  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "single-phase-motor-full-load-current-calculator",
  "category": "electrical",
  "title": "Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW)",
  "description": "The running current a single-phase motor draws at full load, from its rating in hp or kW, the voltage, and its efficiency and power factor.",
  "url": "https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/single-phase-motor-full-load-current-calculator.json",
  "inputCount": 6,
  "testCaseCount": 12,
  "sourceCount": 5,
  "lastVerified": "2026-10-05",
  "citation": {
    "author": "Craft Quantities",
    "title": "Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW)",
    "version": "1.0.0",
    "sourcesChecked": "2026-10-05",
    "url": "https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW). Version 1.0.0. Sources checked 2026-10-05. https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/",
      "apa": "Craft Quantities. (2026). Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/",
      "harvard": "Craft Quantities (2026) Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW) (Version 1.0.0). Available at: https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-single-phase-motor-full-load-current-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Single-Phase Motor Full-Load Current Calculator (Amps from hp or kW)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/single-phase-motor-full-load-current-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "rating",
      "label": "Motor rating",
      "type": "number",
      "defaultValue": 0.75,
      "min": 0.05,
      "max": 20,
      "step": 0.01,
      "help": "The rated output on the nameplate — the shaft power, in the unit chosen below."
    },
    {
      "id": "ratingUnit",
      "label": "Rated in",
      "type": "select",
      "defaultValue": "hp",
      "options": [
        {
          "value": "hp",
          "label": "Horsepower (hp)"
        },
        {
          "value": "kw",
          "label": "Kilowatts (kW)"
        }
      ],
      "help": "The unit the nameplate states the rating in."
    },
    {
      "id": "voltage",
      "label": "Voltage the motor is connected for",
      "type": "select",
      "defaultValue": "230",
      "options": [
        {
          "value": "115",
          "label": "115 V (North American motor rating on a 120 V circuit)"
        },
        {
          "value": "120",
          "label": "120 V"
        },
        {
          "value": "200",
          "label": "200 V"
        },
        {
          "value": "208",
          "label": "208 V (two lines of a 208Y/120 V supply)"
        },
        {
          "value": "220",
          "label": "220 V"
        },
        {
          "value": "230",
          "label": "230 V (UK, European and Australian supply; North American motor rating on 240 V)"
        },
        {
          "value": "240",
          "label": "240 V"
        },
        {
          "value": "other",
          "label": "Another voltage — type it"
        }
      ],
      "help": "The rated voltage the motor runs at, as connected."
    },
    {
      "id": "customVoltage",
      "label": "Voltage you are working at (V)",
      "type": "number",
      "defaultValue": 220,
      "min": 12,
      "max": 600,
      "step": 1,
      "help": "The motor's rated voltage, when the list does not have it."
    },
    {
      "id": "efficiency",
      "label": "Efficiency at full load (%)",
      "type": "number",
      "defaultValue": 68.5,
      "min": 30,
      "max": 98,
      "step": 0.5,
      "help": "From the nameplate or the maker's data sheet; it opens on a real motor's figure — 68.5% in North America, 70% elsewhere."
    },
    {
      "id": "powerFactor",
      "label": "Power factor at full load",
      "type": "number",
      "defaultValue": 0.67,
      "min": 0.3,
      "max": 1,
      "step": 0.01,
      "help": "From the nameplate or the maker's data sheet; it opens on the same motor's figure — 0.67 in North America, 0.92 elsewhere."
    }
  ],
  "sources": [
    {
      "label": "Single-phase motor input current from rated output: I = P(out) ÷ (V × efficiency × power factor), the electrical input being the shaft output divided by the efficiency, and single-phase current that input divided by volts times power factor"
    },
    {
      "label": "WEG Rolled Steel General Purpose 1-phase Motors, performance data (AutomationDirect catalogue page tMTR-54): full-load amps, efficiency and power factor per motor — 3/4 hp 1,745 rpm .7518ES1B56C-S at 10.6/5.86-5.3 A (115/208-230 V), 68.5% and 0.67, the figures this page opens on; 1 hp 1,745 rpm 00118ES1B56C-S at 13.6/7.52-6.8 A, 71.0% and 0.68; 1 hp 3,500 rpm 00136ES1B56C-S at 10.1/5.64-5.06 A, 70.0% and 0.92",
      "url": "https://cdn.automationdirect.com/static/specs/weg1phmotor.pdf"
    },
    {
      "label": "Mechanical horsepower is 550 ft·lbf/s = 745.699872 W exactly"
    },
    {
      "label": "NFPA 70-1968, the National Electrical Code, Section 430-6(a) (reprinted with permission by the US Mine Safety and Health Administration): where a motor's current is used to size conductors, switches and branch-circuit protection, the code's full-load current tables are used instead of the nameplate current, and running overload protection is based on the nameplate. Its exceptions in the same section: 430-6(b), a sealed (hermetic-type) motor-compressor takes the full-load current marked on the nameplate of the equipment it is in, for the branch-circuit conductors, the controller and the protection; 430-6(c), a torque motor its nameplate locked-rotor current; and multispeed motors their own rules. Current editions number it 430.6(A)(1) and the single-phase table 430.248, which this page does not reproduce",
      "url": "https://arlweb.msha.gov/District/DIST_09/Electrical%20test%20materials/ART430.pdf"
    },
    {
      "label": "WEG W22 Single-Phase Electric Motor, Commercial Catalogue, European Market (Cod. 50069268, Rev. 00, 01/2017), page 5, Electrical Data, W22 Single-Phase CSR (starting and run capacitor), IV pole, 50 Hz: 0.75 kW (1 HP), frame 80, 1,435 rpm, efficiency 70.0% and power factor 0.92 at full load, 5.06 A at 230 V — the motor a UK, Australian or international reader opens on; II pole 0.75 kW, 2,915 rpm, 75.0% and 0.91, 4.78 A",
      "url": "https://static.weg.net/medias/downloadcenter/h52/h99/WEG-w22-single-phase-european-market-50069268-brochure-english-web.pdf"
    }
  ],
  "testCases": [
    {
      "name": "the opening motor: WEG's 3/4 hp at 230 V, 68.5% and 0.67, draws the 5.3 A its sheet lists",
      "inputs": {
        "rating": 0.75,
        "ratingUnit": "hp",
        "voltage": "230",
        "efficiency": 68.5,
        "powerFactor": 0.67
      },
      "expected": 5.298246,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.5592749036867027,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 559.2749036867027,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 0.8164597134112448,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.2185965871809623,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "the same motor connected for 115 V draws 10.6 A, twice the 230 V figure",
      "inputs": {
        "rating": 0.75,
        "ratingUnit": "hp",
        "voltage": "115",
        "efficiency": 68.5,
        "powerFactor": 0.67
      },
      "expected": 10.596492,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.5592749036867027,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 559.2749036867027,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 0.8164597134112448,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.2185965871809623,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 115,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "WEG's 1 hp 3,500 rpm motor at 230 V, 70% and 0.92: 5.04 A against the 5.06 A listed",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "230",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 5.03443,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "a kW reader's opening: WEG's 0.75 kW four-pole W22 at 230 V, 70% and 0.92, draws the 5.06 A its catalogue lists",
      "inputs": {
        "rating": 0.75,
        "ratingUnit": "kw",
        "voltage": "230",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 5.063462,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.75,
          "unit": "kW"
        },
        {
          "label": "Rated output in horsepower",
          "value": 1.005766567196271,
          "unit": "hp"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0714285714285716,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1645962732919255,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 4
    },
    {
      "name": "WEG's 0.75 kW two-pole W22 at 230 V, 75% and 0.91: 4.78 A, as listed",
      "inputs": {
        "rating": 0.75,
        "ratingUnit": "kw",
        "voltage": "230",
        "efficiency": 75,
        "powerFactor": 0.91
      },
      "expected": 4.777831,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.75,
          "unit": "kW"
        },
        {
          "label": "Rated output in horsepower",
          "value": 1.005766567196271,
          "unit": "hp"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.098901098901099,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 4
    },
    {
      "name": "a typed 220 V: 1.5 kW at 80% and 0.95 draws 8.97 A",
      "inputs": {
        "rating": 1.5,
        "ratingUnit": "kw",
        "voltage": "other",
        "customVoltage": 220,
        "efficiency": 80,
        "powerFactor": 0.95
      },
      "expected": 8.97129,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 1.5,
          "unit": "kW"
        },
        {
          "label": "Rated output in horsepower",
          "value": 2.011533134392542,
          "unit": "hp"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.875,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.9736842105263157,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 220,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "power factor 1 and 100% efficiency reduce to watts over volts: 2.3 kW at 230 V is 10 A",
      "inputs": {
        "rating": 2.3,
        "ratingUnit": "kw",
        "voltage": "230",
        "efficiency": 100,
        "powerFactor": 1
      },
      "expected": 10,
      "toleranceDecimalPlaces": 6,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 2.3,
          "unit": "kW"
        },
        {
          "label": "Rated output in horsepower",
          "value": 3.084350806068564,
          "unit": "hp"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 2.3,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 2.3,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 230,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "1 hp at 70% and 0.92 on 120 V draws 9.65 A",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "120",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 9.649325,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 120,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "1 hp at 70% and 0.92 on 200 V draws 5.79 A",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "200",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 5.789595,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 200,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "1 hp at 70% and 0.92 on 208 V draws 5.57 A",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "208",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 5.566919,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 208,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "1 hp at 70% and 0.92 on 220 V draws 5.26 A",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "220",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 5.263268,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 220,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "1 hp at 70% and 0.92 on 240 V draws 4.82 A",
      "inputs": {
        "rating": 1,
        "ratingUnit": "hp",
        "voltage": "240",
        "efficiency": 70,
        "powerFactor": 0.92
      },
      "expected": 4.824663,
      "toleranceDecimalPlaces": 4,
      "unit": "A",
      "confidence": "medium",
      "steps": [
        {
          "label": "Rated output at the shaft",
          "value": 0.7456998715822702,
          "unit": "kW"
        },
        {
          "label": "Rated output in watts",
          "value": 745.6998715822702,
          "unit": "W"
        },
        {
          "label": "Electrical input, output ÷ efficiency",
          "value": 1.0652855308318145,
          "unit": "kW"
        },
        {
          "label": "Apparent power drawn, volts × amps",
          "value": 1.1579190552519725,
          "unit": "kVA"
        },
        {
          "label": "Voltage used",
          "value": 240,
          "unit": "V"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}