# Recessed lighting layout takeoff

> Whether the fittings you plan give the room enough light, how many a target level needs and at what spacing, and whether the circuit will carry them.

Page: https://craftquantities.com/build/recessed-lighting/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Room length | `length` | 5 m | 16.5 ft | mm, cm, m, in, ft, yd |
| Room width | `width` | 4 m | 13 ft | mm, cm, m, in, ft, yd |
| Fittings | `fixtures` | 8 | 8 | a number |
| Lumens per fitting (the fitting's rated output) | `lumensEach` | 800 | 800 | a number |
| Ceiling height | `ceilingHeight` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd |
| Target light level | `targetLux` | 300 lx | 28 fc | lux, fc |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Lighting Illuminance (Lux) | 320 lux |  | Lighting Illuminance (Lux) Calculator |
| Lumen Method Lighting (Room Index, Luminaire Count and Spacing) | 16 luminaires |  | Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing) |
| Lighting Circuit Connected Load | 480 W |  | Lighting Circuit Connected Load Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Lighting Illuminance (Lux) | 321 lux |  | Lighting Illuminance (Lux) Calculator |
| Lumen Method Lighting (Room Index, Luminaire Count and Spacing) | 16 luminaires |  | Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing) |
| Lighting Circuit Connected Load | 480 W |  | Lighting Circuit Connected Load Calculator |

## Calculators it runs

- [Lighting Illuminance (Lux) Calculator](https://craftquantities.com/calculators/materials-quantities/lighting-illuminance-calculator/)
- [Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)](https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/)
- [Lighting Circuit Connected Load Calculator](https://craftquantities.com/calculators/materials-quantities/lighting-circuit-load-calculator/)

## Not counted

- The fitting's photometric data. The count and the grid rest on its spacing-to-height ratio and utilisation factor, which this page leaves at the calculator's placeholders; set them from the data sheet on the line in your project.
- Fire rating, acoustic rating and the covers a rated ceiling needs at every penetration.
- Dimming, driver compatibility and the flicker a mismatched pair produces.
- Where the light actually falls, which an average illuminance cannot describe.
- Cutting, patching and making good the ceiling.

## Frequently asked questions

**What does the recessed lighting takeoff give for a typical job?**

Opened at Room length 5 m · Room width 4 m · Fittings 8 · Lumens per fitting (the fitting's rated output) 800 · Ceiling height 2.4 m · Target light level 300 lx, it orders: Lighting Illuminance (Lux), 320 lux; Lumen Method Lighting (Room Index, Luminaire Count and Spacing), 16 luminaires; Lighting Circuit Connected Load, 480 W. Opened at Room length 16.5 ft · Room width 13 ft · Fittings 8 · Lumens per fitting (the fitting's rated output) 800 · Ceiling height 8 ft · Target light level 28 fc: Lighting Illuminance (Lux), 321 lux; Lumen Method Lighting (Room Index, Luminaire Count and Spacing), 16 luminaires; Lighting Circuit Connected Load, 480 W. Every figure follows the dimensions you give it.

**Which calculators does the recessed lighting takeoff run?**

3 calculators, one to a line: Lighting Illuminance (Lux) Calculator, Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing), Lighting Circuit Connected Load Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the recessed lighting takeoff leave out?**

5 things, each named on this page: The fitting's photometric data; Fire rating, acoustic rating and the covers a rated ceiling needs at every penetration; Dimming, driver compatibility and the flicker a mismatched pair produces; Where the light actually falls, which an average illuminance cannot describe; Cutting, patching and making good the ceiling.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/recessed-lighting` describes it; `https://api.craftquantities.com/v1/takeoff/recessed-lighting/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `recessed-lighting`.

---
Source: https://craftquantities.com/build/recessed-lighting/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.
