# Damp remediation and replastering takeoff

> Carry out the remedy a damp specification names on the walls it names: dust sheets and a taped doorway, the plaster hacked off a band to the height the specification sets, a tanking slurry where that is the remedy, the band skimmed over its backing coat, the skirting (baseboard) refitted along it, the room repainted wall to wall once the wall has dried, and the skip, with the survey, an injected damp-proof course (damp course) or a membrane, the backing coat, the radiator and the sockets listed, and nothing prescribed or promised.

Page: https://craftquantities.com/build/damp-remediation/ (whole-job takeoff). This is the page's Markdown copy; the HTML page is the canonical version.

## Measurements

Each length, area or volume is entered with its unit; one left out opens at the figure shown.

| Measurement | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Room length | `roomLength` | 4.5 m | 15 ft | mm, cm, m, in, ft, yd |
| Room width | `roomWidth` | 3.5 m | 11.5 ft | mm, cm, m, in, ft, yd |
| Wall height, floor to ceiling | `wallHeight` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd |
| Length of the walls treated | `treatedLength` | 8 m | 26 ft | mm, cm, m, in, ft, yd |
| Height of the strip-out and replastering, as the specification sets it | `treatedHeight` | 1 m | 3.5 ft | mm, cm, m, in, ft, yd |
| Doors | `doors` | 1 | 1 | a number |
| Windows | `windows` | 1 | 1 | a number |
| Loose waste, as a depth over the band | `wasteDepth` | 50 mm | 2 in | mm, cm, m, in, ft, yd |

- **Room length**: Wall to wall inside the room, the longer way. With the width and the height it gives the walls the paint row decorates and the floor the dust sheets cover.
- **Room width**: Wall to wall inside the room, the shorter way.
- **Wall height, floor to ceiling**: The room's own height, which the paint row decorates to on every wall. The height of the treatment is a separate figure below, the specification's.
- **Length of the walls treated**: Along the foot of every wall the specification names, added together, with the doorways in them left out. The skirting runs along it, and with the height below it gives the band the plaster comes off and goes back on.
- **Height of the strip-out and replastering, as the specification sets it**: The specification's figure, never this page's: usually a set height, or a margin above the highest salts or damp the survey found, confirmed once the plaster is off. The hacking off, the slurry, the membrane, the backing coat and the skim all cover the treated length times this height. What the page opens on is an example, not advice.
- **Doors**: Each door into the room: its doorway is taped round to hold a dust sheet across it, and it is taken off the paint at the paint page's own 1.95 m² (21 sq ft).
- **Windows**: Each window in the room's walls, taken off the paint at the paint page's own 1.4 m² (15 sq ft).
- **Loose waste, as a depth over the band**: The loose volume the strip-out makes for each square metre (square foot) of the band: the plaster and any render hacked back to the masonry, which bulks up as it breaks, and the old skirting. 50 mm (2 in) over an 8 m² (86 sq ft) band is 0.4 m³ (about half a cubic yard).

## Build-up choices

| Choice | id | Options | Opens on (metric / US customary) |
|---|---|---|---|
| The remedy your specification names | `remedy` | An injected damp-proof course (DPC, a damp course), the band replastered (`injected`); A tanking slurry or coating on the treated walls (`slurry`); A cavity drain membrane on the treated walls, plastered or dry-lined (`membrane`) | `injected` / `injected` |

## Quantities on the opening figures

Worked as the takeoff page works them, each row by its own calculator.

### Metric

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Masking and protection materials | 3 items |  | Masking and Protection Materials Calculator |
| Skim finish coat (plaster) | 23 kg |  | Skim Coat Plaster Calculator |
| Skirting (baseboard) | 8.8 m |  | Baseboard & Trim Calculator |
| Painting and decorating (decoration): emulsion to decorate the room, after a mist coat | 7.01 L |  | Paint Calculator |
| Skip (dumpster) | 0.4 m³ |  | Skip & Dumpster Size Calculator |

### US customary

| Item | Quantity | Order | Calculator |
|---|---|---|---|
| Masking and protection materials | 3 items |  | Masking and Protection Materials Calculator |
| Skim finish coat (plaster) | 53.6 lb |  | Skim Coat Plaster Calculator |
| Skirting (baseboard) | 28.6 linear ft |  | Baseboard & Trim Calculator |
| Painting and decorating (decoration): emulsion to decorate the room, after a mist coat | 1.94 gal |  | Paint Calculator |
| Skip (dumpster) | 0.562 yd³ |  | Skip & Dumpster Size Calculator |

## Calculators it runs

- [Masking and Protection Materials Calculator](https://craftquantities.com/calculators/renovation-construction/masking-and-protection-calculator/)
- [Skim Coat Plaster Calculator](https://craftquantities.com/calculators/materials-quantities/skim-coat-plaster-calculator/)
- [Baseboard & Trim Calculator](https://craftquantities.com/calculators/renovation-construction/baseboard-trim-calculator/)
- [Paint Calculator](https://craftquantities.com/calculators/renovation-construction/paint-calculator/)
- [Skip & Dumpster Size Calculator](https://craftquantities.com/calculators/auto-utility/skip-and-dumpster-size-calculator/)

## Not counted

- Diagnosing the cause and choosing what answers it: the surveyor's, listed as its own item.
- Ground and path levels, gutters, downpipes and render that bridge the DPC, and their repair.
- Leaking pipes, and condensation and its causes in the room's air.
- Decay in joists, lintels, floors or timber grounds (flagged).
- A drained channel and sump at the foot of the floor.
- Moving a socket to a new place.
- Any promise that the wall stays dry.
- The party structure notice to a neighbour, and any award or agreement under the 1996 Act, which are the owner's to serve and settle.
- Dehumidifiers and temporary heaters beyond the job's own.

## Frequently asked questions

**What does the damp proofing and replastering takeoff give for a typical job?**

Opened at Room length 4.5 m · Room width 3.5 m · Wall height, floor to ceiling 2.4 m · Length of the walls treated 8 m · Height of the strip-out and replastering, as the specification sets it 1 m · Doors 1 · Windows 1 · Loose waste, as a depth over the band 50 mm, it orders: Masking and protection materials, 3 items; Skim finish coat (plaster), 23 kg; Skirting (baseboard), 8.8 m; Painting and decorating (decoration): emulsion to decorate the room, after a mist coat, 7.01 L; Skip (dumpster), 0.4 m³. Opened at Room length 15 ft · Room width 11.5 ft · Wall height, floor to ceiling 8 ft · Length of the walls treated 26 ft · Height of the strip-out and replastering, as the specification sets it 3.5 ft · Doors 1 · Windows 1 · Loose waste, as a depth over the band 2 in: Masking and protection materials, 3 items; Skim finish coat (plaster), 53.6 lb; Skirting (baseboard), 28.6 linear ft; Painting and decorating (decoration): emulsion to decorate the room, after a mist coat, 1.94 gal; Skip (dumpster), 0.56 yd³. Every figure follows the dimensions you give it.

**Which calculators does the damp proofing and replastering takeoff run?**

5 calculators, one to a line: Masking and Protection Materials Calculator, Skim Coat Plaster Calculator, Baseboard & Trim Calculator, Paint Calculator, Skip & Dumpster Size Calculator. Each has a page of its own with its formula and its sources; the takeoff runs them all on one set of dimensions.

**What does the damp proofing and replastering takeoff leave out?**

9 things, each named on this page: Diagnosing the cause and choosing what answers it; Ground and path levels, gutters, downpipes and render that bridge the DPC, and their repair; Leaking pipes, and condensation and its causes in the room's air; Decay in joists, lintels, floors or timber grounds (flagged); A drained channel and sump at the foot of the floor; Moving a socket to a new place; Any promise that the wall stays dry; The party structure notice to a neighbour, and any award or agreement under the 1996 Act, which are the owner's to serve and settle; Dehumidifiers and temporary heaters beyond the job's own.

**Can I check a quote for this job against the takeoff?**

Yes. The damp proofing and replastering quote check reads a quote's lines against these same calculators and your measurements, and reports what it leaves out, what it adds and what to ask. It reads quantities, never prices.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/takeoff/damp-remediation` describes it; `https://api.craftquantities.com/v1/takeoff/damp-remediation/run` works it, measurements with their units.
- MCP: the `get_takeoff` and `run_takeoff` tools at https://api.craftquantities.com/mcp with `takeoff` `damp-remediation`.

---
Source: https://craftquantities.com/build/damp-remediation/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.