  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "window-heat-loss-savings-calculator",
  "category": "insulation-efficiency",
  "title": "Window Heat Loss Savings Calculator",
  "description": "Estimate the reduction in heat loss from upgrading to lower U-factor windows.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/window-heat-loss-savings-calculator.json",
  "inputCount": 4,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/insulation-efficiency/window-heat-loss-savings-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Window Heat Loss Savings Calculator",
    "version": "1.1.2",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Window Heat Loss Savings Calculator. Version 1.1.2. Sources checked 2026-10-31. https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/",
      "apa": "Craft Quantities. (2026). Window Heat Loss Savings Calculator (Version 1.1.2) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/",
      "harvard": "Craft Quantities (2026) Window Heat Loss Savings Calculator (Version 1.1.2). Available at: https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-window-heat-loss-savings-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Window Heat Loss Savings Calculator},\n  version      = {1.1.2},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/window-heat-loss-savings-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "windowArea",
      "label": "Total Window Area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 10,
      "min": 0.01,
      "max": 200,
      "step": 0.5,
      "help": "The combined area of the windows being replaced."
    },
    {
      "id": "oldUFactor",
      "label": "Current Window U-Factor (BTU/hr·ft²·°F)",
      "type": "number",
      "defaultValue": 1,
      "min": 0.1,
      "max": 1.3,
      "step": 0.01,
      "help": "Lower U-factor means better insulation — check the window's label or use a typical value for its type."
    },
    {
      "id": "newUFactor",
      "label": "New Window U-Factor",
      "type": "number",
      "defaultValue": 0.3,
      "min": 0.1,
      "max": 1.3,
      "step": 0.01,
      "help": "The U-factor of the replacement windows, from their NFRC label."
    },
    {
      "id": "designTempDiff",
      "label": "Design Temperature Difference",
      "type": "number",
      "dimension": "tempdelta",
      "defaultValue": 27.78,
      "min": 3,
      "max": 56,
      "step": 0.5,
      "help": "The typical indoor-to-outdoor temperature difference on a cold winter day."
    }
  ],
  "sources": [
    {
      "label": "Standard heat loss formula: Q = U x Area x temperature difference; savings = (U-old - U-new) x window area x design temperature difference"
    }
  ],
  "testCases": [
    {
      "name": "10m² window area, U1.0 to U0.3, 50°F diff",
      "inputs": {
        "windowArea": 10,
        "oldUFactor": 1,
        "newUFactor": 0.3,
        "designTempDiff": 27.7777778
      },
      "expected": 3767.4,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/hr reduction",
      "confidence": "medium",
      "steps": [
        {
          "label": "U-factor improvement",
          "value": 0.7,
          "unit": "U"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "20m² window area, U0.9 to U0.25, 60°F diff",
      "inputs": {
        "windowArea": 20,
        "oldUFactor": 0.9,
        "newUFactor": 0.25,
        "designTempDiff": 33.3333333
      },
      "expected": 8395.9,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/hr reduction",
      "confidence": "medium",
      "steps": [
        {
          "label": "U-factor improvement",
          "value": 0.65,
          "unit": "U"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "window-replacement",
      "name": "Window replacement"
    }
  ]
}