  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "wall-formwork-pressure-calculator",
  "category": "materials-quantities",
  "title": "ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator",
  "description": "Calculate the maximum lateral pressure on wall formwork from ordinary (non-SCC) concrete, using the ACI 347R rate-of-placement formula.",
  "url": "https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/wall-formwork-pressure-calculator.json",
  "inputCount": 5,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/wall-formwork-pressure-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator",
    "version": "1.2.2",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator. Version 1.2.2. Sources checked 2026-10-31. https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/",
      "apa": "Craft Quantities. (2026). ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator (Version 1.2.2) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/",
      "harvard": "Craft Quantities (2026) ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator (Version 1.2.2). Available at: https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-wall-formwork-pressure-calculator,\n  author       = {{Craft Quantities}},\n  title        = {ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator},\n  version      = {1.2.2},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "freshDensity",
      "label": "Concrete Unit Weight",
      "type": "number",
      "dimension": "density",
      "defaultValue": 2402.7695061,
      "min": 1602,
      "max": 3204,
      "step": 1,
      "help": "The fresh concrete's unit weight."
    },
    {
      "id": "pourRate",
      "label": "Rate of Placement R (ft/hr, Vertical Rise at This Form Location, Max 15)",
      "type": "number",
      "defaultValue": 5,
      "min": 1,
      "max": 15,
      "step": 0.5,
      "help": "How fast the concrete surface rises at this form location, in feet per hour."
    },
    {
      "id": "concreteTemperature",
      "label": "Concrete Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 21.1,
      "min": 4,
      "max": 38,
      "step": 0.5,
      "help": "The temperature of the fresh concrete at placement, in °F."
    },
    {
      "id": "cementCoefficient",
      "label": "Cement/Admixture Coefficient Cc (1.0 = Ordinary Cement No Retarder; 1.2 = With Retarder OR High Slag/Fly-Ash No Retarder; 1.4 = High Slag/Fly-Ash WITH Retarder)",
      "type": "select",
      "defaultValue": "1.0",
      "options": [
        {
          "value": "1.0",
          "label": "1.0 — Ordinary Cement, No Retarder"
        },
        {
          "value": "1.2",
          "label": "1.2 — With Retarder OR High Slag/Fly-Ash, No Retarder"
        },
        {
          "value": "1.4",
          "label": "1.4 — High Slag/Fly-Ash WITH Retarder"
        }
      ],
      "help": "ACI 347R Table 2.2 chemistry coefficient for the cement/admixture combination used."
    },
    {
      "id": "wallHeight",
      "label": "Total Wall Pour Height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3,
      "min": 0.01,
      "max": 16,
      "step": 0.1,
      "help": "The total vertical height of the wall being poured."
    }
  ],
  "sources": [
    {
      "label": "ACI 347R-14(21) Guide to Formwork for Concrete, Section 2.2.2, Eq. 2.4 (used across its full 0-15 ft/hr rate range as a single conservative envelope formula, since Eq. 2.3 and 2.4 are continuous and equal at R=7 ft/hr and Eq. 2.4 is always ≥ Eq. 2.3 below that): Pmax = Cw×Cc×[150 + 43400/T + 2800R/T] psf, with a floor of 600×Cw psf and a ceiling of full hydrostatic pressure (w×h). Cw (unit weight coefficient, Table 2.1) = 1.0 for 140-150 pcf concrete. Cc (chemistry coefficient, Table 2.2) = 1.0 for ordinary Type I/II/III cement with no retarder, rising to 1.2-1.4 for retarders or high slag/fly-ash content. This formula ONLY applies when slump ≤ 7 in, placement uses normal internal vibration to a depth ≤4ft, and R≤15 ft/hr — this is DISTINCT from this site's existing SCC formwork pressure calculator, which correctly uses full hydrostatic pressure (ACI 347R Eq. 2.1a) for self-consolidating concrete, since SCC and high-slump/retarded mixes fall outside this reduced formula's applicability and ACI 347R itself directs using full hydrostatic pressure for those cases."
    }
  ],
  "testCases": [
    {
      "name": "150pcf, 5ft/hr, 70°F, Cc=1.0, 15.24m (50ft) wall",
      "inputs": {
        "freshDensity": 2402.7695061,
        "pourRate": 5,
        "concreteTemperature": 21.1111111,
        "cementCoefficient": "1.0",
        "wallHeight": 15.24
      },
      "expected": 970,
      "toleranceDecimalPlaces": -1,
      "unit": "psf",
      "confidence": "medium",
      "steps": [
        {
          "label": "Unit weight coefficient Cw",
          "value": 1,
          "unit": "(dimensionless)"
        },
        {
          "label": "Full hydrostatic ceiling",
          "value": 7499.999999999999,
          "unit": "psf"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "150pcf, 6ft/hr, 60°F, Cc=1.2, 15.24m (50ft) wall",
      "inputs": {
        "freshDensity": 2402.7695061,
        "pourRate": 6,
        "concreteTemperature": 15.5555556,
        "cementCoefficient": "1.2",
        "wallHeight": 15.24
      },
      "expected": 1384,
      "toleranceDecimalPlaces": -1,
      "unit": "psf",
      "confidence": "medium",
      "steps": [
        {
          "label": "Unit weight coefficient Cw",
          "value": 1,
          "unit": "(dimensionless)"
        },
        {
          "label": "Full hydrostatic ceiling",
          "value": 7499.999999999999,
          "unit": "psf"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}