# Ohm's Law Calculator

> Enter voltage and resistance to get the current and power that follow from Ohm's Law.

Page: https://craftquantities.com/calculators/electrical/ohms-law-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Current: 3 A (current) for Voltage 12 and Resistance 4, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Voltage (V) | `voltage` | 12 | 12 | range 0–500 |
| Resistance (Ω) | `resistance` | 4 | 4 | range 0.01–100000 |

- **Voltage (V)**: The voltage across the circuit or component.
- **Resistance (Ω)**: The resistance of the circuit or component, in ohms.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Current** | 3 A (current) |
| Power | 36 W |
| Voltage | 12 V |
| Resistance | 4 Ω |

### US customary

| Result | Value |
|---|---|
| **Current** | 3 A (current) |
| Power | 36 W |
| Voltage | 12 V |
| Resistance | 4 Ω |

## How it is worked out

The working the page shows, in order: Power; Voltage; Resistance; then current.

The method, derived in full:

- [Photovoltaic Arrays, Inverters and Low-Voltage Runs](https://craftquantities.com/methodology/photovoltaic-and-low-voltage/): Why a solar string is limited by the coldest morning rather than the hottest day, why an array deliberately exceeds its inverter's rating, and why a small shadow can suppress a whole string.

What this calculation does not cover:

- This is not a load calculation and not a circuit design. It returns the current a fixed resistance draws at a given voltage, and says nothing about conductor ampacity, derating for ambient temperature or conduit fill, overcurrent device sizing, or whether the circuit is compliant.
- The model assumes a purely resistive load. On an AC circuit with motors, transformers, LED drivers or switch-mode supplies the current is set by impedance rather than plain resistance, and the power figure is apparent power in volt-amps, not watts, wherever the power factor is below 1.
- Resistance is taken as a fixed number. Conductor, element and filament resistance rise with temperature and terminations add their own, so a cold ohmmeter reading understates the operating resistance and the current shown will run high against what the circuit actually draws hot.
- Nothing is subtracted for the supply run. The voltage you enter is assumed to appear across the resistance itself, so on a long circuit the load sees less than that and draws proportionally less current than the figure here.
- The calculator prints whatever the arithmetic gives, including the fault-level current a very low resistance produces at mains voltage. It is not a short-circuit, interrupting-rating or arc-flash study, and it does not check that the current or power it reports is survivable for the conductors, the device or the person working on it.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Ohm's Law: V = I x R. Power equation: P = V x I. Both are exact, universal physics relationships, not rules of thumb.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What if I know current and resistance instead of voltage?**

Multiply them, V = I x R, and enter that voltage: this version solves from voltage and resistance for current and power, the most common starting point for wire/circuit planning. You can also use the tool iteratively.

**Is this exact or an approximation?**

Exact — Ohm's Law and the power equation are fundamental, universal physics relationships for resistive circuits, not empirical rules of thumb.

**Does this work for AC circuits with reactive loads?**

This simple form applies directly to purely resistive circuits (most household loads like heaters and incandescent bulbs). Circuits with significant inductance or capacitance (motors, some electronics) need impedance (Z) instead of plain resistance for accurate results.

## Related calculators

- [Electrical Circuit Load Calculator](https://craftquantities.com/calculators/electrical/electrical-load-calculator/)
- [Landscape Lighting Wire Calculator](https://craftquantities.com/calculators/electrical/landscape-lighting-wire-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/ohms-law-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/ohms-law-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `ohms-law-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/ohms-law-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/ohms-law-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.