  "title": "Ground-to-Roof Snow Load Calculator",
  "description": "Convert ground snow load to flat-roof design snow load per ASCE 7.",
  "url": "https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/roof-snow-load-calculator.json",
  "inputCount": 4,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-02",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/roof-snow-load-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Ground-to-Roof Snow Load Calculator",
    "version": "1.1.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Ground-to-Roof Snow Load Calculator. Version 1.1.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/",
      "apa": "Craft Quantities. (2026). Ground-to-Roof Snow Load Calculator (Version 1.1.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/",
      "harvard": "Craft Quantities (2026) Ground-to-Roof Snow Load Calculator (Version 1.1.1). Available at: https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-roof-snow-load-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Ground-to-Roof Snow Load Calculator},\n  version      = {1.1.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/roof-snow-load-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "groundSnowLoad",
      "label": "Ground Snow Load pg",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 1500,
      "min": 200,
      "max": 15000,
      "step": 100,
      "help": "The site's ground snow load, from your local building code's ground snow load map."
    },
    {
      "id": "exposureFactor",
      "label": "Exposure Factor Ce",
      "type": "number",
      "defaultValue": 1,
      "min": 0.7,
      "max": 1.3,
      "step": 0.05,
      "help": "Accounts for wind exposure and terrain, which affects how much snow accumulates on the roof versus blows off."
    },
    {
      "id": "thermalFactor",
      "label": "Thermal Factor Ct",
      "type": "number",
      "defaultValue": 1,
      "min": 0.85,
      "max": 1.3,
      "step": 0.05,
      "help": "Accounts for heat loss through the roof that can melt accumulated snow."
    },
    {
      "id": "importanceFactor",
      "label": "Importance Factor Is",
      "type": "number",
      "defaultValue": 1,
      "min": 0.8,
      "max": 1.2,
      "step": 0.05,
      "help": "Based on the building's risk category, per ASCE 7."
    }
  ],
  "sources": [
    {
      "label": "ASCE 7 flat-roof snow load: pf = 0.7 × Ce × Ct × Is × pg, where Ce is exposure factor, Ct is thermal factor, Is is importance factor, and pg is ground snow load"
    }
  ],
  "testCases": [
    {
      "name": "pg=1.5, Ce=Ct=Is=1.0",
      "inputs": {
        "groundSnowLoad": 1500,
        "exposureFactor": 1,
        "thermalFactor": 1,
        "importanceFactor": 1
      },
      "expected": 1.05,
      "toleranceDecimalPlaces": 1,
      "unit": "kN/m²",
      "confidence": "high",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "pg=2.0, Ce=0.9, Ct=1.1, Is=1.0",
      "inputs": {
        "groundSnowLoad": 2000,
        "exposureFactor": 0.9,
        "thermalFactor": 1.1,
        "importanceFactor": 1
      },
      "expected": 1.386,
      "toleranceDecimalPlaces": 1,
      "unit": "kN/m²",
      "confidence": "high",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}