# Dewatering Well Yield Calculator (Dupuit-Forchheimer)

> Estimate the steady-state pumping rate a dewatering well can sustain in an unconfined aquifer, using the Dupuit-Forchheimer equation.

Page: https://craftquantities.com/calculators/heavy-civil/dewatering-well-yield-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-31, 2 published test vectors.

Estimated well yield: 44.7 gal/min for Hydraulic Conductivity 0, the page's opening figures; on the metric page, 0 gives 165 L/min. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Hydraulic Conductivity (K, m/s) | `hydraulicConductivity` | 0.0001 | 0.0001 | range 1e-7–0.01 |
| Saturated Thickness at Outer Radius (h1) | `outerSaturatedThickness` | 10 m | 33 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Saturated Thickness at the Well (h2) | `wellSaturatedThickness` | 7 m | 23 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Outer Radius (r1) | `outerRadius` | 50 m | 165 ft | mm, cm, m, in, ft, yd; range 0.01–1000 m |
| Well Radius (r2) | `wellRadius` | 15 cm | 6 in | mm, cm, m, in, ft, yd; range 0.01–1 m |

- **Hydraulic Conductivity (K, m/s)**: The aquifer's hydraulic conductivity.
- **Saturated Thickness at Outer Radius (h1)**: The undisturbed saturated aquifer thickness far from the well.
- **Saturated Thickness at the Well (h2)**: The remaining saturated thickness right at the pumping well, after drawdown.
- **Outer Radius (r1)**: The radius at which h1 is measured (often the radius of influence).
- **Well Radius (r2)**: The radius of the pumping well itself.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Estimated well yield** | 165 L/min |
| Equivalent in m³/day | 238.3 m³/day |
| Equivalent in US gallons per minute | 43.72 gpm |

### US customary

| Result | Value |
|---|---|
| **Estimated well yield** | 44.7 gal/min |
| Equivalent in m³/day | 243.51 m³/day |
| Equivalent in US gallons per minute | 44.67 gpm |

- Confidence: medium.

## How it is worked out

This is a steady-state estimate assuming a fully penetrating well in a homogeneous, isotropic unconfined aquifer — real dewatering systems are affected by partial penetration, aquifer boundaries, and non-steady flow, and should be verified with an actual pump test.

The working the page shows, in order: Equivalent in m³/day; Equivalent in US gallons per minute; then estimated well yield.

The method, derived in full:

- [Seepage, Drawdown and Dewatering](https://craftquantities.com/methodology/seepage-and-dewatering/): Why permeability varies over ten orders of magnitude and therefore dominates every seepage answer, why the radius of influence is an empirical fudge rather than a measurement, and why dewatering settles the neighbours.

What this calculation does not cover:

- The equation covers one fully penetrating well pumping on its own. It does not add the drawdown cones of neighbouring wells or wellpoints, so it cannot tell you how many wells an excavation needs or how far apart to set them — in a ring or a line each well delivers less than this figure.
- Steady state only, in a homogeneous, isotropic, unconfined aquifer. There is no time in the arithmetic, so the higher rate while the cone is still developing and the total volume pumped over the job both sit outside it, as do partial penetration, layered or anisotropic ground, confined and leaky aquifers, and any recharge or no-flow boundary such as a river, a cut-off wall or bedrock.
- This is a planning-level flow estimate, not a dewatering design and not a pump specification. Screen entrance velocity, filter pack capacity, drawdown available to the pump, suction lift limits, friction losses in the header and discharge run, and standby capacity are all separate calculations, and the yield itself should be confirmed by a pump test before plant is ordered.
- Nothing here covers the consequences of lowering the water table: settlement of shallow-founded structures and services inside the drawdown cone, migration of fines and piping into the well, or the discharge consent and abstraction licensing the pumped water needs. Where drawdown reaches a neighbour's property, an abstraction, or compressible ground, that is a geotechnical engineer's assessment, not a page of arithmetic.
- Yield is directly proportional to the hydraulic conductivity you type, and K in natural ground varies by orders of magnitude over short distances and directions. The result carries no uncertainty band around that, and the K box is read as metres per second whichever measurement system the page is set to.

A professional must decide:

- Nothing here covers the consequences of lowering the water table: settlement of shallow-founded structures and services inside the drawdown cone, migration of fines and piping into the well, or the discharge consent and abstraction licensing the pumped water needs. Where drawdown reaches a neighbour's property, an abstraction, or compressible ground, that is a geotechnical engineer's assessment, not a page of arithmetic.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Dupuit-Forchheimer equation for steady radial flow to a well in an unconfined aquifer: Q = pi x K x (h1² − h2²) / ln(r1/r2)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the Dupuit-Forchheimer equation used for?**

It's a classic well hydraulics formula for estimating steady-state groundwater flow to a pumping well in an unconfined aquifer, widely used for early dewatering and water supply well planning.

**Why does the answer depend on ln(r1/r2) rather than a simple ratio?**

Radial groundwater flow toward a well isn't uniform — flow lines converge, and the logarithmic term correctly captures how the hydraulic gradient increases as flow approaches the well, a signature feature of radial flow problems.

**How accurate is this compared to real dewatering performance?**

It's a reasonable planning-level estimate for a single well in ideal conditions — real systems (especially well fields with multiple wells) benefit from an actual pump test and, for complex sites, numerical groundwater modeling.

## Related calculators

- [Darcy's Law Seepage Flow Rate Calculator](https://craftquantities.com/calculators/materials-quantities/darcys-law-seepage-calculator/)
- [Wellpoint Dewatering Radius of Influence Calculator (Sichardt)](https://craftquantities.com/calculators/materials-quantities/wellpoint-radius-influence-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/dewatering-well-yield-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/dewatering-well-yield-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `dewatering-well-yield-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/dewatering-well-yield-calculator.json

---
Source: https://craftquantities.com/calculators/heavy-civil/dewatering-well-yield-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.