  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "watts-amps-kva-calculator",
  "category": "electrical",
  "title": "Watts, Amps and kVA Calculator (Any Voltage, AC or DC)",
  "description": "Convert watts to amps, amps to watts, or kVA to amps at any voltage — DC, single-phase or three-phase AC, with the power factor you enter.",
  "url": "https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/watts-amps-kva-calculator.json",
  "inputCount": 9,
  "testCaseCount": 15,
  "sourceCount": 4,
  "lastVerified": "2026-10-05",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/electrical/watts-amps-kva-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Watts, Amps and kVA Calculator (Any Voltage, AC or DC)",
    "version": "1.0.0",
    "sourcesChecked": "2026-10-05",
    "url": "https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Watts, Amps and kVA Calculator (Any Voltage, AC or DC). Version 1.0.0. Sources checked 2026-10-05. https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/",
      "apa": "Craft Quantities. (2026). Watts, Amps and kVA Calculator (Any Voltage, AC or DC) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/",
      "harvard": "Craft Quantities (2026) Watts, Amps and kVA Calculator (Any Voltage, AC or DC) (Version 1.0.0). Available at: https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-watts-amps-kva-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Watts, Amps and kVA Calculator (Any Voltage, AC or DC)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/watts-amps-kva-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "supply",
      "label": "Supply",
      "type": "select",
      "defaultValue": "ac",
      "options": [
        {
          "value": "ac",
          "label": "AC (mains)"
        },
        {
          "value": "dc",
          "label": "DC (battery, solar, DC bus)"
        }
      ],
      "help": "Alternating current from the mains or a generator, or direct current from a battery, a solar array or a DC bus."
    },
    {
      "id": "phase",
      "label": "Phases",
      "type": "select",
      "defaultValue": "single",
      "options": [
        {
          "value": "single",
          "label": "Single phase"
        },
        {
          "value": "three",
          "label": "Three phase, balanced"
        }
      ],
      "help": "Single phase for houses and most appliances; three phase for larger commercial and industrial loads."
    },
    {
      "id": "voltage",
      "label": "Voltage",
      "type": "select",
      "defaultValue": "240",
      "options": [
        {
          "value": "12",
          "label": "12 V (battery and low-voltage lighting)"
        },
        {
          "value": "24",
          "label": "24 V (battery and control circuits)"
        },
        {
          "value": "48",
          "label": "48 V (battery and solar storage)"
        },
        {
          "value": "120",
          "label": "120 V (North American receptacle circuit)"
        },
        {
          "value": "208",
          "label": "208 V (North American three-phase wye, line to line)"
        },
        {
          "value": "230",
          "label": "230 V (UK, European and Australian single phase)"
        },
        {
          "value": "240",
          "label": "240 V (North American dryer, range, EV charger or heat pump circuit)"
        },
        {
          "value": "277",
          "label": "277 V (North American commercial lighting, line to neutral)"
        },
        {
          "value": "400",
          "label": "400 V (UK, European and Australian three phase, line to line)"
        },
        {
          "value": "415",
          "label": "415 V (older 240/415 V three phase, line to line)"
        },
        {
          "value": "480",
          "label": "480 V (North American three phase, line to line)"
        },
        {
          "value": "other",
          "label": "Another voltage — type it"
        }
      ],
      "help": "The supply's nominal voltage — for three phase, the voltage between two lines."
    },
    {
      "id": "customVoltage",
      "label": "Voltage you are working at (V)",
      "type": "number",
      "defaultValue": 220,
      "min": 1,
      "max": 1500,
      "step": 1,
      "help": "Any voltage the quick picks do not list, in volts."
    },
    {
      "id": "known",
      "label": "What you know",
      "type": "select",
      "defaultValue": "watts",
      "options": [
        {
          "value": "watts",
          "label": "The power in watts — find the amps"
        },
        {
          "value": "amps",
          "label": "The current in amps — find the watts"
        },
        {
          "value": "kva",
          "label": "The apparent power in kVA — find the amps"
        }
      ],
      "help": "The figure on the nameplate, the datasheet or the meter: watts, amps, or kVA."
    },
    {
      "id": "watts",
      "label": "Power (W)",
      "type": "number",
      "defaultValue": 7200,
      "min": 0,
      "max": 2000000,
      "step": 10,
      "help": "The real power in watts, from the rating plate or a data sheet."
    },
    {
      "id": "amps",
      "label": "Current (A)",
      "type": "number",
      "defaultValue": 32,
      "min": 0,
      "max": 10000,
      "step": 0.1,
      "help": "The current in amps: the nameplate's running current or a clamp-meter reading."
    },
    {
      "id": "kva",
      "label": "Apparent power (kVA)",
      "type": "number",
      "defaultValue": 10,
      "min": 0,
      "max": 100000,
      "step": 0.1,
      "help": "The kVA rating of a generator, transformer, UPS or supply."
    },
    {
      "id": "powerFactor",
      "label": "Power factor",
      "type": "number",
      "defaultValue": 1,
      "min": 0.2,
      "max": 1,
      "step": 0.01,
      "help": "1 for heaters, kettles and incandescent lamps; lower for motors and inductive loads."
    }
  ],
  "sources": [
    {
      "label": "Definitions of real, apparent and reactive power: DC P = V × I; single-phase S = V × I and P = V × I × PF; three-phase S = √3 × V(line-to-line) × I and P = √3 × V × I × PF for a balanced load; Q = S × √(1 − PF²)"
    },
    {
      "label": "Balanced three-phase systems: the line-to-line voltage is √3 times the line-to-neutral voltage (phases 120° apart), so three loads at V/√3 each draw √3 × V × I in total"
    },
    {
      "label": "WEG Rolled Steel General Purpose 1-phase Motors, performance data (AutomationDirect catalogue page tMTR-54): the four-pole motors from 1/4 to 1 hp at full-load power factors of 0.59 to 0.68; the 1 hp motors listed at 6.8 A (1,745 rpm, 71.0%, 0.68) and 5.06 A (3,500 rpm, 70.0%, 0.92) on 230 V",
      "url": "https://cdn.automationdirect.com/static/specs/weg1phmotor.pdf"
    },
    {
      "label": "WEG W22 Single-Phase Electric Motor, Commercial Catalogue, European Market (Cod. 50069268, Rev. 00, 01/2017), page 5: motors with start and run capacitors, 0.18 to 9.2 kW, at full-load power factors of 0.75 to 0.99",
      "url": "https://static.weg.net/medias/downloadcenter/h52/h99/WEG-w22-single-phase-european-market-50069268-brochure-english-web.pdf"
    }
  ],
  "testCases": [
    {
      "name": "the opening: 7,200 W on a 240 V single-phase circuit draws 30 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "240",
        "known": "watts",
        "watts": 7200,
        "powerFactor": 1
      },
      "expected": 30,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 7.2,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 240,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "the same 7,200 W at 230 V draws 31.30 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "230",
        "known": "watts",
        "watts": 7200,
        "powerFactor": 1
      },
      "expected": 31.304348,
      "toleranceDecimalPlaces": 5,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 7.2,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "the EV worked example: 48 A at 240 V is 11,520 W",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "240",
        "known": "amps",
        "amps": 48,
        "powerFactor": 1
      },
      "expected": 11520,
      "toleranceDecimalPlaces": 6,
      "unit": "W",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 11.52,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 240,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "10 kVA at 400 V single phase is 25 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "400",
        "known": "kva",
        "kva": 10,
        "powerFactor": 0.8
      },
      "expected": 25,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Real power",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Reactive power",
          "value": 5.999999999999999,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 400,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.8
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "the same 10 kVA at 400 V three phase is 14.43 A in each line",
      "inputs": {
        "supply": "ac",
        "phase": "three",
        "voltage": "400",
        "known": "kva",
        "kva": 10,
        "powerFactor": 0.8
      },
      "expected": 14.433757,
      "toleranceDecimalPlaces": 5,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Real power",
          "value": 8,
          "unit": "kW"
        },
        {
          "label": "Reactive power",
          "value": 5.999999999999999,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 400,
          "unit": "V"
        },
        {
          "label": "Line-to-neutral voltage, V ÷ √3",
          "value": 230.94010767585033,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.8
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "a power factor of 0.8 raises 7,200 W at 240 V to 37.5 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "240",
        "known": "watts",
        "watts": 7200,
        "powerFactor": 0.8
      },
      "expected": 37.5,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 9,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 5.3999999999999995,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 240,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.8
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "a typed 220 V: 2,200 W draws 10 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "other",
        "customVoltage": 220,
        "known": "watts",
        "watts": 2200,
        "powerFactor": 1
      },
      "expected": 10,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 2.2,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 220,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "DC: 1,200 W from a 48 V bank draws 25 A, whatever the power factor box says",
      "inputs": {
        "supply": "dc",
        "phase": "three",
        "voltage": "48",
        "known": "watts",
        "watts": 1200,
        "powerFactor": 0.5
      },
      "expected": 25,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 1.2,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 48,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "480 V three phase, 100 A at 0.85: 70,668 W",
      "inputs": {
        "supply": "ac",
        "phase": "three",
        "voltage": "480",
        "known": "amps",
        "amps": 100,
        "powerFactor": 0.85
      },
      "expected": 70667.67,
      "toleranceDecimalPlaces": 1,
      "unit": "W",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 83.1384387633061,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 43.795890218147186,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 480,
          "unit": "V"
        },
        {
          "label": "Line-to-neutral voltage, V ÷ √3",
          "value": 277.1281292110204,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.85
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "agrees with the fixed 120 V page: 1,500 W is 12.5 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "120",
        "known": "watts",
        "watts": 1500,
        "powerFactor": 1
      },
      "expected": 12.5,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 1.5,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 120,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "12 V DC: a 60 W lamp draws 5 A",
      "inputs": {
        "supply": "dc",
        "phase": "single",
        "voltage": "12",
        "known": "watts",
        "watts": 60,
        "powerFactor": 1
      },
      "expected": 5,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 0.06,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 12,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "24 V DC: 240 W draws 10 A",
      "inputs": {
        "supply": "dc",
        "phase": "single",
        "voltage": "24",
        "known": "watts",
        "watts": 240,
        "powerFactor": 1
      },
      "expected": 10,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 0.24,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 24,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "208 V three phase: 10 kVA is 27.76 A in each line",
      "inputs": {
        "supply": "ac",
        "phase": "three",
        "voltage": "208",
        "known": "kva",
        "kva": 10,
        "powerFactor": 0.9
      },
      "expected": 27.757224,
      "toleranceDecimalPlaces": 5,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Real power",
          "value": 9,
          "unit": "kW"
        },
        {
          "label": "Reactive power",
          "value": 4.358898943540673,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 208,
          "unit": "V"
        },
        {
          "label": "Line-to-neutral voltage, V ÷ √3",
          "value": 120.08885599144216,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.9
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "277 V lighting: 2,770 W at a power factor of 1 is 10 A",
      "inputs": {
        "supply": "ac",
        "phase": "single",
        "voltage": "277",
        "known": "watts",
        "watts": 2770,
        "powerFactor": 1
      },
      "expected": 10,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 2.77,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 0,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 277,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 1
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "415 V three phase: 100 A at 0.8 is 57,504 W",
      "inputs": {
        "supply": "ac",
        "phase": "three",
        "voltage": "415",
        "known": "amps",
        "amps": 100,
        "powerFactor": 0.8
      },
      "expected": 57504.087,
      "toleranceDecimalPlaces": 2,
      "unit": "W",
      "confidence": "high",
      "steps": [
        {
          "label": "Apparent power",
          "value": 71.8801085141084,
          "unit": "kVA"
        },
        {
          "label": "Reactive power",
          "value": 43.12806510846503,
          "unit": "kvar"
        },
        {
          "label": "Voltage used",
          "value": 415,
          "unit": "V"
        },
        {
          "label": "Line-to-neutral voltage, V ÷ √3",
          "value": 239.6003617136947,
          "unit": "V"
        },
        {
          "label": "Power factor used",
          "value": 0.8
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    }
  ]
}