# Mini-split installation takeoff

> Capacity for the room, the plan area the outdoor unit and a margin round it take up, and the fall its condensate needs.

Page: https://craftquantities.com/build/mini-split-install/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Room floor area | `floorArea` | 40 m² | 430 sq ft | m2, ft2, mm2, in2 |
| Outdoor unit width | `unitWidth` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd |
| Outdoor unit depth | `unitDepth` | 350 mm | 14 in | mm, cm, m, in, ft, yd |
| Condensate run | `drainRun` | 5 m | 16.5 ft | mm, cm, m, in, ft, yd |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Air Conditioner Size | 8,611 BTU/h |  | Air Conditioner Size Calculator |
| HVAC Equipment Pad/Curb Footprint | 0.78 m² |  | HVAC Equipment Pad/Curb Footprint Calculator |
| HVAC Condensate Drain Pipe Slope | 52.1 mm |  | HVAC Condensate Drain Pipe Slope Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Air Conditioner Size | 8,600 BTU/h |  | Air Conditioner Size Calculator |
| HVAC Equipment Pad/Curb Footprint | 8.67 sq ft |  | HVAC Equipment Pad/Curb Footprint Calculator |
| HVAC Condensate Drain Pipe Slope | 2.06 in |  | HVAC Condensate Drain Pipe Slope Calculator |

## Calculators it runs

- [Air Conditioner Size Calculator](https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/)
- [HVAC Equipment Pad/Curb Footprint Calculator](https://craftquantities.com/calculators/materials-quantities/hvac-equipment-pad-footprint-calculator/)
- [HVAC Condensate Drain Pipe Slope Calculator](https://craftquantities.com/calculators/materials-quantities/hvac-condensate-drain-slope-calculator/)

## Not counted

- A real load calculation. Room-by-room heat gain and loss is what a selection should rest on.
- The line set, its length limit, the additional refrigerant charge a long run needs, and the electrical supply.
- Wall penetration, bracket, trunking and the seal around the core.
- Noise at the boundary, which is what planning conditions and neighbours are concerned with.
- Anything requiring refrigerant handling, which is licensed work nearly everywhere.
- The manufacturer's airflow, discharge and service clearances, and the base's size, thickness and what goes under it.

## Frequently asked questions

**What does the mini-split installation takeoff give for a typical job?**

Opened at Room floor area 40 m² · Outdoor unit width 0.9 m · Outdoor unit depth 350 mm · Condensate run 5 m, it orders: Air Conditioner Size, 8,611 BTU/h; HVAC Equipment Pad/Curb Footprint, 0.78 m²; HVAC Condensate Drain Pipe Slope, 52.1 mm. Opened at Room floor area 430 sq ft · Outdoor unit width 3 ft · Outdoor unit depth 14 in · Condensate run 16.5 ft: Air Conditioner Size, 8,600 BTU/h; HVAC Equipment Pad/Curb Footprint, 8.67 sq ft; HVAC Condensate Drain Pipe Slope, 2.06 in. Every figure follows the dimensions you give it.

**Which calculators does the mini-split installation takeoff run?**

3 calculators, one to a line: Air Conditioner Size Calculator, HVAC Equipment Pad/Curb Footprint Calculator, HVAC Condensate Drain Pipe Slope Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the mini-split installation takeoff leave out?**

6 things, each named on this page: A real load calculation; The line set, its length limit, the additional refrigerant charge a long run needs, and the electrical supply; Wall penetration, bracket, trunking and the seal around the core; Noise at the boundary, which is what planning conditions and neighbours are concerned with; Anything requiring refrigerant handling, which is licensed work nearly everywhere; The manufacturer's airflow, discharge and service clearances, and the base's size, thickness and what goes under it.

**Can I check a quote for this job against the takeoff?**

Yes. The mini-split installation quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/mini-split-install` describes it; `https://api.craftquantities.com/v1/takeoff/mini-split-install/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `mini-split-install`.

---
Source: https://craftquantities.com/build/mini-split-install/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.