use it to size a pipe, an inlet or a channel that has to pass the peak, and move to a hydrograph method when the question becomes how much water arrives in total.

## Related calculators

- [Grassed Swale Capacity & Velocity Calculator](https://craftquantities.com/calculators/heavy-civil/grassed-swale-capacity-calculator/)
- [Storm Drain Pipe Slope Calculator](https://craftquantities.com/calculators/materials-quantities/storm-drain-slope-calculator/)
- [Culvert Pipe Length Calculator](https://craftquantities.com/calculators/heavy-civil/culvert-pipe-length-calculator/)
- [PICP Permeable Pavement Infiltration Storage Calculator](https://craftquantities.com/calculators/sustainability-compliance/picp-infiltration-storage-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/rational-method-peak-runoff-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/rational-method-peak-runoff-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `rational-method-peak-runoff-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/rational-method-peak-runoff-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/rational-method-peak-runoff-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.