# Extension Cord Gauge Calculator

> Find the thinnest extension cord gauge rated for your tool's amp draw that also keeps voltage drop under 3% over the cord length.

Page: https://craftquantities.com/calculators/electrical/extension-cord-gauge-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-31, 5 published test vectors.

Recommended cord gauge: 14 AWG for Cord Length 49 ft, the page's opening figures; on the metric page, 15 m gives 14 AWG. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Cord Length | `cordLength` | 15 m | 49 ft | mm, cm, m, in, ft, yd; range 0.01–60 m |
| Tool/Device Amp Draw | `currentAmps` | 10 | 10 | range 0.5–20 |
| Voltage | `circuitVoltage` | 120 V | 120 V | `120`, `240` |

- **Cord Length**: The total length of extension cord you plan to use.
- **Tool/Device Amp Draw**: The rated amp draw of what you're plugging in.
- **Voltage**: The nominal outlet voltage.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended cord gauge** | 14 AWG |
| Voltage drop at recommended gauge | 2.57 % |

### US customary

| Result | Value |
|---|---|
| **Recommended cord gauge** | 14 AWG |
| Voltage drop at recommended gauge | 2.56 % |

## How it is worked out

The working the page shows, in order: Voltage drop at recommended gauge; then recommended cord gauge.

The method, derived in full:

- [Voltage Drop and Conductor Sizing](https://craftquantities.com/methodology/voltage-drop-and-conductor-sizing/): Why the run length doubles, why a 12 V circuit suffers a hundred times the percentage loss of a 120 V one, and why ampacity answers a different question entirely.

What this calculation does not cover:

- The ampacity table is a fixed free-air rating for copper cord with two current-carrying conductors. Nothing here derates for a cord left coiled or wound on a reel, bundled with other cords, run under insulation or a rug, or used in high ambient heat — all of which cut how much current the cord can carry before it overheats.
- This sizes a cord; it is not a branch-circuit load calculation and not a code sign-off. It says nothing about whether the circuit behind the outlet can supply the current, whether the breaker and receptacle are rated for it, whether the load counts as continuous, or whether GFCI protection is required for the location.
- Only a single continuous run of copper in 16, 14, 12 or 10 AWG is modelled. Aluminium and copper-clad conductors, 18 AWG cords, the resistance of every plug and coupler where cords are joined end to end, and the voltage already lost in the building wiring upstream of the outlet are all excluded — so the real drop at the tool is worse than the figure shown, and more so the more couplers are in the run.
- The amp figure is treated as a steady running current. Motor inrush at startup is several times nameplate and is not modelled, so a cord that clears the 3% check can still leave a compressor, pump or large saw bogging down or tripping on start.
- The 3% drop figure is a working rule of thumb for cords, not a code limit, and the ampacity data is North American. On a 230/240 V supply outside NEC territory, cords are sized in mm² under local rules and the AWG answer here does not carry across. Cord construction is also outside the model — jacket type, wet and outdoor rating, temperature rating and listing for the use are not checked, and two cords of the same gauge are not interchangeable on those grounds.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Standard single-phase voltage drop formula: Vdrop = (2 x K x length in ft x amps) / circular mils, K=12.9 for copper — the same physics used to size branch-circuit wiring, applied here to cord length
- 3% voltage drop is a widely used comfort threshold for extension cords to avoid overheating and underpowered tools
- NEC Table 400.5(A)(1), allowable ampacity for flexible cords with 2 current-carrying conductors: 16 AWG 13 A, 14 AWG 18 A, 12 AWG 25 A, 10 AWG 30 A — the safety limit, checked before voltage drop

The site's pages for the documents these name:

- [National Electrical Code (NFPA 70)](https://craftquantities.com/standards/nfpa/nec/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why not just always use the thickest cord?**

Thicker (lower-gauge) cords are heavier, stiffer, and more expensive — this finds the thinnest cord that's still safe and efficient for your specific length and load, rather than over-specifying.

**What happens if I use a gauge that's too thin?**

Excess voltage drop makes motorized tools run hotter, weaker, and less efficiently, and can cause the cord itself to heat up under sustained load — a real fire risk with heavy-draw tools on long, thin cords.

**Does cord length include the tool's own built-in cord?**

No — this is for the extension cord only. Add the extension cord's length to any other extension cords used in series, but the tool's own short cord is usually negligible for this calculation.

## Related calculators

- [Wire Gauge Voltage Drop Calculator (Copper or Aluminum, AWG to 1,000 kcmil)](https://craftquantities.com/calculators/electrical/wire-gauge-voltage-drop-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/extension-cord-gauge-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/extension-cord-gauge-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `extension-cord-gauge-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/extension-cord-gauge-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/extension-cord-gauge-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.