  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "spread-footing-sizing-calculator",
  "category": "materials-quantities",
  "title": "Isolated Spread Footing Sizing Calculator",
  "description": "Size a square isolated column footing from the column load and the site's allowable soil bearing pressure.",
  "url": "https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/spread-footing-sizing-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/spread-footing-sizing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Isolated Spread Footing Sizing Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Isolated Spread Footing Sizing Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/",
      "apa": "Craft Quantities. (2026). Isolated Spread Footing Sizing Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/",
      "harvard": "Craft Quantities (2026) Isolated Spread Footing Sizing Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-spread-footing-sizing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Isolated Spread Footing Sizing Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "columnLoad",
      "label": "Column Load",
      "type": "number",
      "dimension": "force",
      "defaultValue": 400000,
      "min": 10000,
      "max": 20000000,
      "step": 10,
      "help": "The total axial load the column transfers to the footing."
    },
    {
      "id": "allowableBearingPressure",
      "label": "Allowable Soil Bearing Pressure",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 150000,
      "min": 50000,
      "max": 1000000,
      "step": 10000,
      "help": "The soil's allowable bearing capacity, from a geotechnical report."
    }
  ],
  "sources": [
    {
      "label": "Standard preliminary footing sizing: required footing area = column load / allowable soil bearing pressure; assumed square, so side length = sqrt(area)"
    }
  ],
  "testCases": [
    {
      "name": "400kN load, 150kPa allowable",
      "inputs": {
        "columnLoad": 400000,
        "allowableBearingPressure": 150000
      },
      "expected": 1.633,
      "toleranceDecimalPlaces": 1,
      "unit": "m (square footing side)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required footing area",
          "value": 2.6666666666666665,
          "unit": "m²"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "600kN load, 200kPa allowable",
      "inputs": {
        "columnLoad": 600000,
        "allowableBearingPressure": 200000
      },
      "expected": 1.732,
      "toleranceDecimalPlaces": 1,
      "unit": "m (square footing side)",
      "confidence": "medium",
      "steps": [
        {
          "label": "Required footing area",
          "value": 3,
          "unit": "m²"
        }
      ],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}