  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "stair-calculator",
  "category": "renovation-construction",
  "title": "Stair Rise & Run Calculator",
  "description": "Divide a total rise into equal risers and set the rise and going beside the US IRC, England's Approved Document K, Australia's NCC or Canada's NBC.",
  "url": "https://craftquantities.com/calculators/renovation-construction/stair-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/stair-calculator.json",
  "inputCount": 6,
  "testCaseCount": 5,
  "sourceCount": 5,
  "lastVerified": "2026-10-31",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/renovation-construction/stair-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Stair Rise & Run Calculator",
    "version": "1.3.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/renovation-construction/stair-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Stair Rise & Run Calculator. Version 1.3.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/renovation-construction/stair-calculator/",
      "apa": "Craft Quantities. (2026). Stair Rise & Run Calculator (Version 1.3.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/renovation-construction/stair-calculator/",
      "harvard": "Craft Quantities (2026) Stair Rise & Run Calculator (Version 1.3.0). Available at: https://craftquantities.com/calculators/renovation-construction/stair-calculator/",
      "bibtex": "@misc{craftquantities-calculators-renovation-construction-stair-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Stair Rise & Run Calculator},\n  version      = {1.3.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/renovation-construction/stair-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "totalRise",
      "label": "Total Rise (floor to floor)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.8,
      "min": 0.01,
      "max": 6,
      "step": 0.01,
      "help": "The total vertical height the staircase needs to climb."
    },
    {
      "id": "targetRiser",
      "label": "Target Riser Height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.185,
      "min": 0.01,
      "max": 0.2032,
      "step": 0.0032,
      "help": "A comfortable target, not a code limit: about 175–190 mm (6.9–7.5 in) suits most house stairs."
    },
    {
      "id": "actualTreadDepth",
      "label": "Planned Tread Depth (Going)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.26,
      "min": 0.01,
      "max": 0.4,
      "step": 0.01,
      "help": "The horizontal depth of each tread (the 'going') you plan to build, front edge to front edge."
    },
    {
      "id": "buildingCode",
      "label": "Building Code Reference",
      "type": "select",
      "defaultValue": "irc",
      "options": [
        {
          "value": "irc",
          "label": "US — IRC 2024 (max 7.75 in riser / min 10 in tread)"
        },
        {
          "value": "uk",
          "label": "UK — Approved Document K (max 220 mm rise / min 220 mm going)"
        },
        {
          "value": "au",
          "label": "Australia — NCC Housing Provisions (rise 115–190 mm / going 240–355 mm)"
        },
        {
          "value": "ca",
          "label": "Canada — National Building Code, private stair (rise 125–200 mm / run 255–355 mm)"
        },
        {
          "value": "generic",
          "label": "General best-practice guideline"
        }
      ],
      "help": "Which building code to check your stair design against."
    },
    {
      "id": "headroom",
      "label": "Headroom Over the Flight",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.032,
      "min": 1.5,
      "max": 3,
      "step": 0.01,
      "help": "The clear height you want above the nosing line, which sets how long the floor opening must be."
    },
    {
      "id": "upperFloorDepth",
      "label": "Upper Floor Depth at the Opening",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.3,
      "min": 0,
      "max": 1,
      "step": 0.01,
      "help": "From the finished upper floor down to the ceiling under it, at the edge of the opening."
    }
  ],
  "sources": [
    {
      "label": "Comfortable stair proportion rule of thumb: 2 x riser height + tread depth = 24-25 inches; a riser of about 175–190 mm (6.9–7.5 in) is a comfortable target that sits inside all four codes this page checks"
    },
    {
      "label": "US: IRC 2024 R311.7.5 — maximum riser height 7.75 in, minimum tread depth (going) 10 in"
    },
    {
      "label": "UK: Approved Document K (2013), Section 1, Table 1.1 — a private stair's rise 150–220 mm and going 220–300 mm, pitch at most 42°, and twice the rise plus the going between 550 and 700 mm"
    },
    {
      "label": "Australia: ABCB Housing Provisions Standard, Part 11.2, clause 11.2.2 and Table 11.2.2a, called up by NCC Volume Two for houses; the same table in NCC 2022 and NCC 2025. A stairway other than a spiral stair has risers of 115–190 mm, goings of 240–355 mm and a slope relationship 2R + G of 550–700 mm; each flight has not more than 18 and not less than 2 risers (11.2.2(1)(a)); goings and risers are constant through a flight, within 5 mm between neighbours and 10 mm across the flight (11.2.2(1)(c)); and risers have no opening a 125 mm sphere can pass through (11.2.2(1)(d)). Under 11.2.2(2), a stairway serving only non-habitable rooms such as attics and storerooms that are not used on a regular or daily basis may use Table 11.2.2b instead: riser 130–225 mm, going 215–355 mm and 2R + G 540–700 mm. NCC Volume One, clause D3D14 and Table D3D14, gives a public stairway in other buildings a going of 250–355 mm with the same risers and 2R + G",
      "url": "https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/11-safe-movement-and-access/part-112-stairway-and-ramp-construction"
    },
    {
      "label": "Canada: National Building Code of Canada 2020, Volume 2, Division B, Section 9.8, for a private stair (one serving a single dwelling unit, a house with a secondary suite, or a garage serving either): rise 125–200 mm (Article 9.8.4.1, Table 9.8.4.1), run 255–355 mm (Article 9.8.4.2, Table 9.8.4.2), each tread's depth between its run and its run plus 25 mm (Sentence 9.8.4.2.(2)), risers and runs uniform within 5 mm between neighbours and 10 mm across a flight (Article 9.8.4.4), no flight more than 3.7 m high (Article 9.8.3.3), and 1 950 mm of clear height over a stair serving a single dwelling unit (Sentence 9.8.2.2.(3)). A public stair has a rise of 125–180 mm and a run of at least 280 mm. Provinces and territories adopt the NBC with amendments of their own, so check the edition in force where you build",
      "url": "https://doi.org/10.4224/w324-hv93"
    }
  ],
  "testCases": [
    {
      "name": "The page's opening: 2.8 m total rise, 18.5 cm target riser, 26 cm tread, IRC, inside the limits checked",
      "inputs": {
        "totalRise": 2.8,
        "targetRiser": 0.185,
        "actualTreadDepth": 0.26,
        "buildingCode": "irc"
      },
      "expected": 15,
      "toleranceDecimalPlaces": 0,
      "unit": "risers",
      "confidence": "high",
      "steps": [
        {
          "label": "Actual riser height",
          "value": 7.349081364829394,
          "unit": "in"
        },
        {
          "label": "Number of treads (steps)",
          "value": 14,
          "unit": "treads"
        },
        {
          "label": "Recommended tread depth (comfort formula)",
          "value": 10.301837270341212,
          "unit": "in"
        },
        {
          "label": "Code max riser height (US IRC 2024)",
          "value": 7.75,
          "unit": "in"
        },
        {
          "label": "Code min tread depth (US IRC 2024)",
          "value": 10,
          "unit": "in"
        },
        {
          "label": "Total run of the flight",
          "value": 11.942257217847768,
          "unit": "ft"
        },
        {
          "label": "Floor opening for the headroom",
          "value": 10.656636670416198,
          "unit": "ft"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "3.5m total rise, 7in target riser, UK code, inside the limits checked",
      "inputs": {
        "totalRise": 3.5,
        "targetRiser": 0.1778,
        "actualTreadDepth": 0.28,
        "buildingCode": "uk"
      },
      "expected": 20,
      "toleranceDecimalPlaces": 0,
      "unit": "risers",
      "confidence": "high",
      "steps": [
        {
          "label": "Actual riser height",
          "value": 6.889763779527558,
          "unit": "in"
        },
        {
          "label": "Number of treads (steps)",
          "value": 19,
          "unit": "treads"
        },
        {
          "label": "Recommended tread depth (comfort formula)",
          "value": 11.220472440944883,
          "unit": "in"
        },
        {
          "label": "Code max riser height (UK Approved Document K)",
          "value": 8.661417322834646,
          "unit": "in"
        },
        {
          "label": "Code min tread depth (UK Approved Document K)",
          "value": 8.661417322834646,
          "unit": "in"
        },
        {
          "label": "Stair pitch (Approved Document K maximum 42°)",
          "value": 32.005383208083494,
          "unit": "°"
        },
        {
          "label": "Twice the rise plus the going (Approved Document K)",
          "value": 24.803149606299215,
          "unit": "in"
        },
        {
          "label": "Total run of the flight",
          "value": 17.454068241469816,
          "unit": "ft"
        },
        {
          "label": "Floor opening for the headroom",
          "value": 12.241469816272964,
          "unit": "ft"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "2.7 m rise at a 175 mm target and a 250 mm going, Australian NCC",
      "inputs": {
        "totalRise": 2.7,
        "targetRiser": 0.175,
        "actualTreadDepth": 0.25,
        "buildingCode": "au"
      },
      "expected": 15,
      "toleranceDecimalPlaces": 0,
      "unit": "risers",
      "confidence": "high",
      "steps": [
        {
          "label": "Actual riser height",
          "value": 7.086614173228346,
          "unit": "in"
        },
        {
          "label": "Number of treads (steps)",
          "value": 14,
          "unit": "treads"
        },
        {
          "label": "Recommended tread depth (comfort formula)",
          "value": 10.826771653543307,
          "unit": "in"
        },
        {
          "label": "Code max riser height (Australian NCC Housing Provisions)",
          "value": 7.480314960629921,
          "unit": "in"
        },
        {
          "label": "Code min going (Australian NCC Housing Provisions)",
          "value": 9.448818897637796,
          "unit": "in"
        },
        {
          "label": "Twice the rise plus the going (NCC Table 11.2.2a)",
          "value": 24.015748031496063,
          "unit": "in"
        },
        {
          "label": "Total run of the flight",
          "value": 11.48293963254593,
          "unit": "ft"
        },
        {
          "label": "Floor opening for the headroom",
          "value": 10.626275882181393,
          "unit": "ft"
        }
      ],
      "basis": "cited",
      "sourceIndex": 3
    },
    {
      "name": "2.6 m rise at a 190 mm target and a 260 mm run, Canadian NBC private stair",
      "inputs": {
        "totalRise": 2.6,
        "targetRiser": 0.19,
        "actualTreadDepth": 0.26,
        "buildingCode": "ca"
      },
      "expected": 14,
      "toleranceDecimalPlaces": 0,
      "unit": "risers",
      "confidence": "high",
      "steps": [
        {
          "label": "Actual riser height",
          "value": 7.311586051743532,
          "unit": "in"
        },
        {
          "label": "Number of treads (steps)",
          "value": 13,
          "unit": "treads"
        },
        {
          "label": "Recommended tread depth (comfort formula)",
          "value": 10.376827896512935,
          "unit": "in"
        },
        {
          "label": "Code max riser height (Canadian National Building Code)",
          "value": 7.874015748031496,
          "unit": "in"
        },
        {
          "label": "Code min run (Canadian National Building Code)",
          "value": 10.039370078740157,
          "unit": "in"
        },
        {
          "label": "Total run of the flight",
          "value": 11.089238845144356,
          "unit": "ft"
        },
        {
          "label": "Floor opening for the headroom",
          "value": 10.711286089238843,
          "unit": "ft"
        }
      ],
      "basis": "cited",
      "sourceIndex": 4
    },
    {
      "name": "2.8 m rise, 18.5 cm target, 26 cm tread, IRC, with 2.032 m headroom under a 300 mm floor",
      "inputs": {
        "totalRise": 2.8,
        "targetRiser": 0.185,
        "actualTreadDepth": 0.26,
        "buildingCode": "irc",
        "headroom": 2.032,
        "upperFloorDepth": 0.3
      },
      "expected": 15,
      "toleranceDecimalPlaces": 0,
      "unit": "risers",
      "confidence": "high",
      "steps": [
        {
          "label": "Actual riser height",
          "value": 7.349081364829394,
          "unit": "in"
        },
        {
          "label": "Number of treads (steps)",
          "value": 14,
          "unit": "treads"
        },
        {
          "label": "Recommended tread depth (comfort formula)",
          "value": 10.301837270341212,
          "unit": "in"
        },
        {
          "label": "Code max riser height (US IRC 2024)",
          "value": 7.75,
          "unit": "in"
        },
        {
          "label": "Code min tread depth (US IRC 2024)",
          "value": 10,
          "unit": "in"
        },
        {
          "label": "Total run of the flight",
          "value": 11.942257217847768,
          "unit": "ft"
        },
        {
          "label": "Floor opening for the headroom",
          "value": 10.656636670416198,
          "unit": "ft"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    }
  ],
  "usedByAssemblies": [
    {
      "id": "staircase-replacement",
      "name": "Staircase replacement"
    }
  ]
}