# AWG to mm² Wire Size Calculator

> Convert American Wire Gauge to a metric conductor cross-section and back, with the nearest standard size in the other system.

Page: https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-11, 5 published test vectors.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Convert | `direction` | AWG → mm² | AWG → mm² | `awg-to-mm2`, `mm2-to-awg` |
| AWG size | `gauge` | 6 AWG | 6 AWG | `18`, `16`, `14`, `12`, `10`, `8`, `6`, `4`, `3`, `2`, `1`, `0`, `-1`, `-2`, `-3` |
| Conductor cross-section (mm²) | `areaMm2` | 16 | 16 | range 0.1–500 |

- **Convert**: Which way round the conversion runs.
- **AWG size**: The gauge on the cable jacket or the drawing.
- **Conductor cross-section (mm²)**: The metric conductor size, as printed on the cable or given in the specification.

`gauge` applies only when `direction` is `awg-to-mm2`.
`areaMm2` applies only when `direction` is `mm2-to-awg`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Conductor cross-section** | 13.3 mm² |
| Conductor diameter | 4.12 mm |
| Nearest standard metric size | 16 mm² |
| Nearest metric size that is not smaller | 16 mm² |
| Difference from that size | 20.28 % |

### US customary

| Result | Value |
|---|---|
| **Conductor cross-section** | 13.3 mm² |
| Conductor diameter | 0.16 in |
| Nearest standard metric size | 0.02 in² |
| Nearest metric size that is not smaller | 0.02 in² |
| Difference from that size | 20.28 % |

## How it is worked out

6 AWG is 13.30 mm². The geometry is exact — AWG is a defined ratio series — but no metric size lands on it, which is why both the nearest size and the nearest size that is not smaller are given.

The working the page shows, in order: Conductor diameter; Nearest standard metric size; Nearest metric size that is not smaller; Difference from that size; then conductor cross-section.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- An exact equivalent almost never exists, so every use of this number is a substitution, and substitution is an ampacity decision rather than an arithmetic one. Insulation temperature rating, installation method, ambient temperature, conduit fill and the rating of the terminals all bear on whether a size that matches on area is acceptable in a particular circuit.
- The two systems' standard sizes interleave rather than align. 6 AWG sits between 13 and 16 mm², 4 AWG between 21 and 25 mm² — so a designer working to one standard and buying to the other is always choosing to round up or down, and rounding down is the direction that removes margin.
- Nothing here checks voltage drop. Two conductors of the same area have the same resistance per metre whatever they are called, but the run length, load and acceptable drop decide the size at least as often as ampacity does, and on a long run they decide it outright.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-11):

- AWG is defined geometrically: 4/0 is 0.4600 in and 36 AWG is 0.0050 in, with 39 equal ratio steps between them, so diameter = 0.005 in × 92^((36 − n)/39)
- NEC Chapter 9, Table 8 (conductor properties) gives the same areas to three significant figures: 12 AWG = 3.31 mm², 6 AWG = 13.3 mm², 4/0 AWG = 107 mm²
- IEC 60228 nominal cross-sectional areas for standard metric conductors: 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400 mm²

The site's pages for the documents these name:

- [National Electrical Code (NFPA 70)](https://craftquantities.com/standards/nfpa/nec/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is there no metric size that matches my gauge?**

Because the two systems were built from different starting points and never reconciled. AWG is a geometric series — 39 equal ratio steps between 36 AWG at 0.005 in and 4/0 at 0.46 in — while the metric sizes are a preferred-number series chosen for round cross-sections. They interleave. 6 AWG is 13.3 mm², which sits between the standard 10 and 16, and no amount of arithmetic will make it land on either.

**Should I round up or down when substituting?**

Up, unless someone qualified has checked the circuit and decided otherwise. This page picks the size that is not smaller for exactly that reason. Rounding down removes margin from a conductor whose size was set by ampacity or voltage drop, and the shortfall does not announce itself — the circuit works, warm, until the day the load is at its maximum on a hot afternoon.

**Why do gauge numbers get smaller as the wire gets thicker?**

It is a drawing count rather than a measurement. The number originally recorded how many times the wire had been pulled through successively smaller dies, so more passes meant a thinner wire and a higher number. When the series ran past its zero it kept going with 1/0, 2/0, 3/0 and 4/0 — spoken as "one aught" and so on — each thicker than the last.

**Is the area in NEC Table 8 the same as the area here?**

Yes, to the precision the table prints. Table 8 gives 3.31 mm² for 12 AWG and 13.3 mm² for 6 AWG, which are these figures rounded to three significant figures. The table also carries circular mils, stranded diameters and resistance per thousand feet, and those are the columns to use for a voltage-drop calculation rather than the area alone.

**Does equal area mean equal ampacity?**

No, and this is the single most important thing on the page. Ampacity depends on the insulation's temperature rating, how the cable is installed, the ambient temperature, how many current-carrying conductors share the raceway, and what the terminals at each end are rated for. Two conductors identical in cross-section can have quite different permitted currents under NEC 310.16 and under IEC installation tables, and the two standards do not even define the reference conditions the same way.

**What happens above 4/0?**

The gauge series stops and North American practice switches to thousands of circular mils — 250 kcmil, 350 kcmil, 500 kcmil and upward. A circular mil is the area of a circle one thousandth of an inch across, so 250 kcmil is about 127 mm². This page covers the gauge range only and says so rather than extrapolating a series that has ended.

## Related calculators

- [Amperage to Wire Gauge Calculator](https://craftquantities.com/calculators/electrical/amperage-to-wire-gauge-calculator/)
- [Wire Gauge to Amperage Calculator](https://craftquantities.com/calculators/electrical/wire-gauge-to-amperage-calculator/)
- [Wire Gauge Voltage Drop Calculator (Copper or Aluminum, AWG to 1,000 kcmil)](https://craftquantities.com/calculators/electrical/wire-gauge-voltage-drop-calculator/)
- [Cable Voltage Drop Calculator (mm², Copper or Aluminium)](https://craftquantities.com/calculators/electrical/cable-voltage-drop-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/awg-to-mm2-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/awg-to-mm2-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `awg-to-mm2-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/awg-to-mm2-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/awg-to-mm2-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.