{
  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "smoke-alarm-fit-out-calculator",
  "category": "electrical",
  "title": "Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries)",
  "description": "From a count of smoke alarms: the alarms, their mounting bases, interconnect cable on your own runs, and the batteries.",
  "url": "https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/smoke-alarm-fit-out-calculator.json",
  "inputCount": 5,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries)",
    "version": "1.0.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries). Version 1.0.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/",
      "apa": "Craft Quantities. (2026). Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/",
      "harvard": "Craft Quantities (2026) Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries) (Version 1.0.0). Available at: https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-smoke-alarm-fit-out-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Smoke Alarm Fit-Out Calculator (Alarms, Mounting Bases, Interconnect Cable and Batteries)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/smoke-alarm-fit-out-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "alarmCount",
      "label": "Number of Smoke Alarms",
      "type": "number",
      "defaultValue": 5,
      "min": 1,
      "max": 200,
      "step": 1,
      "help": "The alarm symbols on the drawing, or the number the placement rules give you."
    },
    {
      "id": "powerType",
      "label": "How They Are Powered",
      "type": "select",
      "defaultValue": "mains-replaceable",
      "options": [
        {
          "value": "mains-replaceable",
          "label": "Mains, replaceable backup battery"
        },
        {
          "value": "mains-sealed",
          "label": "Mains, sealed long-life battery"
        },
        {
          "value": "battery-replaceable",
          "label": "Battery only, replaceable cells"
        },
        {
          "value": "battery-sealed",
          "label": "Battery only, sealed 10-year cell"
        }
      ],
      "help": "Wired alarms need a base and cable; battery-only ones need neither."
    },
    {
      "id": "runPerAlarm",
      "label": "Cable Run to Each Alarm",
      "type": "number",
      "dimension": "length",
      "defaultValue": 4.5,
      "min": 0,
      "max": 60,
      "step": 0.1,
      "help": "Your measured route from the previous alarm, or the supply for the first, through ceiling and walls."
    },
    {
      "id": "batteriesPerAlarm",
      "label": "Batteries per Alarm",
      "type": "number",
      "defaultValue": 1,
      "min": 0,
      "max": 6,
      "step": 1,
      "help": "Cells each alarm takes, from its box: often one 9 V, sometimes two or three AA."
    },
    {
      "id": "allowancePercent",
      "label": "Cable Allowance (%)",
      "type": "number",
      "defaultValue": 10,
      "min": 0,
      "max": 50,
      "step": 1,
      "help": "Extra over the measured runs, for tails at each base and the route round obstacles."
    }
  ],
  "sources": [
    {
      "label": "International Residential Code (2021), R314.4 and R314.6: where more than one smoke alarm is required in a dwelling unit they are interconnected so that one sounding sounds them all, and their primary power is from the building wiring with a battery backup (physical or wireless interconnection is allowed where the code says so)",
      "url": "https://codes.iccsafe.org/content/IRC2021P2/chapter-3-building-planning#IRC2021P2_Pt03_Ch03_SecR314"
    },
    {
      "label": "BS 5839-6:2019+A1:2020, Fire detection and fire alarm systems for buildings, Part 6: Grade D1 is mains-powered alarms with a tamper-proof standby supply of a long-life battery, Grade D2 mains-powered alarms with a user-replaceable standby battery, and Grade F battery-powered alarms",
      "url": "https://knowledge.bsigroup.com/products/fire-detection-and-fire-alarm-systems-for-buildings-code-of-practice-for-the-design-installation-commissioning-and-maintenance-of-fire-detection-and-fire-alarm-systems-in-domestic-premises"
    }
  ],
  "testCases": [
    {
      "name": "5 wired alarms with replaceable backup: 5 alarms (4.5 m runs, 10%: 24.75 m of cable, 5 batteries)",
      "inputs": {
        "alarmCount": 5,
        "powerType": "mains-replaceable",
        "runPerAlarm": 4.5,
        "batteriesPerAlarm": 1,
        "allowancePercent": 10
      },
      "expected": 5,
      "toleranceDecimalPlaces": 0,
      "unit": "alarms",
      "confidence": "medium",
      "steps": [
        {
          "label": "Mounting bases",
          "value": 5,
          "unit": "bases"
        },
        {
          "label": "Interconnect cable",
          "value": 24.750000000000004,
          "unit": "m"
        },
        {
          "label": "Interconnect cable before the allowance",
          "value": 22.5,
          "unit": "m"
        },
        {
          "label": "Batteries to fit",
          "value": 5,
          "unit": "batteries"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "4 radio-linked battery alarms, two AA each: 4 alarms, no bases or cable, 8 batteries",
      "inputs": {
        "alarmCount": 4,
        "powerType": "battery-replaceable",
        "runPerAlarm": 6,
        "batteriesPerAlarm": 2,
        "allowancePercent": 10
      },
      "expected": 4,
      "toleranceDecimalPlaces": 0,
      "unit": "alarms",
      "confidence": "medium",
      "steps": [
        {
          "label": "Mounting bases",
          "value": 0,
          "unit": "bases"
        },
        {
          "label": "Interconnect cable",
          "value": 0,
          "unit": "m"
        },
        {
          "label": "Interconnect cable before the allowance",
          "value": 0,
          "unit": "m"
        },
        {
          "label": "Batteries to fit",
          "value": 8,
          "unit": "batteries"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "3 wired alarms with a sealed long-life cell (UK Grade D1): 3 alarms (3 bases, 5 m runs: 15 m of cable, no loose batteries)",
      "inputs": {
        "alarmCount": 3,
        "powerType": "mains-sealed",
        "runPerAlarm": 5,
        "batteriesPerAlarm": 1,
        "allowancePercent": 0
      },
      "expected": 3,
      "toleranceDecimalPlaces": 0,
      "unit": "alarms",
      "confidence": "medium",
      "steps": [
        {
          "label": "Mounting bases",
          "value": 3,
          "unit": "bases"
        },
        {
          "label": "Interconnect cable",
          "value": 15,
          "unit": "m"
        },
        {
          "label": "Interconnect cable before the allowance",
          "value": 15,
          "unit": "m"
        },
        {
          "label": "Batteries to fit",
          "value": 0,
          "unit": "batteries"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "6 battery-only sealed 10-year alarms: 6 alarms (no bases, no cable, no loose batteries)",
      "inputs": {
        "alarmCount": 6,
        "powerType": "battery-sealed",
        "runPerAlarm": 4.5,
        "batteriesPerAlarm": 1,
        "allowancePercent": 10
      },
      "expected": 6,
      "toleranceDecimalPlaces": 0,
      "unit": "alarms",
      "confidence": "medium",
      "steps": [
        {
          "label": "Mounting bases",
          "value": 0,
          "unit": "bases"
        },
        {
          "label": "Interconnect cable",
          "value": 0,
          "unit": "m"
        },
        {
          "label": "Interconnect cable before the allowance",
          "value": 0,
          "unit": "m"
        },
        {
          "label": "Batteries to fit",
          "value": 0,
          "unit": "batteries"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    }
  ]
}
