  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "u-value-si-to-imperial-calculator",
  "category": "insulation-efficiency",
  "title": "U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F)",
  "description": "Convert a metric U-value, as UK and European documents state it, into the US U-factor — and see the thermal resistance in both systems beside it.",
  "url": "https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/u-value-si-to-imperial-calculator.json",
  "inputCount": 1,
  "testCaseCount": 3,
  "sourceCount": 2,
  "lastVerified": "2026-09-22",
  "citation": {
    "author": "Craft Quantities",
    "title": "U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F)",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-22",
    "url": "https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F). Version 1.0.0. Sources checked 2026-09-22. https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/",
      "apa": "Craft Quantities. (2026). U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/",
      "harvard": "Craft Quantities (2026) U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F) (Version 1.0.0). Available at: https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/",
      "bibtex": "@misc{craftquantities-calculators-insulation-efficiency-u-value-si-to-imperial-calculator,\n  author       = {{Craft Quantities}},\n  title        = {U-Value Metric to Imperial Converter (W/m²K to BTU/hr·ft²·°F)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/insulation-efficiency/u-value-si-to-imperial-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "uValueSi",
      "label": "U-value (W/m²K)",
      "type": "number",
      "defaultValue": 0.18,
      "min": 0.001,
      "max": 10,
      "step": 0.01,
      "help": "The thermal transmittance in watts per square metre kelvin."
    }
  ],
  "sources": [
    {
      "label": "NIST SP 811, Appendix B: 1 Btu(IT)/(h·ft²·°F) = 5.678 263 W/(m²·K), from the International Table BTU (1055.05585262 J), the foot (0.3048 m) and the Fahrenheit degree (5/9 K)"
    },
    {
      "label": "U = 1 ÷ R in either system, with R the total resistance of the element including its surface resistances"
    }
  ],
  "testCases": [
    {
      "name": "Single glazing at 5.7 W/m²K",
      "inputs": {
        "uValueSi": 5.7
      },
      "expected": 1.003828,
      "toleranceDecimalPlaces": 5,
      "unit": "BTU/hr·ft²·°F",
      "confidence": "high",
      "steps": [
        {
          "label": "W/m²K entered",
          "value": 5.7,
          "unit": "W/m²K"
        },
        {
          "label": "Thermal resistance, RSI (1 ÷ U)",
          "value": 0.17543859649122806,
          "unit": "m²K/W"
        },
        {
          "label": "US R-value (1 ÷ U-factor)",
          "value": 0.9961865510725416,
          "unit": "hr·ft²·°F/BTU"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The cavity-fill guide's 0.30 W/m²K wall",
      "inputs": {
        "uValueSi": 0.3
      },
      "expected": 0.052833,
      "toleranceDecimalPlaces": 5,
      "unit": "BTU/hr·ft²·°F",
      "confidence": "high",
      "steps": [
        {
          "label": "W/m²K entered",
          "value": 0.3,
          "unit": "W/m²K"
        },
        {
          "label": "Thermal resistance, RSI (1 ÷ U)",
          "value": 3.3333333333333335,
          "unit": "m²K/W"
        },
        {
          "label": "US R-value (1 ÷ U-factor)",
          "value": 18.927544470378294,
          "unit": "hr·ft²·°F/BTU"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The sloping-ceiling guide's 0.18 target",
      "inputs": {
        "uValueSi": 0.18
      },
      "expected": 0.0317,
      "toleranceDecimalPlaces": 4,
      "unit": "BTU/hr·ft²·°F",
      "confidence": "high",
      "steps": [
        {
          "label": "W/m²K entered",
          "value": 0.18,
          "unit": "W/m²K"
        },
        {
          "label": "Thermal resistance, RSI (1 ÷ U)",
          "value": 5.555555555555555,
          "unit": "m²K/W"
        },
        {
          "label": "US R-value (1 ÷ U-factor)",
          "value": 31.545907450630484,
          "unit": "hr·ft²·°F/BTU"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}