# New-build service connections (water and sewer) takeoff

> The trenches, bedding, backfill and pipe for a new house's water service and sewer lateral, from each run's length and depth, with the sewer's fall.

Page: https://craftquantities.com/build/service-connections/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Water service run, main to house | `waterLength` | 15 m | 49 ft | mm, cm, m, in, ft, yd |
| Water trench depth | `waterDepth` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd |
| Sewer lateral run, house to connection | `sewerLength` | 15 m | 49 ft | mm, cm, m, in, ft, yd |
| Sewer trench depth, average | `sewerDepth` | 1.2 m | 4 ft | mm, cm, m, in, ft, yd |
| Trench width | `trenchWidth` | 450 mm | 18 in | mm, cm, m, in, ft, yd |
| Bedding under the pipe | `beddingBelow` | 100 mm | 4 in | mm, cm, m, in, ft, yd |
| Surround over the pipe | `surroundAbove` | 100 mm | 4 in | mm, cm, m, in, ft, yd |
| Water pipe outside diameter | `waterPipeDiameter` | 32 mm | 1.25 in | mm, cm, m, in, ft, yd |
| Sewer pipe outside diameter | `sewerPipeDiameter` | 110 mm | 4.25 in | mm, cm, m, in, ft, yd |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Water service trench: dig, bedding and backfill | 5.19 m³ (loose) |  | Trench Excavation & Backfill Volume Calculator |
| Sewer lateral trench: dig, bedding and backfill | 6.91 m³ (loose) |  | Trench Excavation & Backfill Volume Calculator |
| Water service pipe | 16.5 m |  | Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route) |
| Sewer lateral pipe | 16.8 m |  | Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route) |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Water service trench: dig, bedding and backfill | 6.98 yd³ |  | Trench Excavation & Backfill Volume Calculator |
| Sewer lateral trench: dig, bedding and backfill | 9.33 yd³ |  | Trench Excavation & Backfill Volume Calculator |
| Water service pipe | 54 ft |  | Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route) |
| Sewer lateral pipe | 55 ft |  | Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route) |

## Calculators it runs

- [Trench Excavation & Backfill Volume Calculator](https://craftquantities.com/calculators/materials-quantities/trench-excavation-backfill-calculator/)
- [Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route)](https://craftquantities.com/calculators/materials-quantities/service-run-calculator/)

## Not counted

- The sizes: the water pipe's diameter, the sewer's, the depth of cover and the falls are the water supplier's, the sewer authority's and the code's, and this page takes them as entered.
- The separation the two services must keep from each other, and from other buried services, which the local rules set.
- The connections themselves: the tapping on the main, the meter and its box, the sewer junction or saddle, inspection chambers and cleanouts, each a fitting the supplier or the authority specifies.
- Work in the road or on land that is not the plot, which needs the highway authority's or the owner's consent.
- The surface over the trenches once they are backfilled: turf, paving or a drive.
- The sewer's least fall, which the drain slope page gives for the pipe's size over this length; the depths at each end must allow it.

## Frequently asked questions

**What does the water and sewer connection takeoff give for a typical job?**

Opened at Water service run, main to house 15 m · Water trench depth 0.9 m · Sewer lateral run, house to connection 15 m · Sewer trench depth, average 1.2 m · Trench width 450 mm · Bedding under the pipe 100 mm · Surround over the pipe 100 mm · Water pipe outside diameter 32 mm · Sewer pipe outside diameter 110 mm, it orders: Water service trench: dig, bedding and backfill, 5.19 m³ (loose); Sewer lateral trench: dig, bedding and backfill, 6.91 m³ (loose); Water service pipe, 16.5 m; Sewer lateral pipe, 16.8 m. Opened at Water service run, main to house 49 ft · Water trench depth 3 ft · Sewer lateral run, house to connection 49 ft · Sewer trench depth, average 4 ft · Trench width 18 in · Bedding under the pipe 4 in · Surround over the pipe 4 in · Water pipe outside diameter 1.25 in · Sewer pipe outside diameter 4.25 in: Water service trench: dig, bedding and backfill, 6.98 yd³; Sewer lateral trench: dig, bedding and backfill, 9.33 yd³; Water service pipe, 54 ft; Sewer lateral pipe, 55 ft. Every figure follows the dimensions you give it.

**Which calculators does the water and sewer connection takeoff run?**

2 calculators, for 4 lines: Trench Excavation & Backfill Volume Calculator, Pipe, Conduit and Cable Run Calculator (Length, Fittings and Supports from a Measured Route). Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the water and sewer connection takeoff leave out?**

6 things, each named on this page: The sizes; The separation the two services must keep from each other, and from other buried services, which the local rules set; The connections themselves; Work in the road or on land that is not the plot, which needs the highway authority's or the owner's consent; The surface over the trenches once they are backfilled; The sewer's least fall, which the drain slope page gives for the pipe's size over this length; the depths at each end must allow it.

**Can I check a quote for this job against the takeoff?**

Yes. The water and sewer connection quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/service-connections` describes it; `https://api.craftquantities.com/v1/takeoff/service-connections/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `service-connections`.

---
Source: https://craftquantities.com/build/service-connections/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.