  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "wet-room-tanking-calculator",
  "category": "materials-quantities",
  "title": "Wet Room Tanking and Waterproof Membrane Calculator",
  "description": "Membrane, primer and reinforcing tape for a wet room — in two coats, and with the junctions counted separately, because that is where tanking fails.",
  "url": "https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/wet-room-tanking-calculator.json",
  "inputCount": 5,
  "testCaseCount": 3,
  "sourceCount": 3,
  "lastVerified": "2026-09-26",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/wet-room-tanking-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Wet Room Tanking and Waterproof Membrane Calculator",
    "version": "1.1.0",
    "sourcesChecked": "2026-09-26",
    "url": "https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Wet Room Tanking and Waterproof Membrane Calculator. Version 1.1.0. Sources checked 2026-09-26. https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/",
      "apa": "Craft Quantities. (2026). Wet Room Tanking and Waterproof Membrane Calculator (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/",
      "harvard": "Craft Quantities (2026) Wet Room Tanking and Waterproof Membrane Calculator (Version 1.1.0). Available at: https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-wet-room-tanking-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Wet Room Tanking and Waterproof Membrane Calculator},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/wet-room-tanking-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "wallArea",
      "label": "Wall area inside the wet zone",
      "type": "number",
      "dimension": "area",
      "defaultValue": 12,
      "min": 0.5,
      "max": 200,
      "step": 0.5,
      "help": "Only the walls the membrane actually has to reach."
    },
    {
      "id": "floorArea",
      "label": "Floor area to be tanked",
      "type": "number",
      "dimension": "area",
      "defaultValue": 4,
      "min": 0.5,
      "max": 100,
      "step": 0.5,
      "help": "The whole floor in a wet room, not only the shower end."
    },
    {
      "id": "coverageRate",
      "label": "Membrane coverage, per coat",
      "type": "number",
      "dimension": "coverage",
      "defaultValue": 1,
      "min": 0.2,
      "max": 5,
      "step": 0.05,
      "help": "The area one unit of membrane covers in a single coat, from the tin."
    },
    {
      "id": "junctionLength",
      "label": "Length of internal junctions",
      "type": "number",
      "dimension": "length",
      "defaultValue": 9,
      "min": 0,
      "max": 200,
      "step": 0.5,
      "help": "Wall-to-floor and wall-to-wall lines that take reinforcing tape."
    },
    {
      "id": "penetrations",
      "label": "Pipe and outlet penetrations",
      "type": "number",
      "defaultValue": 3,
      "min": 0,
      "max": 40,
      "step": 1,
      "help": "Every pipe, valve body and waste that breaks the membrane."
    }
  ],
  "sources": [
    {
      "label": "Liquid-applied tanking is specified in two coats, the second laid at right angles to the first, and every published coverage rate is PER COAT — so the area is doubled before it is divided by the rate"
    },
    {
      "label": "Reinforcing tape or matting is bedded into the first coat at every internal junction — wall to floor, wall to wall — and a preformed collar at every pipe penetration, because a membrane bridging a moving junction unsupported is the joint that splits first"
    },
    {
      "label": "Primer is required on absorbent substrates such as plaster, render and sand-cement screed, and is commonly omitted on cement-based tile backer board; the manufacturer's sheet governs which applies"
    }
  ],
  "testCases": [
    {
      "name": "12 m² of wall and 4 m² of floor at 1 m²/L per coat",
      "inputs": {
        "wallArea": 12,
        "floorArea": 4,
        "coverageRate": 1,
        "junctionLength": 9,
        "penetrations": 3
      },
      "expected": 8.5,
      "toleranceDecimalPlaces": 2,
      "unit": "gal",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total area tanked",
          "value": 172.22256666735555,
          "unit": "sq ft"
        },
        {
          "label": "Area covered, at two coats",
          "value": 344.4451333347111,
          "unit": "sq ft"
        },
        {
          "label": "Reinforcing tape, laps included",
          "value": 32.48031496062992,
          "unit": "ft"
        },
        {
          "label": "Preformed collars",
          "value": 3,
          "unit": "collars"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A thirstier substrate at 0.7 m² per litre",
      "inputs": {
        "wallArea": 12,
        "floorArea": 4,
        "coverageRate": 0.7,
        "junctionLength": 9,
        "penetrations": 3
      },
      "expected": 12.1,
      "toleranceDecimalPlaces": 2,
      "unit": "gal",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total area tanked",
          "value": 172.22256666735555,
          "unit": "sq ft"
        },
        {
          "label": "Area covered, at two coats",
          "value": 344.4451333347111,
          "unit": "sq ft"
        },
        {
          "label": "Reinforcing tape, laps included",
          "value": 32.48031496062992,
          "unit": "ft"
        },
        {
          "label": "Preformed collars",
          "value": 3,
          "unit": "collars"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "A tray installation with far less floor tanked",
      "inputs": {
        "wallArea": 9,
        "floorArea": 1,
        "coverageRate": 1,
        "junctionLength": 6,
        "penetrations": 2
      },
      "expected": 5.3,
      "toleranceDecimalPlaces": 2,
      "unit": "gal",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total area tanked",
          "value": 107.63910416709722,
          "unit": "sq ft"
        },
        {
          "label": "Area covered, at two coats",
          "value": 215.27820833419443,
          "unit": "sq ft"
        },
        {
          "label": "Reinforcing tape, laps included",
          "value": 21.653543307086615,
          "unit": "ft"
        },
        {
          "label": "Preformed collars",
          "value": 2,
          "unit": "collars"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    }
  ],
  "usedByAssemblies": [
    {
      "id": "shower-enclosure",
      "name": "Shower enclosure"
    },
    {
      "id": "wet-room-tanking",
      "name": "Wet-room tanking"
    }
  ]
}