# Watts to Amps Calculator (120 V)

> Convert an appliance wattage into the current it draws on a 120 V circuit, for breaker and cable checks.

Page: https://craftquantities.com/calculators/electrical/watts-to-amps-120v-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Current draw: 12.5 A for Power 1500, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Power (W) | `watts` | 1500 | 1500 | range 0–20000 |

- **Power (W)**: The appliance's rated power in watts.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Current draw** | 12.5 A |
| Conversion factor applied | 0.01 A per W |

### US customary

| Result | Value |
|---|---|
| **Current draw** | 12.5 A |
| Conversion factor applied | 0.01 A per W |

## How it is worked out

I = P ÷ V at 120 V single phase. For a continuous load, compare the answer against 80% of the breaker rating rather than the full rating.

The working the page shows, in order: Conversion factor applied; then current draw.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- This is a unit conversion, not a load calculation. It gives what one appliance draws in isolation and accounts for nothing else already on the circuit, no diversity or demand factors, and no service-level total. Sizing a branch circuit, feeder or panel needs a full load calculation to the code in force where you are.
- The division treats the figure you enter as though voltage and current were in phase. On a motor, compressor, LED driver or switch-mode supply the current the supply actually has to deliver is higher than watts divided by 120, by the reciprocal of the power factor. Where the rating plate gives a VA figure, enter that one instead.
- Starting current is excluded. A motor or compressor can pull several times its running current for the first moments after switch-on, and that surge is what governs breaker curve choice and nuisance tripping. Nothing in this result reflects it.
- The arithmetic assumes exactly 120 V at the outlet. Delivered voltage sags under load and with distance from the transformer, and a constant-power load draws proportionally more current as the voltage falls. No voltage drop along the run is calculated here.
- No conductor is sized by this figure. Ampacity depends on the insulation temperature rating, ambient temperature, and how many current-carrying conductors share a raceway or cable, and the continuous-load uplift cited in the sources is not applied to the answer either. The comparison against 80% of the breaker rating is left for you to make.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Rearranged Ohm's law: I = P / V
- NEC 210.20(A) sizes the overcurrent device at 125% of a continuous load, and 210.19(A)(1) does the same for the conductor — which is the same rule read the other way round, as the familiar 80% ceiling on the breaker rating

The site's pages for the documents these name:

- [National Electrical Code (NFPA 70)](https://craftquantities.com/standards/nfpa/nec/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How much of a 15 A circuit can I actually use?**

For a continuous load — one running three hours or more — the usual limit is 80% of the breaker rating, so 12 A on a 15 A circuit, or about 1,440 W at 120 V. That is why a 1,500 W heater is awkward on a 15 A circuit even though the arithmetic says it fits.

**Does this cover starting current?**

No. A motor can pull several times its running current while it comes up to speed. That surge rarely changes the cable size, because it is too brief to heat the conductor, but it does influence breaker type and can cause nuisance tripping on a device with a fast magnetic response.

**What if the appliance is rated in VA rather than watts?**

Use the VA figure directly for current calculations — it is already volts times amps. Watts is the smaller number on an inductive load, and using it would understate the current the supply has to deliver.

## Related calculators

- [Amps to Watts Calculator (120 V)](https://craftquantities.com/calculators/electrical/amps-to-watts-120v-calculator/)
- [Watts, Amps and kVA Calculator (Any Voltage, AC or DC)](https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/)
- [Electrical Circuit Load Calculator](https://craftquantities.com/calculators/electrical/electrical-load-calculator/)
- [Amperage to Wire Gauge Calculator](https://craftquantities.com/calculators/electrical/amperage-to-wire-gauge-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/watts-to-amps-120v-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/watts-to-amps-120v-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `watts-to-amps-120v-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/watts-to-amps-120v-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/watts-to-amps-120v-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.