  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "roof-scupper-sizing-calculator",
  "category": "materials-quantities",
  "title": "Roof Scupper/Secondary Emergency Drain Sizing Calculator",
  "description": "Calculate the required scupper or secondary drain opening area for a roof area, using a rainfall-intensity sizing factor.",
  "url": "https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/roof-scupper-sizing-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-06",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/roof-scupper-sizing-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Roof Scupper/Secondary Emergency Drain Sizing Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-06",
    "url": "https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Roof Scupper/Secondary Emergency Drain Sizing Calculator. Version 1.0.1. Sources checked 2026-09-06. https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/",
      "apa": "Craft Quantities. (2026). Roof Scupper/Secondary Emergency Drain Sizing Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/",
      "harvard": "Craft Quantities (2026) Roof Scupper/Secondary Emergency Drain Sizing Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-roof-scupper-sizing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Roof Scupper/Secondary Emergency Drain Sizing Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/roof-scupper-sizing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "roofArea",
      "label": "Tributary Roof Area",
      "type": "number",
      "dimension": "area",
      "defaultValue": 200,
      "min": 0.01,
      "max": 5000,
      "step": 10,
      "help": "The roof area draining to this scupper or secondary drain."
    },
    {
      "id": "sizingFactor",
      "label": "Sizing Factor (cm² of opening per m² of roof, per local rainfall intensity/code table)",
      "type": "number",
      "defaultValue": 2.5,
      "min": 1,
      "max": 6,
      "step": 0.1,
      "help": "The opening area required per unit of roof area, set by local design rainfall intensity and code drainage tables."
    }
  ],
  "sources": [
    {
      "label": "Required opening area = roof area × a sizing factor derived from the local design rainfall intensity, following the same tributary-area method used by plumbing code roof drainage sizing tables (e.g. IPC Appendix roof drain sizing)"
    }
  ],
  "testCases": [
    {
      "name": "200m² roof, 2.5 sizing factor",
      "inputs": {
        "roofArea": 200,
        "sizingFactor": 2.5
      },
      "expected": 500,
      "toleranceDecimalPlaces": 0,
      "unit": "cm²",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "300m² roof, 3.0 sizing factor",
      "inputs": {
        "roofArea": 300,
        "sizingFactor": 3
      },
      "expected": 900,
      "toleranceDecimalPlaces": 0,
      "unit": "cm²",
      "confidence": "medium",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}