# Wet-room tanking takeoff

> Liquid membrane, isolation layer and backer board for a room with no tray and no threshold.

Page: https://craftquantities.com/build/wet-room-tanking/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor length | `floorLength` | 2.5 m | 8 ft | mm, cm, m, in, ft, yd |
| Floor width | `floorWidth` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd |
| Tanked wall run | `wallRun` | 6 m | 19.5 ft | mm, cm, m, in, ft, yd |
| Tanked height | `wallHeight` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd |
| Internal corners in the tanked zone | `corners` | 2 | 2 | a number |
| Pipe penetrations through the membrane | `penetrations` | 3 | 3 | a number |
| Pre-formed former footprint | `formerFootprint` | 0 m² | 0 sq ft | m2, ft2, mm2, in2 |

- **Tanked wall run**: Add the widths of every wall being tanked.
- **Internal corners in the tanked zone**: Vertical wall-to-wall corners inside the tanked walls. Each takes tape for the full tanked height.
- **Pipe penetrations through the membrane**: Every supply pipe and valve body that passes through the membrane. A mixer valve is usually two and a riser one. Each takes a preformed collar, which the tanking row counts; the tape runs along the junctions only. Leave the drain out: its collar comes with the drain, which this takeoff does not include.
- **Pre-formed former footprint**: Floor covered by a pre-formed shower former that makes the fall, which is laid in place of the backer and tanked over. A 1200 × 1200 mm former is about 1.44 m² (15.5 sq ft); a 48 × 48 in one is 16 sq ft (1.49 m²). It comes off the backer only: the membrane, isolation and tape still cover the whole floor. Enter 0 where the fall is built into the deck or a screed.

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Wet Room Tanking and Waterproof Membrane | 34 litres |  | Wet Room Tanking and Waterproof Membrane Calculator |
| Floor Crack Isolation Membrane Coverage | 1 rolls |  | Floor Crack Isolation Membrane Coverage Calculator |
| Tile Backer Board | 21 boards |  | Tile Backer Board Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Wet Room Tanking and Waterproof Membrane | 9 gal |  | Wet Room Tanking and Waterproof Membrane Calculator |
| Floor Crack Isolation Membrane Coverage | 1 rolls |  | Floor Crack Isolation Membrane Coverage Calculator |
| Tile Backer Board | 20 boards |  | Tile Backer Board Calculator |

## Calculators it runs

- [Wet Room Tanking and Waterproof Membrane Calculator](https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/)
- [Floor Crack Isolation Membrane Coverage Calculator](https://craftquantities.com/calculators/materials-quantities/crack-isolation-membrane-calculator/)
- [Tile Backer Board Calculator](https://craftquantities.com/calculators/renovation-construction/backer-board-calculator/)

## Not counted

- The drain, its collar and the connection to the waste.
- Preformed corner pieces, where the system uses them at the corners in place of tape.
- The floor's fall and whatever forms it: a former, a graded deck or a screed.
- Tiling, adhesive and grout over the membrane.
- Primer, which absorbent substrates need and cement backer board often does not; apply the maker's rate to the tanked area in the tanking row's breakdown.
- Whether the structure below tolerates a wet room at all — a timber floor with no access beneath is a different risk from a slab.

## Frequently asked questions

**What does the wet-room tanking takeoff give for a typical job?**

Opened at Floor length 2.5 m · Floor width 2 m · Tanked wall run 6 m · Tanked height 2 m · Internal corners in the tanked zone 2 · Pipe penetrations through the membrane 3 · Pre-formed former footprint 0 m², it orders: Wet Room Tanking and Waterproof Membrane, 34 litres; Floor Crack Isolation Membrane Coverage, 1 roll; Tile Backer Board, 21 boards. Opened at Floor length 8 ft · Floor width 6.5 ft · Tanked wall run 19.5 ft · Tanked height 6.5 ft · Internal corners in the tanked zone 2 · Pipe penetrations through the membrane 3 · Pre-formed former footprint 0 sq ft: Wet Room Tanking and Waterproof Membrane, 9 gal; Floor Crack Isolation Membrane Coverage, 1 roll; Tile Backer Board, 20 boards. Every figure follows the dimensions you give it.

**Which calculators does the wet-room tanking takeoff run?**

3 calculators, one to a line: Wet Room Tanking and Waterproof Membrane Calculator, Floor Crack Isolation Membrane Coverage Calculator, Tile Backer Board Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the wet-room tanking takeoff leave out?**

6 things, each named on this page: The drain, its collar and the connection to the waste; Preformed corner pieces, where the system uses them at the corners in place of tape; The floor's fall and whatever forms it; Tiling, adhesive and grout over the membrane; Primer, which absorbent substrates need and cement backer board often does not; apply the maker's rate to the tanked area in the tanking row's breakdown; Whether the structure below tolerates a wet room at all.

**Can I check a quote for this job against the takeoff?**

Yes. The wet-room tanking quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program