# Appliance Energy Cost Calculator

> Estimate the annual electricity cost of running an appliance based on its wattage and daily usage.

Page: https://craftquantities.com/calculators/electrical/appliance-energy-cost-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Appliance Wattage | `wattage` | 1500 | 1500 | range 1–20000 |
| Hours Used per Day | `hoursPerDay` | 2 | 2 | range 0.1–24 |
| Electricity Rate ($ per kWh) | `costPerKwh` | blank (your own rate) | blank (your own rate) | range 0.01–50 |

- **Appliance Wattage**: The device's rated power draw.
- **Hours Used per Day**: The average daily runtime.
- **Electricity Rate ($ per kWh)**: Your local electricity rate.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Energy used per year** | 1,100 kWh |
| Daily energy use | 3 kWh |

### US customary

| Result | Value |
|---|---|
| **Energy used per year** | 1,100 kWh |
| Daily energy use | 3 kWh |

- Confidence: medium.
- Withheld until you enter: Electricity Rate ($ per kWh). The site publishes no prices.

## How it is worked out

The working the page shows, in order: Daily energy use; then energy used per year.

The method, derived in full:

- [Break-Even, Payback and Comparing Costs Over Time](https://craftquantities.com/methodology/break-even-payback-and-life-cycle-cost/): Why simple payback is the weakest measure in common use, why two options with different lifespans cannot be compared on total cost, and why recouping 70% of a renovation at resale is a loss rather than a return.

What this calculation does not cover:

- This is a running-cost estimate, not a load calculation. Nothing here checks whether the circuit, breaker or conductors can carry the appliance — that is a separate calculation under the code in force where you are, and a 20,000 W entry returns a cost with no comment at all on the supply feeding it.
- The model assumes the appliance draws the entered wattage steadily for every hour entered. Anything that cycles or modulates — a refrigerator, freezer, heat pump, inverter-driven washer — spends most of its running time below the nameplate figure, and you have to convert that duty cycle into equivalent full-load hours yourself before entering it. Plate watts against plugged-in hours overstates a fridge several times over.
- Standby and off-mode draw is not counted. The hours entered are running hours, so the watts a television, microwave clock or charger pulls for the rest of the day sit outside the calculation entirely, and across a whole house those form a load of their own.
- One flat rate is applied to every kilowatt-hour of the year. Standing or daily supply charges, tiered blocks, time-of-use and seasonal rates, taxes and levies, and any price change during the year are all outside the model — use your bill's effective rate (total charges divided by total kWh) if your tariff is not flat. The currency symbol is a label on your own number; nothing here converts between currencies.
- The same daily runtime is applied to all 365 days. A heater, air conditioner, pool pump or dehumidifier runs on a season rather than on an average day, so for those loads the annual figure is only as good as the year-round average hours you fed it.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Annual cost = (wattage / 1000) x hours used per day x 365 x cost per kWh

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Is nameplate wattage the same as actual average power draw?**

Not always — nameplate wattage is often the maximum or peak draw. Appliances with compressors, variable-speed motors, or standby modes (fridges, HVAC, some electronics) use less than their peak rating on average, so a 'kill-a-watt' style plug meter gives a more accurate real-world reading.

**How do I find my electricity rate if I have tiered or time-of-use pricing?**

Use your average effective rate (total electric charges divided by total kWh used) from a recent bill as a reasonable approximation if your plan has complex tiered or time-of-use pricing.

**Is this useful for deciding whether to replace an old appliance?**

Yes — comparing this estimate for an old, inefficient appliance against a newer ENERGY STAR-rated model's lower wattage can help estimate the payback period on an upgrade.

## Related calculators

- [Electrical Circuit Load Calculator](https://craftquantities.com/calculators/electrical/electrical-load-calculator/)
- [Water Leak Cost Calculator](https://craftquantities.com/calculators/financial-adjacent/water-leak-cost-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/appliance-energy-cost-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/appliance-energy-cost-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `appliance-energy-cost-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/appliance-energy-cost-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/appliance-energy-cost-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.