  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "vapor-barrier-dewpoint-calculator",
  "category": "materials-quantities",
  "title": "Vapor Barrier Dew-Point Condensation Risk Calculator",
  "description": "Check whether the temperature at a vapor barrier's location within a wall assembly stays above the interior dew point.",
  "url": "https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/vapor-barrier-dewpoint-calculator.json",
  "inputCount": 5,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Vapor Barrier Dew-Point Condensation Risk Calculator",
    "version": "1.1.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Vapor Barrier Dew-Point Condensation Risk Calculator. Version 1.1.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/",
      "apa": "Craft Quantities. (2026). Vapor Barrier Dew-Point Condensation Risk Calculator (Version 1.1.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/",
      "harvard": "Craft Quantities (2026) Vapor Barrier Dew-Point Condensation Risk Calculator (Version 1.1.1). Available at: https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-vapor-barrier-dewpoint-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Vapor Barrier Dew-Point Condensation Risk Calculator},\n  version      = {1.1.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/vapor-barrier-dewpoint-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "interiorTemp",
      "label": "Interior Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 21,
      "min": 15,
      "max": 25,
      "step": 0.5,
      "help": "The assumed indoor air temperature."
    },
    {
      "id": "exteriorTemp",
      "label": "Exterior Winter Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -10,
      "min": -40,
      "max": 5,
      "step": 0.5,
      "help": "The outdoor winter design temperature for the site's climate zone."
    },
    {
      "id": "totalRValue",
      "label": "Total Assembly R-Value",
      "type": "number",
      "defaultValue": 20,
      "min": 5,
      "max": 60,
      "step": 1,
      "help": "The full wall assembly's total thermal resistance, interior surface to exterior surface."
    },
    {
      "id": "interiorRValue",
      "label": "R-Value from Interior Face to Vapor Barrier Location",
      "type": "number",
      "defaultValue": 5,
      "min": 0,
      "max": 60,
      "step": 1,
      "help": "The portion of the total R-value between the interior face and where the vapor barrier sits."
    },
    {
      "id": "dewPoint",
      "label": "Interior Air Dew Point",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 10,
      "min": -5,
      "max": 20,
      "step": 0.5,
      "help": "The dew point temperature of the interior air, based on its temperature and relative humidity."
    }
  ],
  "sources": [
    {
      "label": "Simplified steady-state temperature gradient method: the temperature at any point within an insulated assembly = interior temp − (R-value from interior to that point ÷ total assembly R-value) × (interior temp − exterior temp); condensation risk exists if this temperature falls below the interior air's dew point"
    }
  ],
  "testCases": [
    {
      "name": "R20 assembly, VB at R5 from interior (pass)",
      "inputs": {
        "interiorTemp": 21,
        "exteriorTemp": -10,
        "totalRValue": 20,
        "interiorRValue": 5,
        "dewPoint": 10
      },
      "expected": 13.25,
      "toleranceDecimalPlaces": 1,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Interior air dew point",
          "value": 10,
          "unit": "°C"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "R15 assembly, VB at R8 from interior (fail)",
      "inputs": {
        "interiorTemp": 21,
        "exteriorTemp": -15,
        "totalRValue": 15,
        "interiorRValue": 8,
        "dewPoint": 12
      },
      "expected": 1.8,
      "toleranceDecimalPlaces": 1,
      "unit": "°C",
      "confidence": "medium",
      "steps": [
        {
          "label": "Interior air dew point",
          "value": 12,
          "unit": "°C"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}