# Irrigation zone takeoff

> Head count by spacing, head count by available flow, and the trench to get water there.

Page: https://craftquantities.com/build/irrigation-zone/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Zone length | `zoneLength` | 12 m | 39 ft | mm, cm, m, in, ft, yd |
| Zone width | `zoneWidth` | 8 m | 26 ft | mm, cm, m, in, ft, yd |
| Trench run | `trenchRun` | 30 m | 98 ft | mm, cm, m, in, ft, yd |
| Trench depth | `trenchDepth` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd |
| Trench width | `trenchWidth` | 200 mm | 7.75 in | mm, cm, m, in, ft, yd |
| Sand bed under the pipe | `sandBelow` | 50 mm | 2 in | mm, cm, m, in, ft, yd |
| Sand cover over the pipe | `sandCover` | 50 mm | 2 in | mm, cm, m, in, ft, yd |

- **Sand bed under the pipe**: The sand the pipe is laid on, from the trench bottom to the underside of the pipe. Set this and the cover to 0 where the dug soil is free of stones and goes straight back round the pipe.
- **Sand cover over the pipe**: The sand over the top of the pipe before the dug soil goes back.

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Sprinkler Head Spacing and Count | 12 heads |  | Sprinkler Head Spacing and Count Calculator |
| Irrigation Zone | 5 heads per zone |  | Irrigation Zone Calculator |
| Trench Excavation & Backfill Volume | 1.21 m³ (loose) |  | Trench Excavation & Backfill Volume Calculator |
| Sand bed and cover round the pipe | 0.846 m³ (loose) |  | Trench Excavation & Backfill Volume Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Sprinkler Head Spacing and Count | 12 heads |  | Sprinkler Head Spacing and Count Calculator |
| Irrigation Zone | 5 heads per zone |  | Irrigation Zone Calculator |
| Trench Excavation & Backfill Volume | 1.52 yd³ |  | Trench Excavation & Backfill Volume Calculator |
| Sand bed and cover round the pipe | 1.1 yd³ |  | Trench Excavation & Backfill Volume Calculator |

## Calculators it runs

- [Sprinkler Head Spacing and Count Calculator](https://craftquantities.com/calculators/landscaping-outdoor/sprinkler-head-spacing-calculator/)
- [Irrigation Zone Calculator](https://craftquantities.com/calculators/landscaping-outdoor/irrigation-zone-calculator/)
- [Trench Excavation & Backfill Volume Calculator](https://craftquantities.com/calculators/materials-quantities/trench-excavation-backfill-calculator/)

## Not counted

- The controller, valves, backflow prevention and the point of connection.
- Pipe sizing, which follows flow and run length rather than the zone's area.
- Pressure loss along the run, and whether the last head still performs.
- Winterisation, which in a freezing climate decides how the whole system is laid out.
- Drip irrigation for beds, which is a different system with a different layout rule.

## Frequently asked questions

**What does the irrigation takeoff give for a typical job?**

Opened at Zone length 12 m · Zone width 8 m · Trench run 30 m · Trench depth 300 mm · Trench width 200 mm · Sand bed under the pipe 50 mm · Sand cover over the pipe 50 mm, it orders: Sprinkler Head Spacing and Count, 12 heads; Irrigation Zone, 5 heads per zone; Trench Excavation & Backfill Volume, 1.21 m³ (loose); Sand bed and cover round the pipe, 0.85 m³ (loose). Opened at Zone length 39 ft · Zone width 26 ft · Trench run 98 ft · Trench depth 11.8 in · Trench width 7.75 in · Sand bed under the pipe 2 in · Sand cover over the pipe 2 in: Sprinkler Head Spacing and Count, 12 heads; Irrigation Zone, 5 heads per zone; Trench Excavation & Backfill Volume, 1.52 yd³; Sand bed and cover round the pipe, 1.1 yd³. Every figure follows the dimensions you give it.

**Which calculators does the irrigation takeoff run?**

3 calculators, for 4 lines: Sprinkler Head Spacing and Count Calculator, Irrigation Zone Calculator, Trench Excavation & Backfill Volume Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the irrigation takeoff leave out?**

5 things, each named on this page: The controller, valves, backflow prevention and the point of connection; Pipe sizing, which follows flow and run length rather than the zone's area; Pressure loss along the run, and whether the last head still performs; Winterisation, which in a freezing climate decides how the whole system is laid out; Drip irrigation for beds, which is a different system with a different layout rule.

**Can I check a quote for this job against the takeoff?**

Yes. The irrigation quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/irrigation-zone` describes it; `https://api.craftquantities.com/v1/takeoff/irrigation-zone/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `irrigation-zone`.

---
Source: https://craftquantities.com/build/irrigation-zone/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.