# Pile Group Efficiency Calculator (Converse-Labarre)

> Estimate the reduction in per-pile capacity when piles are installed close together in a group, using the Converse-Labarre formula.

Page: https://craftquantities.com/calculators/heavy-civil/pile-group-efficiency-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Group efficiency factor: 0.727 (Eg) for Pile Diameter 16 in and Center-to-Center Spacing 4 ft, the page's opening figures; on the metric page, 400 mm and 1.2 m give 0.727 (Eg). Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Pile Diameter (d) | `pileDiameter` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0.01–1.5 m |
| Center-to-Center Spacing (s) | `pileSpacing` | 1.2 m | 4 ft | mm, cm, m, in, ft, yd; range 0.01–5 m |
| Number of pile rows m | `rows` | 3 | 3 | range 1–10 |
| Number of Columns (n) | `columns` | 3 | 3 | range 1–10 |

- **Pile Diameter (d)**: The diameter of each pile in the group.
- **Center-to-Center Spacing (s)**: The center-to-center spacing between adjacent piles.
- **Number of pile rows m**: The number of pile rows in the group.
- **Number of Columns (n)**: The number of pile columns in the group.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Group efficiency factor** | 0.727 (Eg) |
| θ = arctan(d/s) | 18.43 ° |

### US customary

| Result | Value |
|---|---|
| **Group efficiency factor** | 0.727 (Eg) |
| θ = arctan(d/s) | 18.43 ° |

- Confidence: medium.

## How it is worked out

The Converse-Labarre formula is a widely-used but empirical approximation — some geotechnical engineers consider group efficiency for friction piles in clay more reliably assessed with a block failure check instead, especially for closely-spaced groups.

The working the page shows, in order: θ = arctan(d/s); then group efficiency factor.

The method, derived in full:

- [Pile Capacity: Shaft Friction, End Bearing, and the Sign That Reverses](https://craftquantities.com/methodology/pile-capacity/): Why shaft friction and end bearing cannot simply be added at working load, why settling ground turns friction from a resistance into a load, and why ten piles do not carry ten times what one does.

What this calculation does not cover:

- The result is the Converse-Labarre per-pile efficiency and nothing else. It does not check block failure, where the piles and the soil between them fail as one mass — for friction piles in clay at close spacing that check often governs and gives the lower capacity, so it has to be run separately and the lower of the two used.
- The formula reads only diameter, spacing and grid size. It knows nothing about soil type, pile length or installation method, so it returns the same reduction for a driven pile in dense sand as for a bored pile in soft clay. Driven piles in loose to medium sand can reach an efficiency of 1.0 or higher because driving densifies the ground between them, and piles end-bearing on rock see essentially no group reduction — this calculator never returns either.
- This is a capacity reduction factor, not a foundation design. It applies no factor of safety or resistance factor, and it covers no settlement check — a pile group settles more than a single pile carrying the same load per pile, and settlement rather than capacity often governs the design.
- It assumes one rectangular grid of identical vertical piles at a single uniform spacing in both directions. Staggered or triangular layouts, raked piles, mixed pile diameters within the group, irregular group outlines and different row and column spacings are all outside the model.
- It applies no minimum spacing check. Buildable centre-to-centre spacing is set by the governing code and by piling rig tolerance, and this calculator will return a number for spacings closer than those permit — including spacings below one pile diameter, which is not a pile group at all.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Converse-Labarre pile group efficiency formula: Eg = 1 − θ x \[(n−1)m + (m−1)n\] / (90mn), where θ = arctan(d/s) in degrees, d is pile diameter, s is center-to-center spacing, m is the number of rows, and n is the number of columns

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do piles in a group have less capacity per pile than an isolated pile?**

Each pile's zone of soil stress overlaps with its neighbors' zones — closely-spaced piles effectively compete for the same soil resistance, reducing the group's total capacity below the simple sum of each pile's individual capacity.

**How is group capacity actually used?**

Multiply the group efficiency factor by (number of piles x individual pile capacity) to get the group's usable capacity — or compare that against the equivalent "block" capacity of the whole group treated as one large pier, and use whichever governs (is lower).

**Does wider spacing always mean better efficiency?**

Yes — efficiency approaches 100% as spacing increases relative to pile diameter, since the piles' stress zones stop overlapping — but wider spacing also means a bigger, more expensive pile cap and foundation footprint.

## Related calculators

- [Driven Pile Skin Friction Capacity Calculator (Alpha Method)](https://craftquantities.com/calculators/materials-quantities/driven-pile-skin-friction-calculator/)
- [Negative Skin Friction (Downdrag) Calculator](https://craftquantities.com/calculators/materials-quantities/negative-skin-friction-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/pile-group-efficiency-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/pile-group-efficiency-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `pile-group-efficiency-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/pile-group-efficiency-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/pile-group-efficiency-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.