  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "water-heater-recovery-time-calculator",
  "category": "plumbing-hvac",
  "title": "Water Heater Recovery Time Calculator",
  "description": "Estimate how long a storage water heater takes to reheat a full tank after it's been drawn down.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/water-heater-recovery-time-calculator.json",
  "inputCount": 5,
  "testCaseCount": 4,
  "sourceCount": 1,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/water-heater-recovery-time-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Water Heater Recovery Time Calculator",
    "version": "1.1.2",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Water Heater Recovery Time Calculator. Version 1.1.2. Sources checked 2026-10-31. https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/",
      "apa": "Craft Quantities. (2026). Water Heater Recovery Time Calculator (Version 1.1.2) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/",
      "harvard": "Craft Quantities (2026) Water Heater Recovery Time Calculator (Version 1.1.2). Available at: https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-water-heater-recovery-time-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Water Heater Recovery Time Calculator},\n  version      = {1.1.2},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/water-heater-recovery-time-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "tankVolume",
      "label": "Tank Capacity",
      "type": "number",
      "dimension": "volume",
      "defaultValue": 189,
      "min": 0.1,
      "max": 380,
      "step": 1,
      "help": "The rated storage capacity of your water heater, in the unit shown."
    },
    {
      "id": "incomingTemp",
      "label": "Incoming Water Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 10,
      "min": 0,
      "max": 27,
      "step": 0.5,
      "help": "The temperature of the cold water feeding the tank."
    },
    {
      "id": "targetTemp",
      "label": "Target Water Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 49,
      "min": 38,
      "max": 71,
      "step": 0.5,
      "help": "The thermostat setting on the water heater."
    },
    {
      "id": "heaterPower",
      "label": "Burner/Element Power Input",
      "type": "number",
      "dimension": "thermal",
      "defaultValue": 11723,
      "min": 800,
      "max": 30000,
      "step": 100,
      "help": "The heater's rated power input, from its data plate, in the unit shown."
    },
    {
      "id": "recoveryEfficiency",
      "label": "Recovery efficiency",
      "type": "number",
      "defaultValue": 0.75,
      "min": 0.5,
      "max": 1,
      "step": 0.01,
      "help": "How much of the input energy actually ends up in the water."
    }
  ],
  "sources": [
    {
      "label": "Standard recovery formula: recovery rate = (power input × recovery efficiency) ÷ (8.33 BTU/gal·°F × temperature rise); recovery time = tank capacity ÷ recovery rate. Efficiency is 0.75 for a gas storage heater, near 1.0 for an immersion element or an indirect coil. Metric inputs convert at the formula's boundary."
    }
  ],
  "testCases": [
    {
      "name": "180 L cylinder, 3 kW immersion, efficiency 1.0",
      "inputs": {
        "tankVolume": 180,
        "incomingTemp": 10,
        "targetTemp": 60,
        "heaterPower": 3000,
        "recoveryEfficiency": 1
      },
      "expected": 209,
      "toleranceDecimalPlaces": -1,
      "unit": "minutes",
      "confidence": "medium",
      "steps": [
        {
          "label": "Recovery rate",
          "value": 0.8614353172415375,
          "unit": "L/min"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "the same cylinder on a gas heater still takes the longer time",
      "inputs": {
        "tankVolume": 180,
        "incomingTemp": 10,
        "targetTemp": 60,
        "heaterPower": 3000,
        "recoveryEfficiency": 0.75
      },
      "expected": 279,
      "toleranceDecimalPlaces": -1,
      "unit": "minutes",
      "confidence": "medium",
      "steps": [
        {
          "label": "Recovery rate",
          "value": 0.646076487931153,
          "unit": "L/min"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "189 L (50 gal) tank, 10°C→48.9°C, 11,723 W (40,000 BTU/hr)",
      "inputs": {
        "tankVolume": 189.2705892,
        "incomingTemp": 10,
        "targetTemp": 48.88888889,
        "heaterPower": 11722.6407
      },
      "expected": 58.31,
      "toleranceDecimalPlaces": 1,
      "unit": "minutes",
      "confidence": "medium",
      "steps": [
        {
          "label": "Recovery rate",
          "value": 3.2458810853650304,
          "unit": "L/min"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "151 L (40 gal) tank, 4.4°C→54.4°C, 10,550 W (36,000 BTU/hr)",
      "inputs": {
        "tankVolume": 151.41647136,
        "incomingTemp": 4.444444444,
        "targetTemp": 54.44444444,
        "heaterPower": 10550.37663
      },
      "expected": 66.64,
      "toleranceDecimalPlaces": 1,
      "unit": "minutes",
      "confidence": "medium",
      "steps": [
        {
          "label": "Recovery rate",
          "value": 2.272116760002208,
          "unit": "L/min"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}