  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "tankless-water-heater-calculator",
  "category": "plumbing-hvac",
  "title": "Tankless Water Heater Sizing Calculator",
  "description": "Size an instantaneous water heater from simultaneous flow and the temperature rise your incoming water actually needs.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/tankless-water-heater-calculator.json",
  "inputCount": 3,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Tankless Water Heater Sizing Calculator",
    "version": "1.1.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Tankless Water Heater Sizing Calculator. Version 1.1.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/",
      "apa": "Craft Quantities. (2026). Tankless Water Heater Sizing Calculator (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/",
      "harvard": "Craft Quantities (2026) Tankless Water Heater Sizing Calculator (Version 1.1.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-tankless-water-heater-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Tankless Water Heater Sizing Calculator},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/tankless-water-heater-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "flowRate",
      "label": "Simultaneous flow",
      "type": "number",
      "dimension": "flow",
      "defaultValue": 12,
      "min": 1,
      "max": 200,
      "step": 0.5,
      "help": "Total flow of the fixtures used at once."
    },
    {
      "id": "incomingTempC",
      "label": "Incoming water temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 10,
      "min": -2,
      "max": 30,
      "step": 1,
      "help": "Cold mains temperature in winter."
    },
    {
      "id": "outletTempC",
      "label": "Delivered temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 42,
      "min": 25,
      "max": 80,
      "step": 1,
      "help": "Temperature at the outlet."
    }
  ],
  "sources": [
    {
      "label": "Q = ṁ · c · ΔT. For water: kW = L/min × ΔT × 0.0698 (from 4.186 kJ/kg·K)"
    },
    {
      "label": "Typical fixture flows: shower 7-11 L/min, basin 4-6, kitchen sink 6-9 — WaterSense and UK Water Regulations fittings data"
    }
  ],
  "testCases": [
    {
      "name": "12 L/min from 10 to 42 °C",
      "inputs": {
        "flowRate": 12,
        "incomingTempC": 10,
        "outletTempC": 42
      },
      "expected": 26.79,
      "toleranceDecimalPlaces": 2,
      "unit": "kW",
      "confidence": "high",
      "steps": [
        {
          "label": "Temperature rise",
          "value": 32,
          "unit": "K"
        },
        {
          "label": "BTU/h",
          "value": 91412.63920815151,
          "unit": "BTU/h"
        },
        {
          "label": "Flow in US GPM",
          "value": 3.170064628297781,
          "unit": "GPM"
        },
        {
          "label": "Flow in gallons per hour",
          "value": 190.20387769786686,
          "unit": "GPH"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Colder mains needs more power",
      "inputs": {
        "flowRate": 12,
        "incomingTempC": 4,
        "outletTempC": 42
      },
      "expected": 31.81,
      "toleranceDecimalPlaces": 1,
      "unit": "kW",
      "confidence": "high",
      "steps": [
        {
          "label": "Temperature rise",
          "value": 38,
          "unit": "K"
        },
        {
          "label": "BTU/h",
          "value": 108552.50905967993,
          "unit": "BTU/h"
        },
        {
          "label": "Flow in US GPM",
          "value": 3.170064628297781,
          "unit": "GPM"
        },
        {
          "label": "Flow in gallons per hour",
          "value": 190.20387769786686,
          "unit": "GPH"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Half the flow, half the power",
      "inputs": {
        "flowRate": 6,
        "incomingTempC": 10,
        "outletTempC": 42
      },
      "expected": 13.4,
      "toleranceDecimalPlaces": 1,
      "unit": "kW",
      "confidence": "high",
      "steps": [
        {
          "label": "Temperature rise",
          "value": 32,
          "unit": "K"
        },
        {
          "label": "BTU/h",
          "value": 45706.319604075754,
          "unit": "BTU/h"
        },
        {
          "label": "Flow in US GPM",
          "value": 1.5850323141488905,
          "unit": "GPM"
        },
        {
          "label": "Flow in gallons per hour",
          "value": 95.10193884893343,
          "unit": "GPH"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "No rise needs no power",
      "inputs": {
        "flowRate": 12,
        "incomingTempC": 42,
        "outletTempC": 42
      },
      "expected": 0,
      "toleranceDecimalPlaces": 8,
      "unit": "kW",
      "confidence": "high",
      "steps": [
        {
          "label": "Temperature rise",
          "value": 0,
          "unit": "K"
        },
        {
          "label": "BTU/h",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Flow in US GPM",
          "value": 3.170064628297781,
          "unit": "GPM"
        },
        {
          "label": "Flow in gallons per hour",
          "value": 190.20387769786686,
          "unit": "GPH"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}