# Wet underfloor heating in an existing floor takeoff

> Lay wet underfloor heating (radiant floor heating) into a floor that is already there: dust sheets on the route and tape at the doorways, the insulation or grooved panels, the pipe loops and their leaders at the designer's centres, a levelling compound, a screed or relaid boards over them, the finish, transition strips at the doorways and the skip, with the manifold, the edge strip, the pressure test before anything covers the pipe, the warm-up and the door trimming listed, and the height it adds flagged.

Page: https://craftquantities.com/build/underfloor-heating-retrofit/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor to be heated | `heatedArea` | 20 m² | 220 sq ft | m2, ft2, mm2, in2 |
| Circuits (loops) off the manifold | `circuits` | 2 | 2 | a number |
| Manifold to the heated floor, one way | `manifoldRoute` | 3 m | 10 ft | mm, cm, m, in, ft, yd |
| Doorways where the new floor meets another | `doorways` | 2 | 2 | a number |
| Floor sheeted along the route through the house | `routeArea` | 8 m² | 86 sq ft | m2, ft2, mm2, in2 |
| Loose waste, as a depth over the heated floor | `wasteDepth` | 15 mm | 0.59 in | mm, cm, m, in, ft, yd |

- **Floor to be heated**: The area the loops go under, room by room added together, less any fixed units or fittings nothing is laid beneath. The insulation, the pipe, what covers it, the finish and the waste all follow it.
- **Circuits (loops) off the manifold**: How many loops the designer's layout puts under the floor. Each has its own flow and return between the room and the manifold, which is where the leaders come from; enter 0 for the route where the manifold is in the room.
- **Manifold to the heated floor, one way**: How far the pipe runs from the manifold to where the loops begin, one way. Every loop has a flow and a return over it, so the pipe row adds circuits × 2 × this. 0 where the manifold is in the heated room.
- **Doorways where the new floor meets another**: Each doorway where the raised floor meets the next room's floor: each takes a transition strip, and its door is trimmed and its opening taped against dust while the old floor comes up. 0 leaves the strip row out.
- **Floor sheeted along the route through the house**: The hall, landing or next room the old floor goes out through and the new materials come in by. The heated floor itself is taken up, so it is not sheeted.
- **Loose waste, as a depth over the heated floor**: The loose volume the job makes for each square metre (square foot) heated: the old finish and its underlay or adhesive, the skirting, the radiators taken off and the packaging. 15 mm over 20 m² is 0.3 m³; 0.59 in over 220 sq ft is about 0.4 cubic yards. Where an old screed is broken out, it is several times that.

## Build-up choices

| Choice | id | Options | Opens on (metric / US customary) |
|---|---|---|---|
| How the pipe goes into the floor | `buildUp` | Grooved low-profile panels over the old floor, levelling compound over (`panels`); Insulation and a screed, the old screed dug out (`screed`); Between the joists of a timber floor, boards relaid (`joists`) | `panels` / `panels` |
| Pipe centres (the designer's) | `centres` | About 150 mm (6 in) apart (`6in`); About 230 mm (9 in) apart (`9in`); About 300 mm (12 in) apart (`12in`) | `6in` / `6in` |
| Floor finish | `finish` | Tiles (`tile`); Click boards on an underlay (`boards`); Carpet, listed as work (`carpet`) | `tile` / `tile` |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Dust sheets on the route, and tape round the doorways | 2 items |  | Masking and Protection Materials Calculator |
| Grooved panels (low-profile boards) | 8 sheets (2400x1200 mm) |  | Foam Board Insulation Calculator |
| Pipe loops and leaders (PEX) | 156 m of pex |  | Radiant Floor PEX Tubing Calculator |
| Levelling compound or latex screed (self-leveling underlayment) | 120 L |  | Self-Leveling Underlayment (SLU) Volume Calculator |
| Floor tiles | 62 tiles |  | Floor & Wall Tile Calculator |
| Tile adhesive, flexible | 5 bags |  | Thinset & Tile Adhesive Calculator |
| Transition strips (door bars, T-moldings) at the doorways | 1.89 m |  | Floor Transition Strip Calculator |
| Skip (dumpster) for what is taken up | 0.3 m³ |  | Skip & Dumpster Size Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Dust sheets on the route, and tape round the doorways | 2 items |  | Masking and Protection Materials Calculator |
| Grooved panels (low-profile boards) | 8 sheets (4x8 ft) |  | Foam Board Insulation Calculator |
| Pipe loops and leaders (PEX) | 524 linear ft of PEX |  | Radiant Floor PEX Tubing Calculator |
| Levelling compound or latex screed (self-leveling underlayment) | 34.3 gal |  | Self-Leveling Underlayment (SLU) Volume Calculator |
| Floor tiles | 61 tiles |  | Floor & Wall Tile Calculator |
| Tile adhesive, flexible | 5 bags |  | Thinset & Tile Adhesive Calculator |
| Transition strips (door bars, T-moldings) at the doorways | 6.3 ft |  | Floor Transition Strip Calculator |
| Skip (dumpster) for what is taken up | 0.401 yd³ |  | Skip & Dumpster Size Calculator |

## Calculators it runs

- [Masking and Protection Materials Calculator](https://craftquantities.com/calculators/renovation-construction/masking-and-protection-calculator/)
- [Foam Board Insulation Calculator](https://craftquantities.com/calculators/insulation-efficiency/foam-board-insulation-calculator/)
- [Radiant Floor PEX Tubing Calculator](https://craftquantities.com/calculators/plumbing-hvac/radiant-floor-pex-calculator/)
- [Self-Leveling Underlayment (SLU) Volume Calculator](https://craftquantities.com/calculators/materials-quantities/self-leveling-underlayment-calculator/)
- [Floor & Wall Tile Calculator](https://craftquantities.com/calculators/renovation-construction/floor-tile-calculator/)
- [Thinset & Tile Adhesive Calculator](https://craftquantities.com/calculators/renovation-construction/thinset-mortar-calculator/)
- [Floor Transition Strip Calculator](https://craftquantities.com/calculators/materials-quantities/floor-transition-strip-calculator/)
- [Skip & Dumpster Size Calculator](https://craftquantities.com/calculators/auto-utility/skip-and-dumpster-size-calculator/)

## Not counted

- The heat source itself, a boiler or a heat pump, and whether it can run as cool as the loops ask: that is its own job, and only resetting it is listed.
- The loop layout, the heat each room's floor gives out and the pipe centres, which the designer sets. The centres here are one of the three the pipe page offers, for the reader to change to the designer's.
- Whether a suspended timber floor carries a screed's weight, which is flagged: strengthening the floor, or changing to a lighter build-up, is for the designer or an engineer.
- Raising door frames, the stair, kitchen plinths or fitted furniture to the new floor level. Trimming the doors is listed; the shorter bottom riser the raised floor leaves at the foot of a stair is flagged, and resetting the stair is another job.
- Whether the chosen tiles, boards or carpet suit being heated, beyond naming the question: how warm each may run and how much each holds the heat back come from its maker.
- An electric mat or cable system under the floor, which is heated another way; the heated bathroom floor takeoff counts one.
- Removing asbestos the survey finds in the old floor, which is specialist or licensed work with its own programme.
- Damp found in the floor once it is opened up, and whatever damp proof layer or damp-proof course it then needs.
- Redecorating the walls marked where the old emitters hung; making good their brackets and pipe holes is listed.

## Frequently asked questions

**What does the underfloor heating retrofit takeoff give for a typical job?**

Opened at Floor to be heated 20 m² · Circuits (loops) off the manifold 2 · Manifold to the heated floor, one way 3 m · Doorways where the new floor meets another 2 · Floor sheeted along the route through the house 8 m² · Loose waste, as a depth over the heated floor 15 mm, it orders: Dust sheets on the route, and tape round the doorways, 2 items; Grooved panels (low-profile boards), 8 sheets (2400x1200 mm); Pipe loops and leaders (PEX), 156 m of pex; Levelling compound or latex screed (self-leveling underlayment), 120 L; Floor tiles, 62 tiles; Tile adhesive, flexible, 5 bags; Transition strips (door bars, T-moldings) at the doorways, 1.89 m; Skip (dumpster) for what is taken up, 0.3 m³. Opened at Floor to be heated 220 sq ft · Circuits (loops) off the manifold 2 · Manifold to the heated floor, one way 10 ft · Doorways where the new floor meets another 2 · Floor sheeted along the route through the house 86 sq ft · Loose waste, as a depth over the heated floor 0.59 in: Dust sheets on the route, and tape round the doorways, 2 items; Grooved panels (low-profile boards), 8 sheets (4x8 ft); Pipe loops and leaders (PEX), 524 linear ft of PEX; Levelling compound or latex screed (self-leveling underlayment), 34.3 gal; Floor tiles, 61 tiles; Tile adhesive, flexible, 5 bags; Transition strips (door bars, T-moldings) at the doorways, 6.3 ft; Skip (dumpster) for what is taken up, 0.4 yd³. Every figure follows the dimensions you give it.

**Which calculators does the underfloor heating retrofit takeoff run?**

8 calculators, one to a line: Masking and Protection Materials Calculator, Foam Board Insulation Calculator, Radiant Floor PEX Tubing Calculator, Self-Leveling Underlayment (SLU) Volume Calculator, Floor & Wall Tile Calculator, Thinset & Tile Adhesive Calculator, Floor Transition Strip Calculator, Skip & Dumpster Size Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the underfloor heating retrofit takeoff leave out?**

9 things, each named on this page: The heat source itself, a boiler or a heat pump, and whether it can run as cool as the loops ask; The loop layout, the heat each room's floor gives out and the pipe centres, which the designer sets; Whether a suspended timber floor carries a screed's weight, which is flagged; Raising door frames, the stair, kitchen plinths or fitted furniture to the new floor level; Whether the chosen tiles, boards or carpet suit being heated, beyond naming the question; An electric mat or cable system under the floor, which is heated another way; the heated bathroom floor takeoff counts one; Removing asbestos the survey finds in the old floor, which is specialist or licensed work with its own programme; Damp found in the floor once it is opened up, and whatever damp proof layer or damp-proof course it then needs; Redecorating the walls marked where the old emitters hung; making good their brackets and pipe holes is listed.

**Can I check a quote for this job against the takeoff?**

Yes. The underfloor heating retrofit quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/underfloor-heating-retrofit` describes it; `https://api.craftquantities.com/v1/takeoff/underfloor-heating-retrofit/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `underfloor-heating-retrofit`.

---
Source: https://craftquantities.com/build/underfloor-heating-retrofit/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.