# Generator Fuel Runtime Calculator

> Estimate how long a generator will run on a tank of fuel at a given load.

Page: https://craftquantities.com/calculators/electrical/generator-fuel-runtime-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-02, 2 published test vectors.

Estimated runtime: 6.67 hours for Fuel Tank Capacity 5 gal and Fuel Consumption Rate 0.75 gal/hr, the page's opening figures; on the metric page, 18.93 L and 2.84 L/hr give 6.67 hours. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Fuel Tank Capacity | `tankGallons` | 18.9271 L | 5 gal | l, gal, m3, ft3, yd3; range 1.89271–757.082 L |
| Fuel Consumption Rate | `fuelConsumptionGph` | 2.83906 L/hr | 0.75 gal/hr | lph, galph; range 0.378541–75.7082 L/hr |

- **Fuel Tank Capacity**: The generator's fuel tank size.
- **Fuel Consumption Rate**: Check the manufacturer's fuel consumption chart at your expected load percentage.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Estimated runtime** | 6.67 hours |

### US customary

| Result | Value |
|---|---|
| **Estimated runtime** | 6.67 hours |

- Confidence: medium.

## How it is worked out

Actual runtime varies with load percentage, fuel type, temperature, and altitude — check your specific generator's published fuel consumption chart at your actual expected load for a more precise figure.

The method, derived in full:

- [Capacity, Duty Cycle and Dose](https://craftquantities.com/methodology/capacity-duty-cycle-and-dose/): Why a lightly loaded generator wastes fuel and damages itself, why a propane tank can be full and still starve an appliance in cold weather, and why a bigger softener uses less salt per litre treated.

What this calculation does not cover:

- Treats the burn rate as constant for the whole run. Real load moves as pumps, fridges and heaters cycle, so this holds only if the rate you entered is the average across the run rather than the figure at one load point.
- Assumes every drop in the tank reaches the engine. Fuel pickups sit above the tank floor, low-fuel cut-out and surging arrive before a tank is dry, and a propane or LPG vessel is filled to a working fraction of its nameplate size — usable fuel is always less than stated capacity.
- No derate for site or engine condition. Altitude, intake air temperature, fuel type and a worn or poorly serviced engine all move consumption away from the manufacturer's chart, which is measured on a new set under test conditions.
- This is not a sizing or load calculation. It does not check that the generator can carry the load you intend to put on it, and it cannot tell whether the burn rate you entered matches that load — read the rate off the consumption chart at the load percentage you will actually run.
- Ignores the stops a long run needs. Oil-level checks and oil-change intervals on portable sets arrive well before a large tank empties, and refuelling means shutting the engine down and letting it cool. The hours here are fuel-limited, not the hours the machine will run unattended.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.
- Gas: pipe sizing, appliance connection and testing are for a registered or licensed gas fitter.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Runtime (hours) = fuel tank capacity (gallons) / fuel consumption rate (gallons per hour) at the expected load

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does load percentage affect fuel consumption so much?**

An engine burns noticeably more fuel per hour the harder it works — running a generator near its full rated capacity can use significantly more fuel per hour than running it at half load, even though it's the same generator.

**Should I run a generator at 100% load for best fuel efficiency?**

No — running continuously at 100% load stresses the generator and shortens its lifespan. Most manufacturers recommend sizing a generator so your typical load sits comfortably below its maximum rating (see the Generator Sizing Calculator), not running it at its limit for extended periods.

**Does this apply to natural gas or large propane tank standby generators?**

The same runtime-per-fuel-volume math applies, but standby generators connected to a home's natural gas line effectively have unlimited runtime, and a large propane tank's capacity (often in hundreds of gallons) should be used instead of a small portable tank size.

## Related calculators

- [Generator Sizing Calculator](https://craftquantities.com/calculators/electrical/generator-sizing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/generator-fuel-runtime-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/generator-fuel-runtime-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `generator-fuel-runtime-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/generator-fuel-runtime-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/generator-fuel-runtime-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.