# Whole-house ventilation (MVHR or HRV) takeoff

> Fit whole-house ventilation from one central unit, heat recovery (MVHR; an HRV or ERV in North America) or extract only: dust sheets under the ceilings cut for valves, supports along the ducts, vapour-tight insulation on the ducts to the outside and on any duct through cold space, mastic where the joints take it, and the waste, with the airflow design, the unit, the ducting itself, the valves and terminals, the condensate, the electrics, the door undercuts and the commissioning listed and never certified.

Page: https://craftquantities.com/build/whole-house-ventilation/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor of the rooms with a valve | `floorArea` | 70 m² | 750 sq ft | m2, ft2, mm2, in2 |
| Duct from the unit to the rooms, every run added | `roomDucts` | 40 m | 130 ft | mm, cm, m, in, ft, yd |
| From the unit to each outside terminal | `outsideDuct` | 3 m | 10 ft | mm, cm, m, in, ft, yd |
| Room duct through a cold loft (attic) or void | `coldDuct` | 12 m | 39 ft | mm, cm, m, in, ft, yd |
| Room duct diameter | `roomDuctSize` | 100 mm | 4 in | mm, cm, m, in, ft, yd |
| Outside duct diameter | `outsideDuctSize` | 150 mm | 6 in | mm, cm, m, in, ft, yd |
| Duct insulation thickness | `wrapThickness` | 25 mm | 1 in | mm, cm, m, in, ft, yd |
| Joints sealed with mastic | `ductJoints` | 0 | 0 | a number |
| Loose waste, as a depth over those rooms | `wasteDepth` | 6 mm | 0.25 in | mm, cm, m, in, ft, yd |

- **Floor of the rooms with a valve**: Every room a valve goes into, supply or extract, and the landing or cupboard the unit is reached from: a ceiling cut for a valve drops its dust on the floor below. The dust sheets and the waste follow it.
- **Duct from the unit to the rooms, every run added**: Each run from the unit, or from its distribution box, to a valve, added together, with the trunk ducts between them. The supports follow it with the ducts to the outside.
- **From the unit to each outside terminal**: One duct's length between the unit and its terminal on the wall or roof. A heat recovery unit has two, the fresh air in and the stale air out, so its rows take this twice; a central extract unit has one.
- **Room duct through a cold loft (attic) or void**: The part of the room runs that crosses a loft (attic), a floor void or a garage outside the insulation, which is wrapped. 0 where every room duct stays inside the heated house, which leaves that insulation row out.
- **Room duct diameter**: The size of the ducts to the rooms, for the insulation round them and the mastic at their joints: British semi-rigid radial duct is about 75 or 90 mm (3 or 3 1/2 in) across, North American branch duct 4 to 6 in (100 to 150 mm). For a flat or oval duct, the diameter of a round one of the same girth.
- **Outside duct diameter**: The size of the ducts between the unit and its terminals, for the insulation round them; they are larger than the room ducts because they carry the whole house's air.
- **Duct insulation thickness**: The thickness of the wrap, which makes the girth it goes round larger than the duct's; the rules and the unit's maker set the thickness for a duct in a cold space or carrying cold air.
- **Joints sealed with mastic**: Where the ducts are rigid metal or flexible duct sealed with a brushed mastic, the North American practice: every place two pieces meet, at the unit's spigots, the terminals, each boot, each branch and every join between lengths. 0 where the duct system seals its own joints with clips and seals, as semi-rigid radial duct and most British plastic duct do, which leaves the mastic row out. The page opens at 0 in both markets, so a North American reader whose ducts take mastic gives the joints here to see that row.
- **Loose waste, as a depth over those rooms**: The loose volume the job makes for each square metre (square foot) of the rooms you gave: the unit's and the ducts' boxes, duct offcuts, the cores cut from ceilings and walls, and the old extract fans. 6 mm (about 1/4 in) over 70 m² (about 750 sq ft) is 0.42 m³ (about 0.55 cubic yards).

## Build-up choices

| Choice | id | Options | Opens on (metric / US customary) |
|---|---|---|---|
| The central unit | `unit` | Heat recovery (MVHR; an HRV or ERV) (`recovery`); Central extract only (MEV; central exhaust) (`extract`) | `recovery` / `recovery` |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Dust sheets under the ceilings being cut | 7 items |  | Masking and Protection Materials Calculator |
| Duct supports (hangers, straps or clips) along the runs | 20 hangers |  | HVAC Duct Hanger Support Spacing Calculator |
| Vapour-tight insulation on the two outside ducts | 4.15 m² |  | Duct Insulation Wrap Area Calculator |
| Insulation on the room ducts in cold spaces | 6.22 m² |  | Duct Insulation Wrap Area Calculator |
| Skip (dumpster) or a waste collection | 0.42 m³ |  | Skip & Dumpster Size Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Dust sheets under the ceilings being cut | 7 items |  | Masking and Protection Materials Calculator |
| Duct supports (hangers, straps or clips) along the runs | 20 hangers |  | HVAC Duct Hanger Support Spacing Calculator |
| Vapour-tight insulation on the two outside ducts | 46.1 sq ft |  | Duct Insulation Wrap Area Calculator |
| Insulation on the room ducts in cold spaces | 67.4 sq ft |  | Duct Insulation Wrap Area Calculator |
| Skip (dumpster) or a waste collection | 0.579 yd³ |  | Skip & Dumpster Size Calculator |

## Calculators it runs

- [Masking and Protection Materials Calculator](https://craftquantities.com/calculators/renovation-construction/masking-and-protection-calculator/)
- [HVAC Duct Hanger Support Spacing Calculator](https://craftquantities.com/calculators/materials-quantities/duct-hanger-spacing-calculator/)
- [Duct Insulation Wrap Area Calculator](https://craftquantities.com/calculators/materials-quantities/duct-insulation-wrap-calculator/)
- [Skip & Dumpster Size Calculator](https://craftquantities.com/calculators/auto-utility/skip-and-dumpster-size-calculator/)

## Not counted

- The design and its figures: how much air each space needs, the unit and its fan speeds, the duct sizes and the valve positions, set by Approved Document F in England or ASHRAE 62.2 in the US. It is one listed item, the designer's; the site's pages for air change and duct size answer sizes, and none is reached here.
- An airtightness test (a blower door test), which a designer may ask for before the unit is chosen or after it is in.
- Combustion air for an open-flued boiler, fire or stove. A balanced unit in a tighter home can starve one of air, which is a question for a gas or solid fuel engineer, not for this job.
- Fire dampers and fire-rated duct where a duct passes a fire-separating wall or floor: the fire-stopping round the duct is listed, and which damper, if any, is the fire strategy's.
- Fans room by room instead of this job's one unit, each with its own duct and grille: a job of its own, one fan at a time, with its own takeoff on this site. Positive input (a PIV unit), blowing air in from the loft, is another thing again.
- Heating or cooling the air in the ducts: a post-heater, a cooling coil, a ducted heat pump or an air conditioner, and a summer bypass sold as a separate module.
- Measuring the ducting by length with its bends, branches and distribution boxes, and counting the valves and the grilles or cowls where the ducts leave the house: each follows the designer's layout and the maker's range, so each is listed as work, not a row.
- Redecorating beyond making good: the plaster round each valve, the cores and any boxing are made good as listed work, and repainting whole rooms is not in this job.
- Servicing once the job is done, and filters after the first set; the unit's filter schedule is among the papers the owner is given.

## Frequently asked questions

**What does the whole-house ventilation takeoff give for a typical job?**

Opened at Floor of the rooms with a valve 70 m² · Duct from the unit to the rooms, every run added 40 m · From the unit to each outside terminal 3 m · Room duct through a cold loft (attic) or void 12 m · Room duct diameter 100 mm · Outside duct diameter 150 mm · Duct insulation thickness 25 mm · Joints sealed with mastic 0 · Loose waste, as a depth over those rooms 6 mm, it orders: Dust sheets under the ceilings being cut, 7 items; Duct supports (hangers, straps or clips) along the runs, 20 hangers; Vapour-tight insulation on the two outside ducts, 4.15 m²; Insulation on the room ducts in cold spaces, 6.22 m²; Skip (dumpster) or a waste collection, 0.42 m³. Opened at Floor of the rooms with a valve 750 sq ft · Duct from the unit to the rooms, every run added 130 ft · From the unit to each outside terminal 10 ft · Room duct through a cold loft (attic) or void 39 ft · Room duct diameter 4 in · Outside duct diameter 6 in · Duct insulation thickness 1 in · Joints sealed with mastic 0 · Loose waste, as a depth over those rooms 0.25 in: Dust sheets under the ceilings being cut, 7 items; Duct supports (hangers, straps or clips) along the runs, 20 hangers; Vapour-tight insulation on the two outside ducts, 46.1 sq ft; Insulation on the room ducts in cold spaces, 67.4 sq ft; Skip (dumpster) or a waste collection, 0.58 yd³. Every figure follows the dimensions you give it.

**Which calculators does the whole-house ventilation takeoff run?**

4 calculators, for 5 lines: Masking and Protection Materials Calculator, HVAC Duct Hanger Support Spacing Calculator, Duct Insulation Wrap Area Calculator, Skip & Dumpster Size Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the whole-house ventilation takeoff leave out?**

9 things, each named on this page: The design and its figures; An airtightness test (a blower door test), which a designer may ask for before the unit is chosen or after it is in; Combustion air for an open-flued boiler, fire or stove; Fire dampers and fire-rated duct where a duct passes a fire-separating wall or floor; Fans room by room instead of this job's one unit, each with its own duct and grille; Heating or cooling the air in the ducts; Measuring the ducting by length with its bends, branches and distribution boxes, and counting the valves and the grilles or cowls where the ducts leave the house; Redecorating beyond making good; Servicing once the job is done, and filters after the first set; the unit's filter schedule is among the papers the owner is given.

**Can I check a quote for this job against the takeoff?**

Yes. The whole-house ventilation quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/whole-house-ventilation` describes it; `https://api.craftquantities.com/v1/takeoff/whole-house-ventilation/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `whole-house-ventilation`.

---
Source: https://craftquantities.com/build/whole-house-ventilation/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.