  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "stack-effect-pressure-calculator",
  "category": "plumbing-hvac",
  "title": "Stack Effect Pressure Calculator",
  "description": "Stack effect pressure across an opening from its height off the neutral plane and the indoor-outdoor temperature difference, and the air speed it drives.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/stack-effect-pressure-calculator.json",
  "inputCount": 5,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-09-22",
  "citation": {
    "author": "Craft Quantities",
    "title": "Stack Effect Pressure Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-22",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Stack Effect Pressure Calculator. Version 1.0.0. Sources checked 2026-09-22. https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/",
      "apa": "Craft Quantities. (2026). Stack Effect Pressure Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/",
      "harvard": "Craft Quantities (2026) Stack Effect Pressure Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-stack-effect-pressure-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Stack Effect Pressure Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/stack-effect-pressure-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "height",
      "label": "Height of the Opening From the Neutral Pressure Plane",
      "type": "number",
      "dimension": "length",
      "defaultValue": 6,
      "min": 0,
      "max": 500,
      "step": 0.1,
      "help": "How far the opening is below (or above) the level where inside and outside pressures are equal."
    },
    {
      "id": "position",
      "label": "Where the Opening Is",
      "type": "select",
      "defaultValue": "below",
      "options": [
        {
          "value": "below",
          "label": "Below the neutral plane — a door, a low vent"
        },
        {
          "value": "above",
          "label": "Above the neutral plane — a roof light, a high vent"
        }
      ],
      "help": "Sets the direction the air moves; the size of the pressure depends only on the height."
    },
    {
      "id": "insideTemp",
      "label": "Inside Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 18,
      "min": -20,
      "max": 50,
      "step": 0.5,
      "help": "The air temperature inside the building."
    },
    {
      "id": "outsideTemp",
      "label": "Outside Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -2,
      "min": -40,
      "max": 50,
      "step": 0.5,
      "help": "The outdoor air temperature."
    },
    {
      "id": "dischargeCoefficient",
      "label": "Discharge Coefficient of the Opening",
      "type": "number",
      "defaultValue": 0.65,
      "min": 0.3,
      "max": 1,
      "step": 0.01,
      "help": "How much of the ideal flow a real opening passes — about 0.65 for a large opening."
    }
  ],
  "sources": [
    {
      "label": "ASHRAE Handbook—Fundamentals, Chapter 16, Ventilation and Infiltration: stack pressure Δp = ρo × g × (H_NPL − H) × (Ti − To) ÷ Ti, temperatures absolute; flow through a large opening with a discharge coefficient of about 0.65"
    },
    {
      "label": "Outdoor air density from the ideal gas law: ρ = 101,325 Pa ÷ (287.055 J/kg·K × T), dry air at standard pressure"
    }
  ],
  "testCases": [
    {
      "name": "The warehouse guide's 12 m shed: floor-level door 6 m below mid-height, 20 K across the wall",
      "inputs": {
        "height": 6,
        "position": "below",
        "insideTemp": 18,
        "outsideTemp": -2,
        "dischargeCoefficient": 0.65
      },
      "expected": 5.2617,
      "toleranceDecimalPlaces": 3,
      "unit": "Pa",
      "confidence": "medium",
      "steps": [
        {
          "label": "The same pressure in inches of water gauge (in. w.g.)",
          "value": 0.02112382814884849,
          "unit": "in. w.g."
        },
        {
          "label": "Outdoor air density",
          "value": 1.3017928674874784,
          "unit": "kg/m³"
        },
        {
          "label": "Air speed through the opening at this discharge coefficient",
          "value": 1.8480806423945377,
          "unit": "m/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "The same 20 K as 20 °C inside and 0 °C outside",
      "inputs": {
        "height": 6,
        "position": "below",
        "insideTemp": 20,
        "outsideTemp": 0,
        "dischargeCoefficient": 0.65
      },
      "expected": 5.1876,
      "toleranceDecimalPlaces": 3,
      "unit": "Pa",
      "confidence": "medium",
      "steps": [
        {
          "label": "The same pressure in inches of water gauge (in. w.g.)",
          "value": 0.020826098854410707,
          "unit": "in. w.g."
        },
        {
          "label": "Outdoor air density",
          "value": 1.2922611606049048,
          "unit": "kg/m³"
        },
        {
          "label": "Air speed through the opening at this discharge coefficient",
          "value": 1.8417656379649583,
          "unit": "m/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A tall building: 30 m from the neutral plane, 21 °C inside, −10 °C outside",
      "inputs": {
        "height": 30,
        "position": "below",
        "insideTemp": 21,
        "outsideTemp": -10,
        "dischargeCoefficient": 0.65
      },
      "expected": 41.5894,
      "toleranceDecimalPlaces": 3,
      "unit": "Pa",
      "confidence": "medium",
      "steps": [
        {
          "label": "The same pressure in inches of water gauge (in. w.g.)",
          "value": 0.16696617738667355,
          "unit": "in. w.g."
        },
        {
          "label": "Outdoor air density",
          "value": 1.3413685579298111,
          "unit": "kg/m³"
        },
        {
          "label": "Air speed through the opening at this discharge coefficient",
          "value": 5.118535741167126,
          "unit": "m/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A high vent 4 m above the neutral plane, 20 °C inside and 0 °C outside — the same pressure, pushing out",
      "inputs": {
        "height": 4,
        "position": "above",
        "insideTemp": 20,
        "outsideTemp": 0,
        "dischargeCoefficient": 0.65
      },
      "expected": 3.4584,
      "toleranceDecimalPlaces": 3,
      "unit": "Pa",
      "confidence": "medium",
      "steps": [
        {
          "label": "The same pressure in inches of water gauge (in. w.g.)",
          "value": 0.01388406590294047,
          "unit": "in. w.g."
        },
        {
          "label": "Outdoor air density",
          "value": 1.2922611606049048,
          "unit": "kg/m³"
        },
        {
          "label": "Air speed through the opening at this discharge coefficient",
          "value": 1.5037953462685605,
          "unit": "m/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}