  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "radiator-output-delta-t-calculator",
  "category": "plumbing-hvac",
  "title": "Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator",
  "description": "What a radiator gives at the water temperatures a heat pump or condensing boiler runs at, and the catalogue rating to buy so it still heats the room.",
  "url": "https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/radiator-output-delta-t-calculator.json",
  "inputCount": 7,
  "testCaseCount": 5,
  "sourceCount": 3,
  "lastVerified": "2026-09-21",
  "citation": {
    "author": "Craft Quantities",
    "title": "Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-21",
    "url": "https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator. Version 1.0.0. Sources checked 2026-09-21. https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/",
      "apa": "Craft Quantities. (2026). Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/",
      "harvard": "Craft Quantities (2026) Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/",
      "bibtex": "@misc{craftquantities-calculators-plumbing-hvac-radiator-output-delta-t-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Radiator Output at Lower Flow Temperature (ΔT Correction) Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/plumbing-hvac/radiator-output-delta-t-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "roomHeatLoss",
      "label": "Room Heat Loss the Radiator Must Meet",
      "type": "number",
      "dimension": "thermal",
      "defaultValue": 1000,
      "min": 50,
      "max": 30000,
      "step": 10,
      "help": "The room's design heat loss, from a room-by-room heat loss calculation."
    },
    {
      "id": "flowTemp",
      "label": "Flow Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 45,
      "min": 25,
      "max": 95,
      "step": 0.5,
      "help": "The water temperature entering the radiator at design conditions."
    },
    {
      "id": "returnTemp",
      "label": "Return Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 40,
      "min": 20,
      "max": 90,
      "step": 0.5,
      "help": "The water temperature leaving the radiator, back to the heat source."
    },
    {
      "id": "roomTemp",
      "label": "Room Design Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 21,
      "min": 5,
      "max": 30,
      "step": 0.5,
      "help": "The air temperature the room is designed to hold."
    },
    {
      "id": "exponent",
      "label": "Radiator Exponent (n)",
      "type": "number",
      "defaultValue": 1.3,
      "min": 1,
      "max": 1.6,
      "step": 0.01,
      "help": "How steeply output falls with temperature — from the radiator's data sheet."
    },
    {
      "id": "ratingBasis",
      "label": "What the Catalogue Rating Is Quoted At",
      "type": "select",
      "defaultValue": "en442",
      "options": [
        {
          "value": "en442",
          "label": "EN 442 — ΔT50 (UK, Europe, Australia and most catalogues)"
        },
        {
          "value": "us180",
          "label": "US catalogue — 180 °F average water, 65 °F room"
        },
        {
          "value": "custom",
          "label": "Another rating point — enter its excess temperature"
        }
      ],
      "help": "The conditions the output printed in the catalogue was measured at."
    },
    {
      "id": "customRatingDeltaT",
      "label": "Excess Temperature the Catalogue Rating Uses",
      "type": "number",
      "dimension": "tempdelta",
      "defaultValue": 50,
      "min": 5,
      "max": 120,
      "step": 0.5,
      "help": "Mean water temperature minus room temperature, at the catalogue's rating point."
    }
  ],
  "sources": [
    {
      "label": "EN 442-2: a radiator's output at other conditions is its rated output × (ΔT ÷ ΔT at rating)^n, where ΔT is the excess of the mean water temperature over the room air and n is the radiator exponent the manufacturer publishes. The standard rating conditions are 75 °C flow, 65 °C return and 20 °C air — a 50 K excess, 'ΔT50'"
    },
    {
      "label": "EN 442-2: where (return − room) ÷ (flow − room) falls below 0.7, the logarithmic mean excess temperature, (flow − return) ÷ ln((flow − room) ÷ (return − room)), is used in place of the arithmetic mean"
    },
    {
      "label": "US hydronic catalogues quote output against average water temperature; the row most often read is 180 °F average water in a 65 °F room, an excess of 115 °F-degrees (63.9 K), and the same ratio method applies with that excess in place of 50 K"
    }
  ],
  "testCases": [
    {
      "name": "EN 442 standard conditions, 75/65 in a 20 room — the rating comes back unchanged (in BTU/h)",
      "inputs": {
        "roomHeatLoss": 1000,
        "flowTemp": 75,
        "returnTemp": 65,
        "roomTemp": 20,
        "exponent": 1.3,
        "ratingBasis": "en442",
        "customRatingDeltaT": 50
      },
      "expected": 3412.142,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Output at these conditions, as a share of the catalogue rating",
          "value": 100,
          "unit": "%"
        },
        {
          "label": "Mean water temperature",
          "value": 70,
          "unit": "°C"
        },
        {
          "label": "Excess temperature — mean water minus room",
          "value": 50,
          "unit": "Δ°C"
        },
        {
          "label": "Excess temperature the catalogue rating is quoted at",
          "value": 50,
          "unit": "Δ°C"
        },
        {
          "label": "The same rating in watts, as European-made panels are catalogued",
          "value": 1000,
          "unit": "W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "Heat pump at 45/40 in a 21 room — about a third of the rating, so three times the loss",
      "inputs": {
        "roomHeatLoss": 1000,
        "flowTemp": 45,
        "returnTemp": 40,
        "roomTemp": 21,
        "exponent": 1.3,
        "ratingBasis": "en442",
        "customRatingDeltaT": 50
      },
      "expected": 10221.581,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Output at these conditions, as a share of the catalogue rating",
          "value": 33.38174169271837,
          "unit": "%"
        },
        {
          "label": "Mean water temperature",
          "value": 42.5,
          "unit": "°C"
        },
        {
          "label": "Excess temperature — mean water minus room",
          "value": 21.5,
          "unit": "Δ°C"
        },
        {
          "label": "Excess temperature the catalogue rating is quoted at",
          "value": 50,
          "unit": "Δ°C"
        },
        {
          "label": "The same rating in watts, as European-made panels are catalogued",
          "value": 2995.6495655771373,
          "unit": "W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "A 20-degree drop at 55/35 in a 20 room — below EN 442's 0.7 ratio, so the log-mean applies",
      "inputs": {
        "roomHeatLoss": 1000,
        "flowTemp": 55,
        "returnTemp": 35,
        "roomTemp": 20,
        "exponent": 1.3,
        "ratingBasis": "en442",
        "customRatingDeltaT": 50
      },
      "expected": 9053.073,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Output at these conditions, as a share of the catalogue rating",
          "value": 37.69042599606158,
          "unit": "%"
        },
        {
          "label": "Mean water temperature",
          "value": 45,
          "unit": "°C"
        },
        {
          "label": "Excess temperature — log-mean, as EN 442 requires here",
          "value": 23.604450022876573,
          "unit": "Δ°C"
        },
        {
          "label": "Excess temperature the catalogue rating is quoted at",
          "value": 50,
          "unit": "Δ°C"
        },
        {
          "label": "The same rating in watts, as European-made panels are catalogued",
          "value": 2653.1936786930823,
          "unit": "W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 1
    },
    {
      "name": "US basis at its own reference, 190/170 °F in a 65 °F room — 10,000 BTU/h comes back unchanged",
      "inputs": {
        "roomHeatLoss": 2930.7107017222,
        "flowTemp": 87.77777777777779,
        "returnTemp": 76.66666666666667,
        "roomTemp": 18.333333333333336,
        "exponent": 1.3,
        "ratingBasis": "us180",
        "customRatingDeltaT": 50
      },
      "expected": 10000,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Output at these conditions, as a share of the catalogue rating",
          "value": 100,
          "unit": "%"
        },
        {
          "label": "Mean water temperature",
          "value": 82.22222222222223,
          "unit": "°C"
        },
        {
          "label": "Excess temperature — mean water minus room",
          "value": 63.88888888888889,
          "unit": "Δ°C"
        },
        {
          "label": "Excess temperature the catalogue rating is quoted at",
          "value": 63.88888888888889,
          "unit": "Δ°C"
        },
        {
          "label": "The same rating in watts, as European-made panels are catalogued",
          "value": 2930.7107017222,
          "unit": "W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 2
    },
    {
      "name": "Another rating point — a catalogue quoting 80 °C mean water in a 20 °C room, a 60-degree excess",
      "inputs": {
        "roomHeatLoss": 1000,
        "flowTemp": 45,
        "returnTemp": 40,
        "roomTemp": 21,
        "exponent": 1.3,
        "ratingBasis": "custom",
        "customRatingDeltaT": 60
      },
      "expected": 12955.485,
      "toleranceDecimalPlaces": 1,
      "unit": "BTU/h",
      "confidence": "medium",
      "steps": [
        {
          "label": "Output at these conditions, as a share of the catalogue rating",
          "value": 26.33742866873766,
          "unit": "%"
        },
        {
          "label": "Mean water temperature",
          "value": 42.5,
          "unit": "°C"
        },
        {
          "label": "Excess temperature — mean water minus room",
          "value": 21.5,
          "unit": "Δ°C"
        },
        {
          "label": "Excess temperature the catalogue rating is quoted at",
          "value": 60,
          "unit": "Δ°C"
        },
        {
          "label": "The same rating in watts, as European-made panels are catalogued",
          "value": 3796.877867530754,
          "unit": "W"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ]
}