# Pile Group Block Failure Calculator (Clay)

> Block-failure capacity of a pile group in clay, set beside the single piles' sum reduced by Converse-Labarre efficiency, and the smaller of the two.

Page: https://craftquantities.com/calculators/heavy-civil/pile-group-block-failure-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 3 published test vectors.

Block failure capacity (ultimate): 2,510 kips for Rows of Piles 3 and Piles in Each Row 3, the page's opening figures; on the metric page, 3 and 3 give 11,000 kN. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rows of Piles | `rows` | 3 | 3 | range 1–10 |
| Piles in Each Row | `columns` | 3 | 3 | range 1–10 |
| Centre-to-Centre Spacing | `spacing` | 1.2 m | 4 ft | mm, cm, m, in, ft, yd; range 0.3–6 m |
| Pile Diameter | `diameter` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0.1–2 m |
| Pile Length in the Clay (D) | `pileLength` | 15 m | 49 ft | mm, cm, m, in, ft, yd; range 1–60 m |
| Average Undrained Strength Along the Shaft (c̄u) | `shaftStrength` | 40 kPa | 835.417 psf | pa, kpa, mpa, psi, psf, in_wc; range 5000–300000 Pa |
| Undrained Strength at the Base (cu) | `baseStrength` | 60 kPa | 1253.13 psf | pa, kpa, mpa, psi, psf, in_wc; range 5000–500000 Pa |
| Ultimate Capacity of One Pile (0 to skip) | `singlePileCapacity` | 900 kN | 202.328 kip | n, kn, lbf, kip; range 0–50000000 N |

- **Rows of Piles**: The number of rows in the group.
- **Piles in Each Row**: The number of piles in each row.
- **Centre-to-Centre Spacing**: The distance between pile centres, the same in both directions.
- **Pile Diameter**: The pile's diameter, or the width of a square pile.
- **Pile Length in the Clay (D)**: The embedded length the block's sides shear along.
- **Average Undrained Strength Along the Shaft (c̄u)**: The clay's undrained shear strength averaged over the pile length.
- **Undrained Strength at the Base (cu)**: The clay's undrained strength at the level of the pile toes.
- **Ultimate Capacity of One Pile (0 to skip)**: One pile's ultimate capacity, shaft plus base, to compare the block against.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Block failure capacity (ultimate)** | 11,000 kN |
| Block width, out to out | 2.8 m |
| Block length, out to out | 2.8 m |
| Bearing capacity factor Nc | 9 |
| Shear round the block's sides | 6,720 kN |
| End bearing under the block | 4,233.6 kN |
| Converse-Labarre efficiency | 0.73 |
| Sum of the single piles | 8,100 kN |
| Sum reduced by the efficiency | 5,887.81 kN |
| The smaller of the two | 5,887.81 kN |

### US customary

| Result | Value |
|---|---|
| **Block failure capacity (ultimate)** | 2,510 kips |
| Block width, out to out | 9.33 ft |
| Block length, out to out | 9.33 ft |
| Bearing capacity factor Nc | 9 |
| Shear round the block's sides | 1,528.26 kips |
| End bearing under the block | 982.45 kips |
| Converse-Labarre efficiency | 0.73 |
| Sum of the single piles | 1,820.95 kips |
| Sum reduced by the efficiency | 1,323.63 kips |
| The smaller of the two | 1,323.63 kips |

- Confidence: medium.

## How it is worked out

The reduced sum of the single piles gives the smaller capacity; the block is stronger than the piles acting individually. Both figures are ultimate capacities. The working load follows from the factor of safety or the partial factors the design applies, and settlement of the group often governs before either is reached.

The working the page shows, in order: Block width, out to out; Block length, out to out; Bearing capacity factor Nc; Shear round the block's sides; End bearing under the block; Converse-Labarre efficiency; Sum of the single piles; Sum reduced by the efficiency; The smaller of the two; then block failure capacity (ultimate).

The method, derived in full:

- [Pile Capacity: Shaft Friction, End Bearing, and the Sign That Reverses](https://craftquantities.com/methodology/pile-capacity/): Why shaft friction and end bearing cannot simply be added at working load, why settling ground turns friction from a resistance into a load, and why ten piles do not carry ten times what one does.

What this calculation does not cover:

- Undrained, total-stress capacity of friction piles in clay in the short term. Long-term drained behaviour, piles in sand, and end-bearing piles on rock are different calculations.
- The block's weight and the weight of soil it replaces are taken to cancel, as the method conventionally does. A block founded in soft clay under a heavy cap needs that assumption checked.
- The Converse-Labarre efficiency knows only the pile diameter, the spacing and the grid, nothing about the soil or how the piles were installed. It is a screening figure from the foundation literature, not a design rule.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- Block failure of a pile group in clay (Terzaghi and Peck; Tomlinson and Woodward, Pile Design and Construction Practice): Q = 2(B + L) × D × c̄u + B × L × cu × Nc, where B and L are the group's plan dimensions out to out, D the pile length, c̄u the average undrained strength along the shaft and cu the strength at the base
- Skempton's bearing capacity factor for a rectangular base in clay: Nc = 5 × (1 + 0.2 D/B) × (1 + 0.2 B/L), with D/B taken no greater than 2.5, so Nc reaches 9 under a deep square block
- The Converse-Labarre group efficiency E = 1 − θ × \[(n − 1)m + (m − 1)n\] ÷ (90 × m × n), θ = arctan(d/s) in degrees, for m columns and n rows (Bowles, Foundation Analysis and Design)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is block failure?**

Piles close together share the soil between them, and under load the whole group — piles, cap and the enclosed soil — can plunge as one large pier. Its capacity is the shear round the block's perimeter plus end bearing across its base. Where the piles are close and the group is large, that is less than the reduced sum of the single piles, and it is the check that governs.

**Why run both checks?**

Because either can be the smaller. At wide spacings the piles act individually and the reduced sum governs; close together, the block does. On the soft-ground guide's nine 400 mm (16 in) piles at 1.2 m (3 ft 11 in) centres, 15 m (49 ft) long in clay at 40 kPa (835 psf), the block carries about 10,950 kN (2,460 kip) and the reduced sum of piles about 5,890 kN (1,320 kip), so the piles govern there.

**Why does the block use the full undrained strength on its sides?**

Because the block's sides are soil shearing against soil, not a pile surface against soil. A single pile's shaft takes an adhesion factor for the smear and remoulding at its face; the block's perimeter runs through undisturbed clay between the outer piles.

**What is Nc, and why does it stop at 9?**

Skempton's bearing capacity factor for a base in clay. It grows with depth up to a depth of two and a half times the width, then stays level, and it is higher for a square than for a long strip — 9 under a deep square block, 7.5 under a deep strip.

## Related calculators

- [Pile Group Efficiency Calculator (Converse-Labarre)](https://craftquantities.com/calculators/heavy-civil/pile-group-efficiency-calculator/)
- [Driven Pile Skin Friction Capacity Calculator (Alpha Method)](https://craftquantities.com/calculators/materials-quantities/driven-pile-skin-friction-calculator/)
- [Negative Skin Friction (Downdrag) Calculator](https://craftquantities.com/calculators/materials-quantities/negative-skin-friction-calculator/)
- [Shallow Foundation Bearing Capacity Calculator (Vesic Factors)](https://craftquantities.com/calculators/materials-quantities/terzaghi-bearing-capacity-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/pile-group-block-failure-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/pile-group-block-failure-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `pile-group-block-failure-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/pile-group-block-failure-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/pile-group-block-failure-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.