  "title": "Mass Timber Char Depth & Residual Section Calculator",
  "description": "What a fire period takes off an exposed timber member, notional char plus the zero-strength layer, and the residual section and sanding margin it leaves.",
  "url": "https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/timber-char-depth-calculator.json",
  "inputCount": 6,
  "testCaseCount": 2,
  "sourceCount": 3,
  "lastVerified": "2026-08-30",
  "citation": {
    "author": "Craft Quantities",
    "title": "Mass Timber Char Depth & Residual Section Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-08-30",
    "url": "https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Mass Timber Char Depth & Residual Section Calculator. Version 1.0.0. Sources checked 2026-08-30. https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/",
      "apa": "Craft Quantities. (2026). Mass Timber Char Depth & Residual Section Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/",
      "harvard": "Craft Quantities (2026) Mass Timber Char Depth & Residual Section Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-timber-char-depth-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Mass Timber Char Depth & Residual Section Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/timber-char-depth-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "fireResistancePeriod",
      "label": "Required Fire-Resistance Period (minutes)",
      "type": "number",
      "defaultValue": 60,
      "min": 15,
      "max": 240,
      "step": 15,
      "help": "The period the element has to survive under the standard fire, as consented."
    },
    {
      "id": "charringRate",
      "label": "Notional Charring Rate (mm/min)",
      "type": "number",
      "defaultValue": 0.7,
      "min": 0.4,
      "max": 1.2,
      "step": 0.05,
      "help": "The notional rate tabulated for this product and density in the standard you are designing to."
    },
    {
      "id": "zeroStrengthLayer",
      "label": "Zero-Strength Layer Allowance",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.007,
      "min": 0,
      "max": 0.02,
      "step": 0.001,
      "help": "Depth of heat-damaged timber just inside the char line that the reduced cross-section method discounts."
    },
    {
      "id": "memberDimension",
      "label": "Original Section Dimension",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.24,
      "min": 0.05,
      "max": 1.2,
      "step": 0.005,
      "help": "The width, depth or panel thickness being checked, before any fire loss."
    },
    {
      "id": "exposedFaces",
      "label": "Faces Exposed Across This Dimension",
      "type": "select",
      "defaultValue": "2",
      "options": [
        {
          "value": "1",
          "label": "One face — panel, or the depth of a three-sided beam"
        },
        {
          "value": "2",
          "label": "Two faces — the width of a beam, or a four-sided column"
        }
      ],
      "help": "How many opposite faces of this particular dimension the fire can reach."
    },
    {
      "id": "requiredResidualDimension",
      "label": "Minimum Residual Dimension Required",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.12,
      "min": 0.01,
      "max": 1.2,
      "step": 0.005,
      "help": "The smallest residual the engineer's fire check still passes at — from the design, not from this page."
    }
  ],
  "sources": [
    {
      "label": "EN 1995-1-2 (Eurocode 5, Part 1-2: Structural fire design) reduced cross-section method: char depth is the product's notional charring rate times the fire-resistance period, with a zero-strength layer deducted in addition. Both the rate and the layer are entered here from the standard governing your design — this page publishes neither"
    },
    {
      "label": "The National Design Specification for Wood Construction, Chapter 16, gives the equivalent char provisions used in US practice; its charring model and its allowance differ from the Eurocode one, so take both figures from a single document rather than mixing the two"
    },
    {
      "label": "Sanding removes material from the same surface the char depth is measured inward from, so any thickness taken off comes straight out of the residual section — the arithmetic on this page is that subtraction and nothing more"
    }
  ],
  "testCases": [
    {
      "name": "240 mm glulam width, 60 minutes at 0.7 mm/min, 7 mm zero-strength layer, two faces",
      "inputs": {
        "fireResistancePeriod": 60,
        "charringRate": 0.7,
        "zeroStrengthLayer": 0.007,
        "memberDimension": 0.24,
        "exposedFaces": "2",
        "requiredResidualDimension": 0.12
      },
      "expected": 142,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "medium",
      "steps": [
        {
          "label": "Notional char depth",
          "value": 42,
          "unit": "mm"
        },
        {
          "label": "Effective loss per exposed face",
          "value": 49,
          "unit": "mm"
        },
        {
          "label": "Surface removable before the residual reaches the required minimum",
          "value": 22,
          "unit": "mm"
        },
        {
          "label": "Proportion of the original dimension surviving",
          "value": 59.166666666666664,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "400 mm depth, 90 minutes at 0.8 mm/min, 7 mm zero-strength layer, one face",
      "inputs": {
        "fireResistancePeriod": 90,
        "charringRate": 0.8,
        "zeroStrengthLayer": 0.007,
        "memberDimension": 0.4,
        "exposedFaces": "1",
        "requiredResidualDimension": 0.12
      },
      "expected": 321,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "medium",
      "steps": [
        {
          "label": "Notional char depth",
          "value": 72,
          "unit": "mm"
        },
        {
          "label": "Effective loss per exposed face",
          "value": 79,
          "unit": "mm"
        },
        {
          "label": "Surface removable before the residual reaches the required minimum",
          "value": 201,
          "unit": "mm"
        },
        {
          "label": "Proportion of the original dimension surviving",
          "value": 80.25,
          "unit": "%"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}