  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "room-heat-loss-calculator",
  "category": "plumbing-hvac",
  "title": "Room Heat Loss and Radiator Size Calculator (Watts and BTU)",
  "description": "A room's design heat loss in watts and BTU/h, element by element by BS EN 12831, and the radiator size that meets it at your flow and return temperatures.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/room-heat-loss-calculator.json",
  "inputCount": 28,
  "testCaseCount": 14,
  "sourceCount": 16,
  "lastVerified": "2026-10-05",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/plumbing-hvac/room-heat-loss-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Room Heat Loss and Radiator Size Calculator (Watts and BTU)",
    "version": "1.0.0",
    "sourcesChecked": "2026-10-05",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Room Heat Loss and Radiator Size Calculator (Watts and BTU). Version 1.0.0. Sources checked 2026-10-05. https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/",
      "apa": "Craft Quantities. (2026). Room Heat Loss and Radiator Size Calculator (Watts and BTU) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/",
      "harvard": "Craft Quantities (2026) Room Heat Loss and Radiator Size Calculator (Watts and BTU) (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-room-heat-loss-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Room Heat Loss and Radiator Size Calculator (Watts and BTU)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "roomTemp",
      "label": "Room Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 18,
      "min": 10,
      "max": 30,
      "step": 0.5,
      "help": "The air temperature the room is designed to hold on the coldest design day; the help gives each country's figures."
    },
    {
      "id": "outsideTemp",
      "label": "Outdoor Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -3,
      "min": -45,
      "max": 20,
      "step": 0.1,
      "help": "A design figure for the location from a published table, not the coldest night anyone remembers."
    },
    {
      "id": "roomLength",
      "label": "Room Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 4,
      "min": 0.5,
      "max": 30,
      "step": 0.01,
      "help": "Inside the room, plaster to plaster, along one side."
    },
    {
      "id": "roomWidth",
      "label": "Room Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3.5,
      "min": 0.5,
      "max": 30,
      "step": 0.01,
      "help": "Inside the room, across the other side."
    },
    {
      "id": "ceilingHeight",
      "label": "Ceiling Height",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.4,
      "min": 1.5,
      "max": 10,
      "step": 0.01,
      "help": "Floor to ceiling. It sets the room's volume and the height of its external walls."
    },
    {
      "id": "externalLongWalls",
      "label": "External Walls Along the Length (0, 1 or 2)",
      "type": "number",
      "defaultValue": 1,
      "min": 0,
      "max": 2,
      "step": 1,
      "help": "How many of the two walls as long as the Room Length have the open air on their far side."
    },
    {
      "id": "externalShortWalls",
      "label": "External Walls Along the Width (0, 1 or 2)",
      "type": "number",
      "defaultValue": 0,
      "min": 0,
      "max": 2,
      "step": 1,
      "help": "How many of the two walls as long as the Room Width face outside."
    },
    {
      "id": "wallU",
      "label": "External Wall U-Value",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 1.5,
      "min": 0.05,
      "max": 4,
      "step": 0.01,
      "help": "How readily heat passes through the wall: the lower the figure, the better insulated the wall."
    },
    {
      "id": "windowArea",
      "label": "Window Area (frames included)",
      "type": "number",
      "dimension": "area",
      "defaultValue": 2.5,
      "min": 0,
      "max": 100,
      "step": 0.01,
      "help": "All the glazing in the room's external walls, measured over the frames."
    },
    {
      "id": "windowU",
      "label": "Window U-Value (whole window)",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 2,
      "min": 0.3,
      "max": 6,
      "step": 0.01,
      "help": "The whole window's figure, frame included, from its certificate, its label or the defaults in the help."
    },
    {
      "id": "doorArea",
      "label": "External Door Area (0 if none)",
      "type": "number",
      "dimension": "area",
      "defaultValue": 0,
      "min": 0,
      "max": 20,
      "step": 0.01,
      "help": "A solid or part-glazed outside door; RdSAP takes a standard one as 1.85 m² (19.9 sq ft)."
    },
    {
      "id": "doorU",
      "label": "External Door U-Value",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 3,
      "min": 0.5,
      "max": 6,
      "step": 0.01,
      "help": "RdSAP's figure for an outside door in a house built before 2007 is 3.0 W/m²K (0.53 BTU/hr·ft²·°F)."
    },
    {
      "id": "ceilingAbove",
      "label": "What Is Above the Room",
      "type": "select",
      "defaultValue": "roof",
      "options": [
        {
          "value": "heated",
          "label": "Another heated room (no loss upward)"
        },
        {
          "value": "roof",
          "label": "A loft, a roof or the open air"
        }
      ],
      "help": "The ceiling loses heat only when the space above it is colder than the room."
    },
    {
      "id": "roofU",
      "label": "Ceiling or Roof U-Value",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 0.4,
      "min": 0.05,
      "max": 3,
      "step": 0.01,
      "help": "Under a loft, read it from the depth of insulation over the ceiling; the help lists RdSAP's figures."
    },
    {
      "id": "floorBelow",
      "label": "What Is Below the Room",
      "type": "select",
      "defaultValue": "heated",
      "options": [
        {
          "value": "heated",
          "label": "Another heated room (no loss downward)"
        },
        {
          "value": "ground",
          "label": "The ground: a solid or suspended ground floor"
        },
        {
          "value": "exposed",
          "label": "Outside air or an unheated space, such as a garage"
        }
      ],
      "help": "Decides how the floor loses heat, and which of the floor fields below appear."
    },
    {
      "id": "groundFloorType",
      "label": "Ground Floor Construction",
      "type": "select",
      "defaultValue": "solid",
      "options": [
        {
          "value": "solid",
          "label": "Solid: concrete laid on the ground"
        },
        {
          "value": "suspended",
          "label": "Suspended timber over a ventilated void"
        }
      ],
      "help": "A solid floor is worked against the year's average outdoor temperature, a suspended one against the design temperature."
    },
    {
      "id": "groundFloorArea",
      "label": "Ground Floor Area of the Whole House",
      "type": "number",
      "dimension": "area",
      "defaultValue": 45,
      "min": 5,
      "max": 2000,
      "step": 0.1,
      "help": "The whole ground floor inside the external walls, not just this room: the earth under a house takes heat from the floor as one piece."
    },
    {
      "id": "groundFloorPerimeter",
      "label": "Exposed Perimeter of the Ground Floor",
      "type": "number",
      "dimension": "length",
      "defaultValue": 21,
      "min": 1,
      "max": 500,
      "step": 0.1,
      "help": "The length of the whole ground floor's edge that meets an outside wall; walls shared with the next house are left out."
    },
    {
      "id": "groundWallThickness",
      "label": "External Wall Thickness at the Floor",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.25,
      "min": 0.05,
      "max": 1,
      "step": 0.005,
      "help": "Measured at a door or window reveal; RdSAP assumes 250 mm (9.8 in) for a cavity wall built before 1976."
    },
    {
      "id": "groundFloorInsulation",
      "label": "Insulation Across the Ground Floor (0 if none)",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0,
      "min": 0,
      "max": 0.4,
      "step": 0.005,
      "help": "Thickness of any insulation laid across the whole floor, above or below the slab or between the joists."
    },
    {
      "id": "annualMeanTemp",
      "label": "Annual Mean Outdoor Temperature (solid floors)",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 11.3,
      "min": -10,
      "max": 30,
      "step": 0.1,
      "help": "The year's average outdoor temperature where the house is; only a solid ground floor uses it."
    },
    {
      "id": "exposedFloorU",
      "label": "Exposed Floor U-Value",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 1.2,
      "min": 0.05,
      "max": 4,
      "step": 0.01,
      "help": "A floor over outside air, a garage or a passage; the help lists RdSAP's figures."
    },
    {
      "id": "bridgingAllowance",
      "label": "Thermal Bridging Allowance",
      "type": "number",
      "dimension": "uvalue",
      "defaultValue": 0.15,
      "min": 0,
      "max": 0.5,
      "step": 0.01,
      "help": "Added to every element's U-value for heat that leaks round lintels, junctions and frames; 0 if your U-values already allow for it."
    },
    {
      "id": "airChanges",
      "label": "Air Changes per Hour",
      "type": "number",
      "defaultValue": 0.5,
      "min": 0,
      "max": 10,
      "step": 0.1,
      "help": "How many times an hour outdoor air replaces the room's air; 0.5 is the design guide's minimum for a room people live in."
    },
    {
      "id": "ventDevice",
      "label": "Chimney, Flue or Fan in the Room",
      "type": "select",
      "defaultValue": "none",
      "options": [
        {
          "value": "none",
          "label": "None"
        },
        {
          "value": "open-chimney",
          "label": "Open chimney — 80 m³/h (47 CFM)"
        },
        {
          "value": "blocked-chimney",
          "label": "Chimney blocked off with a small vent — 20 m³/h (12 CFM)"
        },
        {
          "value": "stove-flue",
          "label": "Chimney or open flue to a closed stove — 10 m³/h (5.9 CFM)"
        },
        {
          "value": "solid-fuel-boiler-flue",
          "label": "Chimney or open flue to a solid-fuel boiler — 20 m³/h (12 CFM)"
        },
        {
          "value": "heater-flue",
          "label": "Chimney or flue to another heater — 35 m³/h (21 CFM)"
        },
        {
          "value": "small-open-flue",
          "label": "Open flue under 200 mm (7.9 in) across — 20 m³/h (12 CFM)"
        },
        {
          "value": "flueless-gas-fire",
          "label": "Flueless gas fire — 40 m³/h (24 CFM)"
        },
        {
          "value": "extract-fan",
          "label": "Intermittent extract fan — 10 m³/h (5.9 CFM)"
        },
        {
          "value": "passive-vent",
          "label": "Passive stack vent — 10 m³/h (5.9 CFM)"
        }
      ],
      "help": "Each adds a fixed flow of outdoor air from SAP 10.2's table; an open chimney alone takes more heat than all the walls of the room either unit system opens on."
    },
    {
      "id": "flowTemp",
      "label": "Radiator Flow Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 55,
      "min": 25,
      "max": 95,
      "step": 0.5,
      "help": "The water temperature going into the radiator on the design day."
    },
    {
      "id": "returnTemp",
      "label": "Radiator Return Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 45,
      "min": 20,
      "max": 90,
      "step": 0.5,
      "help": "The water temperature leaving the radiator; the drop from flow to return is set by how fast the water is pumped."
    },
    {
      "id": "radiatorExponent",
      "label": "Radiator Exponent (n)",
      "type": "number",
      "defaultValue": 1.3,
      "min": 1,
      "max": 1.6,
      "step": 0.01,
      "help": "How steeply the radiator's output falls as the water cools; the maker publishes it beside the ΔT50 output."
    }
  ],
  "sources": [
    {
      "label": "BS EN 12831-1:2017, Energy performance of buildings — Method for calculation of the design heat load: each heated space's transmission loss (U × A × temperature difference over every element facing a colder space) plus its ventilation loss, at the internal and external design temperatures"
    },
    {
      "label": "MCS MIS 3005-D, The Heat Pump Standard (Design), Issue 2.0 (2 December 2024), clause 5.5.1: (a) the heat load to BS EN 12831-1:2017 at internal temperatures not less than Table 1 and external temperatures from Table 2 column A (99%) or B (99.6%), with no uplift for intermittent heating where column B is used; (c) through a solid floor on the ground, the internal design temperature less the local annual average external air temperature; (d) through a suspended floor, the internal less the design external temperature. Table 1: living, dining and bedsitting rooms 21 °C; bedroom, hall and landing, kitchen and toilet 18 °C; bathroom 22 °C. Table 2, from CIBSE Guide A Table 2.5 (altitude, 99% and 99.6%): Belfast 68 m −1.5 and −3.2 °C, Birmingham 96 m −3.2 and −5.1, Cardiff 67 m −1.5 and −3.1, Edinburgh 35 m −3.2 and −5.4, Glasgow 5 m −3.5 and −5.9, London 25 m −1.7 and −3.0, Manchester 75 m −2.7 and −4.5, Plymouth 27 m −0.2 and −1.5",
      "url": "https://mcscertified.com/wp-content/uploads/2025/02/MIS-3005-D-Issue-2.0-Final-.pdf"
    },
    {
      "label": "MCS Heat Load Calculator documentation, Design Conditions: design room temperatures from the CIBSE Domestic Heating Design Guide (2026) Table 2-2 (age bands A to J and K onwards); design external air temperatures from CIBSE Guide A (2015) Table 2.5, lowered 0.6 °C for every whole 100 m the property stands above the reference location (its Glasgow figure is −5.6 °C, against MIS 3005-D Table 2's −5.9 °C); annual mean external temperatures from Met Office records 1981 to 2010, MGD 007 Table B1 (Thames Valley, Heathrow, 11.3 °C)",
      "url": "https://heatloadcalculator.mcscertified.com/docs/reference-sources/design-conditions"
    },
    {
      "label": "MCS Heat Load Calculator documentation, Ventilation Rates: minimum room air change rates from the CIBSE Domestic Heating Design Guide (2026) Table 2-18 — 0.5 an hour for habitable rooms, 0 for an internal room or corridor, and zero for any room with no external envelope area; default air permeability 12 m³/h·m² at 50 Pa from BS EN 12831-1 Table B.6",
      "url": "https://heatloadcalculator.mcscertified.com/docs/reference-sources/ventilation-rates"
    },
    {
      "label": "MCS Heat Load Calculator documentation, Thermal Bridging: RdSAP 10 Table 21's factor added to all external building elements — 0.15 W/m²K for age bands A to I, 0.11 for J, 0.08 from K",
      "url": "https://heatloadcalculator.mcscertified.com/docs/reference-sources/thermal-bridging"
    },
    {
      "label": "BRE for the UK government, RdSAP10 Specification, version 4.0 (7 June 2026): Table 1 age bands; Table 3 wall thicknesses; Tables 6 and 13 wall U-values (England); Table 16 roof U-values by loft insulation depth and Table 18 when it is unknown; Table 20 exposed floors; Table 21 thermal bridging; Table 24 windows; Table 26 doors; §3.7, a door taken as 1.85 m²; §5.12, ground floors by BS EN ISO 13370, the U-value rounded to two decimal places, with clay soil (λ 1.5 W/m·K), Rsi 0.17, Rse 0.04 m²K/W, insulation at 0.035 W/m·K, and for a suspended floor a deck of 0.2 m²K/W, a 0.3 m void, 5 m/s wind, shielding 0.05, openings 0.003 m²/m and walls below the deck at 1.5 W/m²K",
      "url": "https://bregroup.com/documents/d/bre-group/rdsap-10-specification-2026-06-07"
    },
    {
      "label": "BRE for the UK government, SAP 10.2 (14-03-2025): worksheet line (38), ventilation heat loss = 0.33 × air change rate × dwelling volume; Table 2.1 ventilation rates — open chimney 80 m³/h, chimney or open flue to a closed stove 10, to a solid-fuel boiler 20, to another heater 35, chimney permanently blocked 20, open flue under 200 mm 20, intermittent extract fan 10, passive vent 10, flueless gas fire 40; an air permeability at 50 Pa divided by 20 as the infiltration rate",
      "url": "https://bregroup.com/documents/d/bre-group/sap-10-2-14-03-2025"
    },
    {
      "label": "BS EN 442-2, Radiators and convectors — Test methods and rating: output = K × ΔT^n, rated at 75 °C flow, 65 °C return and 20 °C air (ΔT50); the logarithmic mean excess where (return − room) ÷ (flow − room) is below 0.7"
    },
    {
      "label": "Purmo, product range GB catalogue (July 2024), Compact panel radiators: outputs at ΔT50 and ΔT30 tested to EN 442, and the n-coefficients from 1.2981 (Type 11, 300 mm high) to 1.3600 (Type 33, 900 mm) — a Type 22 750 × 1100 mm panel, n 1.3460, gives 2,261 W at ΔT50 and 1,137 W at ΔT30",
      "url": "https://www.purmo.com/docs/Purmo-Catalogue-GB2024.pdf"
    },
    {
      "label": "Approved Document L, Volume 1: Dwellings, 2021 edition incorporating 2023 amendments (England), paragraphs 5.8 and 5.10: heating sized on an appropriate heat loss calculation, and a new or fully replaced wet heating system sized to run at a maximum flow temperature of 55 °C or lower",
      "url": "https://assets.publishing.service.gov.uk/media/662a2e3e55e1582b6ca7e592/Approved_Document_L__Conservation_of_fuel_and_power__Volume_1_Dwellings__2021_edition_incorporating_2023_amendments.pdf"
    },
    {
      "label": "Approved Document L, Volume 1: Dwellings, 2026 edition (England), taking effect on 24 March 2027 for building work that is not higher-risk building work and on 24 September 2027 for higher-risk work: paragraph 4.9, heating designed on the BS EN 12831-1 heat loss calculation, and its note, a room-by-room calculation when a new heating system including the heating appliance and/or emitters is installed and a whole-dwelling one when only the appliance is replaced; paragraph 4.10, the 55 °C maximum flow temperature",
      "url": "https://assets.publishing.service.gov.uk/media/69c122a6cfa346b9d4704a55/ADL1_2026.pdf"
    },
    {
      "label": "ACCA Manual J (8th edition), Residential Load Calculation — the US room-by-room procedure, named here and not reproduced, which designs every room at one indoor temperature, commonly 70 °F"
    },
    {
      "label": "NIST Special Publication 811, Guide for the Use of the SI, Appendix B.8: one International Table Btu per hour is 0.2930711 W, the International Table Btu being exactly 1.055 055 852 62 kJ",
      "url": "https://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b8"
    },
    {
      "label": "MCS 021, Heat Emitter Guide for Domestic Heat Pumps, Issue 2.1 (May 2015): the room heat loss in watts times an oversize factor is the emitter output needed at a mean water-to-air temperature difference of 50 °C; heat pump designs graded by flow temperature band, from up to 35 °C to 61–65 °C, with more stars for lower emitter temperatures",
      "url": "https://mcscertified.com/wp-content/uploads/2025/06/MCS-021-Issue-2.1-Heat-Emitter-Guide.pdf"
    },
    {
      "label": "National Building Code of Canada 2020 (National Research Council), Division B: Article 9.33.3.1, heating able to hold at least 22 °C in all living spaces, 18 °C in unfinished basements and 15 °C in heated crawl spaces at the outside winter design temperature; Articles 9.33.3.2 and 1.1.3.1, the outdoor design conditions from the authority having jurisdiction or else Appendix C's January 2.5% values; Article 9.33.5.1, the capacity of a dwelling's heating appliances determined to CSA F280 with those design temperatures"
    },
    {
      "label": "Washington State Energy Code, Residential (WAC chapter 51-11R): WAC 51-11R-30200, Section R302.1, heating load calculations at an interior design temperature of at most 72 °F (22 °C); WAC 51-11R-60100, Table RC-1, Seattle (SeaTac airport) outdoor heating design temperature 24 °F; WAC 51-11R-30100, King County in climate zone 4C (marine); WAC 51-11R-40211, Table R402.1.2 for Climate Zone 5 and Marine 4, fenestration U-factor 0.30, ceiling U-factor 0.024, above-grade wall U-factor 0.056 and floor U-factor 0.029",
      "url": "https://app.leg.wa.gov/wac/default.aspx?cite=51-11R"
    }
  ],
  "testCases": [
    {
      "name": "The bedroom a metric page opens on: 4 × 3.5 × 2.4 m under a 100 mm loft, one external wall, 18 °C against −3 °C",
      "inputs": {
        "roomTemp": 18,
        "outsideTemp": -3,
        "roomLength": 4,
        "roomWidth": 3.5,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 1.5,
        "windowArea": 2.5,
        "windowU": 2,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "none",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 2173.582,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 839.4380238739769,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 385.1454868393194,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 551.7433020767925,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 397.2551774952906,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 637.014,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 2173.5819902853796,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 18,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 21,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 32,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 55.98013818589583,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 1.7863478590911186,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1137.9285951110699,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 3882.7735349053,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A corner living room on a solid ground floor with an outside door: the floor's U from RdSAP's BS EN ISO 13370, against the annual mean",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 5,
        "roomWidth": 4,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.7,
        "windowArea": 3,
        "windowU": 2,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "ground",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "none",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 3375.973,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 1165.9287960398265,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 528.1995248082094,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 477.22212880927754,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 556.0426005345337,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 648.5798816249641,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 989.3999999999999,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 3375.972931816811,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0.69,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 29,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 49.25568822553023,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.030222368269904,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 2008.7020111662428,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 6853.975760848217,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "The same room on a suspended timber floor: the void's U, against the design temperature",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 5,
        "roomWidth": 4,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.7,
        "windowArea": 3,
        "windowU": 2,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "ground",
        "groundFloorType": "suspended",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "none",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 4228.462,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 1165.9287960398265,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 528.1995248082094,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 477.22212880927754,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 1408.532066155225,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 648.5798816249641,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 1239.2399999999998,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 4228.462397437503,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0.71,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 29,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 49.25568822553023,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.030222368269904,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 2515.9327676547955,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 8584.718942665802,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 5
    },
    {
      "name": "The metric opening with a heated room above and a garage below: RdSAP's 1.20 exposed floor",
      "inputs": {
        "roomTemp": 18,
        "outsideTemp": -3,
        "roomLength": 4,
        "roomWidth": 3.5,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 1.5,
        "windowArea": 2.5,
        "windowU": 2,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "exposed",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "none",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 2976.118,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 839.4380238739769,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 385.1454868393194,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 1354.2790141884905,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 397.2551774952906,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 872.2139999999999,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 2976.117702397077,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 1.2,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 18,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 21,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 32,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 55.98013818589583,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 1.7863478590911186,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1558.0776115693009,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 5316.381486080198,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 5
    },
    {
      "name": "The metric opening as a study at 21 °C with an open chimney: SAP 10.2's 80 m³/h",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 4,
        "roomWidth": 3.5,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 1.5,
        "windowArea": 2.5,
        "windowU": 2,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "open-chimney",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 4646.027,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 959.3577415702593,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 440.1662706735079,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 630.5637738020486,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 2615.938855887355,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 1361.616,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 4646.026641933171,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 29,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 49.25568822553023,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.030222368269904,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 2764.3832601941936,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 9432.467212030631,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "A 2007-built en-suite bedroom at 21 °C, 270 mm loft, two outside walls, a blocked chimney, heat pump at 45/40",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 3.6,
        "roomWidth": 3.2,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.3,
        "windowArea": 2,
        "windowU": 1.4,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.16,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.08,
        "airChanges": 0.5,
        "ventDevice": "blocked-chimney",
        "flowTemp": 45,
        "returnTemp": 40,
        "radiatorExponent": 1.3
      },
      "expected": 1828.497,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 445.6202378598996,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 242.3985416174108,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 226.41334049453292,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 914.0652465034494,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 535.87968,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 1828.497366475293,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 21.5,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 33.38174169271837,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.9956495655771374,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1605.3077305936154,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 5477.53734154065,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "A small bathroom at 22 °C with a passive stack vent, where 55/45 water falls under EN 442's 0.7 ratio",
      "inputs": {
        "roomTemp": 22,
        "outsideTemp": -3,
        "roomLength": 2.5,
        "roomWidth": 2,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 1.5,
        "windowArea": 0.6,
        "windowU": 2.8,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "passive-vent",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 1596.029,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 760.0545487792549,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 150.98726726591255,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 234.5847372775478,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 450.4026955728918,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 467.75,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 1596.029248895607,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 22,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 25,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 27.699807011610744,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 46.40435714610588,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.1549700534617084,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1007.9872425067141,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 3439.3952358190163,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 7
    },
    {
      "name": "A Birmingham hall at 18 °C with a front door and an old open flue on an insulated solid floor, against the Midlands' annual mean",
      "inputs": {
        "roomTemp": 18,
        "outsideTemp": -5.1,
        "roomLength": 4.5,
        "roomWidth": 1.8,
        "ceilingHeight": 2.4,
        "externalLongWalls": 0,
        "externalShortWalls": 1,
        "wallU": 1.5,
        "windowArea": 0.4,
        "windowU": 2,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "ground",
        "groundFloorType": "solid",
        "groundFloorArea": 60,
        "groundFloorPerimeter": 32,
        "groundWallThickness": 0.3,
        "groundFloorInsulation": 0.025,
        "annualMeanTemp": 9.8,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "small-open-flue",
        "flowTemp": 70,
        "returnTemp": 50,
        "radiatorExponent": 1.3
      },
      "expected": 1707.61,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 269.2113211776121,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 67.7856056837202,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 459.3262989789297,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 138.24701283613936,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 773.0396584926215,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 500.45106,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 1707.6098971690226,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0.46,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 18,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 23.1,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 41.19398153827582,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 77.73612631070357,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 1.2864031788812056,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 643.781834458469,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 2196.6748000072394,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "A ground-floor WC at 18 °C with an extract fan, heated rooms above and below",
      "inputs": {
        "roomTemp": 18,
        "outsideTemp": -3,
        "roomLength": 1.6,
        "roomWidth": 0.9,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 1.5,
        "windowArea": 0.3,
        "windowU": 2,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "extract-fan",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 742.076,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 418.5367048611096,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 46.217458420718316,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 277.3219477181409,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 217.48104,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 742.0761109999689,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 18,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 21,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 32,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 55.98013818589583,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 1.7863478590911186,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 388.49679019690996,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 1325.6060721674578,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "A solid-brick utility room at 18 °C with single glazing, a back door and a solid-fuel boiler's flue",
      "inputs": {
        "roomTemp": 18,
        "outsideTemp": -3,
        "roomLength": 2.8,
        "roomWidth": 2.2,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 1.7,
        "windowArea": 0.8,
        "windowU": 4.8,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "ground",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "solid-fuel-boiler-flue",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 2706.784,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 1239.4519178796515,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 283.75369821092187,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 417.56936270811786,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 118.29376396526428,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 647.7151084494642,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 793.2800400000001,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 2706.78385121342,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0.69,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 18,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 21,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 32,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 55.98013818589583,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 1.7863478590911186,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1417.0741011137172,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 4835.257537637506,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 5
    },
    {
      "name": "A US room to Manual J's 70 °F against 10 °F outside, 16 × 12 × 8 ft, a gas heater's flue, water at 180/160 °F",
      "inputs": {
        "roomTemp": 21.11111111111111,
        "outsideTemp": -12.222222222222221,
        "roomLength": 4.8768,
        "roomWidth": 3.6576,
        "ceilingHeight": 2.4384,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.45,
        "windowArea": 2.787,
        "windowU": 1.7,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.17,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0,
        "airChanges": 0.35,
        "ventDevice": "heater-flue",
        "flowTemp": 82.22222222222223,
        "returnTemp": 71.11111111111111,
        "radiatorExponent": 1.3
      },
      "expected": 3691.297,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 922.4698099376791,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 538.8795281198999,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 344.8941837234304,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 1885.0530135294734,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 1081.812225926451,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 3691.296535310483,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21.11111111111111,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 33.33333333333333,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 55.55555555555556,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 114.67922193646555,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 0.871997545077537,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 943.3376052427311,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 3218.801516943959,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 11
    },
    {
      "name": "The corner living room with a closed wood stove's flue, over a heated room",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 5,
        "roomWidth": 4,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.7,
        "windowArea": 3,
        "windowU": 2,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "stove-flue",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 3090.172,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 1165.9287960398265,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 528.1995248082094,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 477.22212880927754,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 918.8214989686993,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 905.6399999999999,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 3090.1719486260126,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 29,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 49.25568822553023,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.030222368269904,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 1838.6505855999555,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 6273.736211900727,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "The corner room as a dining room with a flueless gas fire, on water at 50/30",
      "inputs": {
        "roomTemp": 21,
        "outsideTemp": -3,
        "roomLength": 5,
        "roomWidth": 4,
        "ceilingHeight": 2.4,
        "externalLongWalls": 1,
        "externalShortWalls": 1,
        "wallU": 0.7,
        "windowArea": 3,
        "windowU": 2,
        "doorArea": 1.85,
        "doorU": 3,
        "ceilingAbove": "heated",
        "roofU": 0.4,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0.15,
        "airChanges": 0.5,
        "ventDevice": "flueless-gas-fire",
        "flowTemp": 50,
        "returnTemp": 30,
        "radiatorExponent": 1.3
      },
      "expected": 3900.897,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 1165.9287960398265,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 528.1995248082094,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 477.22212880927754,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 1729.5463509999045,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 1143.2399999999998,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 3900.896800657217,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 24,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 17.092976136879923,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 24.77433390043313,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 4.036435465909809,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 4614.61448204673,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 15745.7181950269,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 6
    },
    {
      "name": "The room an imperial page opens on: 13 × 11.5 × 8 ft in Seattle at 70 °F against 24 °F, built to Washington's energy code",
      "inputs": {
        "roomTemp": 21.11111111111111,
        "outsideTemp": -4.444444444444445,
        "roomLength": 3.9624,
        "roomWidth": 3.5052,
        "ceilingHeight": 2.4384,
        "externalLongWalls": 1,
        "externalShortWalls": 0,
        "wallU": 0.31798274710235536,
        "windowArea": 2.50838208,
        "windowU": 1.7034790023340463,
        "doorArea": 0,
        "doorU": 3,
        "ceilingAbove": "roof",
        "roofU": 0.1362783201867237,
        "floorBelow": "heated",
        "groundFloorType": "solid",
        "groundFloorArea": 45,
        "groundFloorPerimeter": 21,
        "groundWallThickness": 0.25,
        "groundFloorInsulation": 0,
        "annualMeanTemp": 11.3,
        "exposedFloorU": 1.2,
        "bridgingAllowance": 0,
        "airChanges": 0.5,
        "ventDevice": "none",
        "flowTemp": 55,
        "returnTemp": 45,
        "radiatorExponent": 1.3
      },
      "expected": 1223.273,
      "toleranceDecimalPlaces": 2,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Lost through the external walls",
          "value": 198.35200000000154,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the windows",
          "value": 372.6000000000028,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the external door",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the ceiling or roof",
          "value": 165.04800000000125,
          "unit": "BTU/h"
        },
        {
          "label": "Lost through the floor",
          "value": 0,
          "unit": "BTU/h"
        },
        {
          "label": "Lost warming the air that comes in",
          "value": 487.2730456100067,
          "unit": "BTU/h"
        },
        {
          "label": "Room heat loss in watts (W)",
          "value": 358.5059405897572,
          "unit": "W"
        },
        {
          "label": "Room heat loss in BTU per hour (BTU/h)",
          "value": 1223.2730456100123,
          "unit": "BTU/h"
        },
        {
          "label": "Floor U-value used, before the bridging allowance",
          "value": 0,
          "unit": "W/m²K"
        },
        {
          "label": "Room design temperature",
          "value": 21.11111111111111,
          "unit": "°C"
        },
        {
          "label": "Indoor-to-outdoor design difference",
          "value": 25.555555555555557,
          "unit": "Δ°C"
        },
        {
          "label": "Water temperature above the room (EN 442 excess)",
          "value": 28.88888888888889,
          "unit": "Δ°C"
        },
        {
          "label": "Radiator output here, as a share of its ΔT50 rating",
          "value": 49.010494503256815,
          "unit": "%"
        },
        {
          "label": "Radiator rating needed, as a multiple of the room's heat loss",
          "value": 2.040379331274751,
          "unit": "×"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in watts (W)",
          "value": 731.4881113185544,
          "unit": "W"
        },
        {
          "label": "Radiator rating to look for at ΔT50, in BTU per hour (BTU/h)",
          "value": 2495.941038768185,
          "unit": "BTU/h"
        }
      ],
      "basis": "cited",
      "sourceIndex": 15
    }
  ]
}