# Amps to Watts Calculator (120 V)

> Convert a current draw in amps into watts on a standard US 120 V single-phase circuit.

Page: https://craftquantities.com/calculators/electrical/amps-to-watts-120v-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Power: 1,800 W for Current 15, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Current (A) | `amps` | 15 | 15 | range 0–200 |

- **Current (A)**: The current the appliance or circuit draws, in amps.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Power** | 1,800 W |
| Conversion factor applied | 120 W per A |

### US customary

| Result | Value |
|---|---|
| **Power** | 1,800 W |
| Conversion factor applied | 120 W per A |

## How it is worked out

P = V × I at 120 V single phase, with a power factor of 1 assumed. Assumes a resistive load. For motors and other inductive loads, multiply by the power factor to get real power.

The working the page shows, in order: Conversion factor applied; then power.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- Assumes a power factor of 1, so what it really produces is volt-amps. A motor, compressor or switch-mode supply turns less of that into work — real watts are the volt-amps multiplied by the power factor — and a single current figure gives the calculator no way to tell which kind of load you entered.
- Uses the nominal 120 V, not your measured supply. Delivered voltage moves within a tolerance band and sags further along a loaded branch circuit, so a supply sitting a few percent off 120 V shifts the answer by the same proportion.
- This is not a load calculation and is not a basis for sizing a conductor or an overcurrent device. It applies no continuous-load allowance, no demand or diversity factors, and no derating for ambient temperature or conduit fill. Cable and protection are sized from current against the applicable code tables, not from this wattage.
- 120 V single-phase only. Feeding it the current of a 240 V split-phase appliance — range, dryer, water heater — returns half the real power, and three-phase equipment follows a different relationship carrying an additional root-three term.
- Steady running current only. Motor starting surge is several times this figure and is not represented, and the result is a rate rather than a quantity of energy — getting kWh needs the running hours as well.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Ohm's law for real power on a resistive single-phase load: P = V x I
- US residential general-purpose branch circuits are nominally 120 V

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does my motor deliver less real power than this suggests?**

Because an inductive load has a power factor below 1. Volts times amps gives apparent power in VA; real power in watts is that figure multiplied by the power factor, which on a small motor might be 0.8. The two only coincide on resistive loads such as heaters and incandescent lamps.

**Can I use my breaker rating as the current?**

No. The breaker protects the conductor, and sizing a load calculation from it assumes every circuit is fully loaded all the time. Use the nameplate running current of what is actually connected.

**Is US voltage 120 V or 110 V?**

Nominally 120 V. The 110 V and 115 V figures are historic and still in casual use, but modern US distribution is specified at 120 V, and calculations should use it. Actual delivered voltage varies with distance from the transformer.

## Related calculators

- [Watts to Amps Calculator (120 V)](https://craftquantities.com/calculators/electrical/watts-to-amps-120v-calculator/)
- [Watts, Amps and kVA Calculator (Any Voltage, AC or DC)](https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/)
- [Electrical Circuit Load Calculator](https://craftquantities.com/calculators/electrical/electrical-load-calculator/)
- [Amperage to Wire Gauge Calculator](https://craftquantities.com/calculators/electrical/amperage-to-wire-gauge-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/amps-to-watts-120v-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/amps-to-watts-120v-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `amps-to-watts-120v-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/amps-to-watts-120v-calculator.json

---
Source: https://craftquantities.com/calculators/electrical/amps-to-watts-120v-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.