  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "static-pressure-drop-calculator",
  "category": "plumbing-hvac",
  "title": "Duct Static Pressure Calculator",
  "description": "Add up total external static pressure across a duct system and check it against the blower's rating.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/static-pressure-drop-calculator.json",
  "inputCount": 4,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/static-pressure-drop-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Duct Static Pressure Calculator",
    "version": "1.1.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Duct Static Pressure Calculator. Version 1.1.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/",
      "apa": "Craft Quantities. (2026). Duct Static Pressure Calculator (Version 1.1.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/",
      "harvard": "Craft Quantities (2026) Duct Static Pressure Calculator (Version 1.1.1). Available at: https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-static-pressure-drop-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Duct Static Pressure Calculator},\n  version      = {1.1.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/static-pressure-drop-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "ductRun",
      "label": "Longest duct run",
      "type": "number",
      "dimension": "length",
      "defaultValue": 30.48,
      "min": 0.01,
      "max": 2000,
      "step": 5,
      "help": "Supply plus return, along the longest path."
    },
    {
      "id": "fittingEquivalent",
      "label": "Fitting equivalent length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 45.72,
      "min": 0,
      "max": 3000,
      "step": 5,
      "help": "Elbows, takeoffs, boots and transitions, expressed as the equivalent length of straight duct."
    },
    {
      "id": "frictionRate",
      "label": "Friction rate (in w.g. per 100 ft)",
      "type": "number",
      "defaultValue": 0.1,
      "min": 0.01,
      "max": 1,
      "step": 0.01,
      "help": "Design friction rate for the ductwork."
    },
    {
      "id": "componentDrop",
      "label": "Filter, coil and register drop (in w.g.)",
      "type": "number",
      "defaultValue": 0.25,
      "min": 0,
      "max": 2,
      "step": 0.01,
      "help": "Everything that is not duct."
    }
  ],
  "sources": [
    {
      "label": "ACCA Manual D — total effective length method; friction rate = available static pressure ÷ (TEL/100)"
    },
    {
      "label": "Residential air handlers are commonly rated at 0.5 in w.g. total external static pressure"
    }
  ],
  "testCases": [
    {
      "name": "100 ft run, 150 ft fittings, 0.10, 0.25 components",
      "inputs": {
        "ductRun": 30.48,
        "fittingEquivalent": 45.72,
        "frictionRate": 0.1,
        "componentDrop": 0.25
      },
      "expected": 0.5,
      "toleranceDecimalPlaces": 2,
      "unit": "in w.g.",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total effective length",
          "value": 249.99999999999994,
          "unit": "ft"
        },
        {
          "label": "Duct friction loss",
          "value": 0.24999999999999997,
          "unit": "in w.g."
        },
        {
          "label": "Components",
          "value": 0.25,
          "unit": "in w.g."
        },
        {
          "label": "Pascals",
          "value": 124.54445,
          "unit": "Pa"
        },
        {
          "label": "Against a 0.5 in w.g. blower rating",
          "value": 100,
          "unit": "% of rating"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "More fittings raise the total",
      "inputs": {
        "ductRun": 30.48,
        "fittingEquivalent": 121.92,
        "frictionRate": 0.1,
        "componentDrop": 0.25
      },
      "expected": 0.75,
      "toleranceDecimalPlaces": 2,
      "unit": "in w.g.",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total effective length",
          "value": 499.99999999999994,
          "unit": "ft"
        },
        {
          "label": "Duct friction loss",
          "value": 0.49999999999999994,
          "unit": "in w.g."
        },
        {
          "label": "Components",
          "value": 0.25,
          "unit": "in w.g."
        },
        {
          "label": "Pascals",
          "value": 186.816675,
          "unit": "Pa"
        },
        {
          "label": "Against a 0.5 in w.g. blower rating",
          "value": 150,
          "unit": "% of rating"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A lower friction rate needs bigger ducts but drops pressure",
      "inputs": {
        "ductRun": 30.48,
        "fittingEquivalent": 45.72,
        "frictionRate": 0.06,
        "componentDrop": 0.25
      },
      "expected": 0.4,
      "toleranceDecimalPlaces": 2,
      "unit": "in w.g.",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total effective length",
          "value": 249.99999999999994,
          "unit": "ft"
        },
        {
          "label": "Duct friction loss",
          "value": 0.14999999999999997,
          "unit": "in w.g."
        },
        {
          "label": "Components",
          "value": 0.25,
          "unit": "in w.g."
        },
        {
          "label": "Pascals",
          "value": 99.63555999999998,
          "unit": "Pa"
        },
        {
          "label": "Against a 0.5 in w.g. blower rating",
          "value": 80,
          "unit": "% of rating"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Components alone with no duct",
      "inputs": {
        "ductRun": 0.3048,
        "fittingEquivalent": 0,
        "frictionRate": 0.1,
        "componentDrop": 0.25
      },
      "expected": 0.251,
      "toleranceDecimalPlaces": 2,
      "unit": "in w.g.",
      "confidence": "medium",
      "steps": [
        {
          "label": "Total effective length",
          "value": 0.9999999999999999,
          "unit": "ft"
        },
        {
          "label": "Duct friction loss",
          "value": 0.0009999999999999998,
          "unit": "in w.g."
        },
        {
          "label": "Components",
          "value": 0.25,
          "unit": "in w.g."
        },
        {
          "label": "Pascals",
          "value": 62.521313899999996,
          "unit": "Pa"
        },
        {
          "label": "Against a 0.5 in w.g. blower rating",
          "value": 50.2,
          "unit": "% of rating"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}