  "title": "Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air)",
  "description": "The kitchen extract the 2021 IRC, NBC 2020 or England's rules ask of a range (cooker) hood, HVI's figure for the cooktop, and when make-up air is needed.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/range-hood-airflow-calculator.json",
  "inputCount": 5,
  "testCaseCount": 6,
  "sourceCount": 5,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air)",
    "version": "1.0.1",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air). Version 1.0.1. Sources checked 2026-10-31. https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/",
      "apa": "Craft Quantities. (2026). Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air) (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/",
      "harvard": "Craft Quantities (2026) Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air) (Version 1.0.1). Available at: https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-range-hood-airflow-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Range Hood and Cooker Hood Airflow Calculator (CFM, L/s and Make-Up Air)},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/range-hood-airflow-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "code",
      "label": "Code",
      "type": "select",
      "defaultValue": "irc",
      "options": [
        {
          "value": "irc",
          "label": "United States: 2021 IRC (M1503.6, M1505.4.4)"
        },
        {
          "value": "nbc",
          "label": "Canada: NBC 2020 (9.32.3.7, 9.32.3.8)"
        },
        {
          "value": "adf",
          "label": "England: Approved Documents F (2021) and J"
        }
      ],
      "help": "The code whose kitchen extract and make-up air rules the page restates."
    },
    {
      "id": "cooktopWidth",
      "label": "Cooktop or Range Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.6,
      "min": 0.2,
      "max": 3,
      "step": 0.01,
      "help": "The width of the cooking surface the hood serves, which sets the trade guide's airflow."
    },
    {
      "id": "hoodPosition",
      "label": "Hood Position",
      "type": "select",
      "defaultValue": "wall",
      "options": [
        {
          "value": "wall",
          "label": "Against a wall"
        },
        {
          "value": "island",
          "label": "Over an island"
        }
      ],
      "help": "A hood over an island has no wall behind it to steer the plume, so the guide asks more of it."
    },
    {
      "id": "hoodRating",
      "label": "Hood's Rated Airflow at Its Top Setting",
      "type": "number",
      "dimension": "airflow",
      "defaultValue": 277.77777777777777,
      "min": 1,
      "max": 2000,
      "step": 0.1,
      "help": "The most the hood is rated to move, from its label or data sheet; the codes judge what it is capable of, not the speed you use."
    },
    {
      "id": "appliance",
      "label": "Fuel-Burning Appliances in the Home",
      "type": "select",
      "defaultValue": "heating",
      "options": [
        {
          "value": "none",
          "label": "No natural-draft or open-flued appliance (all electric, or only direct-vent or room-sealed ones)"
        },
        {
          "value": "heating",
          "label": "A natural-draft (open-flued) furnace, boiler or water heater elsewhere in the home"
        },
        {
          "value": "kitchen",
          "label": "An open-flued gas appliance in the kitchen itself"
        }
      ],
      "help": "Whether a hood running hard could pull flue gases back down a natural-draft flue, which is what the make-up air rules guard against."
    }
  ],
  "sources": [
    {
      "label": "International Code Council, 2021 International Residential Code, as adopted without amendment in the Colorado Division of Fire Prevention and Control Residential Code 2021: M1503.6 makeup air for an exhaust system capable of more than 400 cfm (0.19 m³/s) where a fuel-burning appliance that is neither direct-vent nor mechanical-draft is inside the dwelling unit's air barrier, at a rate approximately equal to the exhaust rate, with the space-cooling exception; Table M1505.4.4, kitchens 100 cfm intermittent or 25 cfm continuous (its footnote a states the bathroom rate at 0.25 in. w.c., 62 Pa; the kitchen row names no static pressure); M1505.3, fans listed and labeled for their airflow to ANSI/AMCA 210-ANSI/ASHRAE 51. Ohio's Residential Code (Ohio Adm. Code 4101:8-15-01, effective 1 July 2019) and the 2024 IRC carry the same 1503.6 wording",
      "url": "https://up.codes/viewer/colorado/irc-2021/chapter/15/exhaust-systems"
    },
    {
      "label": "National Research Council of Canada, National Building Code of Canada 2020 (NBC 2020), Division B: 9.32.3.7.(1)–(3), a supplemental exhaust fan of not less than 50 L/s in each kitchen and its exceptions; 9.32.3.8, protection against depressurization: with a fuel-fired space- or water-heating appliance that is not direct- or mechanically vented, outdoor makeup air from a fan rated at not less than the exhausting device's capacity and not more than 10% above it, interlocked with it, tempered to at least 12 °C or delivered to an unoccupied area; exceptions for solid fuel only, a CAN/CGSB-51.71 depressurization test, and radon subfloor systems"
    },
    {
      "label": "HM Government, Approved Document F Volume 1: Dwellings (2021 edition, in force 15 June 2022): Table 1.1, intermittent extract of 30 l/s from a kitchen with a cooker hood extracting to the outside and 60 l/s without one; Table 1.2, a continuous high rate of 13 l/s; paragraph 1.21, a cooker hood 650 to 750 mm above the hob unless the maker specifies; paragraphs 0.17–0.18, fans and open-flued appliances under Approved Document J",
      "url": "https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/1045918/ADF1.pdf"
    },
    {
      "label": "HM Government, Approved Document J (2010 edition incorporating 2010, 2013 and 2022 amendments), 1.20: where a kitchen contains an open-flued gas appliance, the kitchen extract fan's rate should not exceed 20 litres/second (72 m³/hour); 40 l/s for an oil appliance with a pressure-jet burner and 20 l/s with a vaporising burner; no extract in the same room as a solid fuel appliance; 1.21, a spillage test under the greatest depressurization",
      "url": "https://assets.publishing.service.gov.uk/media/6336e58be90e0772dc9651a2/ADJ_2022.pdf"
    },
    {
      "label": "Home Ventilating Institute, 'How Much Ventilation Do I Need?' (Home Ventilation Guide): range hoods against a wall 100 CFM recommended and 40 CFM minimum per linear foot of range; over an island 150 and 50; worked at 2.5 ft, 3 ft and 4 ft",
      "url": "https://www.hvi.org/resources/publications/home-ventilation-guide-articles/how-much-ventilation-do-i-need/"
    }
  ],
  "testCases": [
    {
      "name": "IRC: a 600 CFM hood with a natural-draft water heater inside the air barrier needs about 600 CFM (283.17 L/s) of make-up air",
      "inputs": {
        "code": "irc",
        "cooktopWidth": 0.762,
        "hoodPosition": "wall",
        "hoodRating": 283.16846580000004,
        "appliance": "heating"
      },
      "expected": 283.1685,
      "toleranceDecimalPlaces": 3,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 283.16846580000004,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 117.9868608,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 188.77897728,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "IRC: the same hood in an all-electric home needs none under the 2021 text",
      "inputs": {
        "code": "irc",
        "cooktopWidth": 0.762,
        "hoodPosition": "wall",
        "hoodRating": 283.16846580000004,
        "appliance": "none"
      },
      "expected": 0,
      "toleranceDecimalPlaces": 6,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 283.16846580000004,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 117.9868608,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 188.77897728,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "IRC: a hood rated exactly 400 CFM is not over the line",
      "inputs": {
        "code": "irc",
        "cooktopWidth": 0.762,
        "hoodPosition": "wall",
        "hoodRating": 188.7789772,
        "appliance": "heating"
      },
      "expected": 0,
      "toleranceDecimalPlaces": 6,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 188.7789772,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 117.9868608,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 188.77897728,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "NBC: a 600 m³/h hood with naturally vented heating needs a make-up air fan of at least its 166.67 L/s",
      "inputs": {
        "code": "nbc",
        "cooktopWidth": 0.6,
        "hoodPosition": "wall",
        "hoodRating": 166.66666666666666,
        "appliance": "heating"
      },
      "expected": 166.6667,
      "toleranceDecimalPlaces": 3,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 166.66666666666666,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 50,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 92.90303999999999,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 37.161215999999996,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 0,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "IRC: an island hood rated 600 CFM over a 36 in range, an open-flued appliance in the kitchen: make-up air about 600 CFM",
      "inputs": {
        "code": "irc",
        "cooktopWidth": 0.9144,
        "hoodPosition": "island",
        "hoodRating": 283.16846580000004,
        "appliance": "kitchen"
      },
      "expected": 283.1685,
      "toleranceDecimalPlaces": 3,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 283.16846580000004,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 47.19474432,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 212.37634943999998,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 70.79211648,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 188.77897728,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "England: no make-up air figure, whatever the hood",
      "inputs": {
        "code": "adf",
        "cooktopWidth": 0.6,
        "hoodPosition": "wall",
        "hoodRating": 166.66666666666666,
        "appliance": "kitchen"
      },
      "expected": 0,
      "toleranceDecimalPlaces": 6,
      "unit": "L/s",
      "confidence": "medium",
      "steps": [
        {
          "label": "Hood airflow as rated",
          "value": 166.66666666666666,
          "unit": "L/s"
        },
        {
          "label": "Code minimum for a kitchen extract",
          "value": 30,
          "unit": "L/s"
        },
        {
          "label": "HVI's recommended airflow for this cooktop",
          "value": 92.90303999999999,
          "unit": "L/s"
        },
        {
          "label": "HVI's minimum for this cooktop",
          "value": 37.161215999999996,
          "unit": "L/s"
        },
        {
          "label": "Airflow at which the code's combustion-air rule starts",
          "value": 20,
          "unit": "L/s"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    }
  ]
}