  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "pump-drawdown-time-calculator",
  "category": "pools-water",
  "title": "Pump Drain Time Calculator",
  "description": "Hours to drain a pool, flooded basement or tank — from the pump's real operating point on its hose, not the zero-head number on the box.",
  "url": "https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/pump-drawdown-time-calculator.json",
  "inputCount": 6,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-09-02",
  "citation": {
    "author": "Craft Quantities",
    "title": "Pump Drain Time Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Pump Drain Time Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/",
      "apa": "Craft Quantities. (2026). Pump Drain Time Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/",
      "harvard": "Craft Quantities (2026) Pump Drain Time Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/",
      "bibtex": "@misc{craftquantities-calculators-pools-water-pump-drawdown-time-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Pump Drain Time Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "volume",
      "label": "Water volume to remove",
      "type": "number",
      "dimension": "volume",
      "defaultValue": 50000,
      "min": 0.1,
      "max": 5000000,
      "help": "The volume of water to move — a pool, a flooded floor, a tank."
    },
    {
      "id": "ratedFlow",
      "label": "Pump rated flow (at zero head)",
      "type": "number",
      "dimension": "flow",
      "defaultValue": 200,
      "min": 0.1,
      "max": 5000,
      "help": "The headline flow on the pump's box or plate — measured with no lift and no hose."
    },
    {
      "id": "maxHead",
      "label": "Pump maximum head",
      "type": "number",
      "dimension": "length",
      "defaultValue": 8,
      "min": 0.01,
      "max": 100,
      "help": "The lift at which the pump's flow falls to zero — on the same plate as the rated flow."
    },
    {
      "id": "staticLift",
      "label": "Vertical lift",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2,
      "min": 0,
      "max": 50,
      "help": "Height from the water surface up to the hose outlet."
    },
    {
      "id": "hoseDia",
      "label": "Hose inside diameter",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.025,
      "min": 0.01,
      "max": 0.15,
      "help": "The inside bore of the discharge hose — the single most sensitive number here."
    },
    {
      "id": "hoseLength",
      "label": "Hose length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 10,
      "min": 0.01,
      "max": 200,
      "help": "Total discharge hose length, including the part lying flat."
    }
  ],
  "sources": [
    {
      "label": "Hazen–Williams empirical head-loss formula, h_f = 10.67·L·Q^1.852 / (C^1.852·d^4.87), with C = 150 for smooth plastic/rubber hose — standard engineering hydraulics form (SI units)"
    },
    {
      "label": "Pump performance approximated as a linear curve from rated flow at zero head to zero flow at rated maximum head — the standard first approximation for small utility and submersible pumps; the manufacturer's published curve governs where one exists"
    }
  ],
  "testCases": [
    {
      "name": "50 m³ (50,000 L) pool, 200 L/min pump, 8 m head, 2 m lift, 25 mm × 10 m hose",
      "inputs": {
        "volume": 50000,
        "ratedFlow": 200,
        "maxHead": 8,
        "staticLift": 2,
        "hoseDia": 0.025,
        "hoseLength": 10
      },
      "expected": 10.648,
      "toleranceDecimalPlaces": 0.01,
      "unit": "hours",
      "confidence": "medium",
      "steps": [
        {
          "label": "Delivered flow at the operating point",
          "value": 78.26282428228797,
          "unit": "L/min"
        },
        {
          "label": "Share of rated flow surviving lift and hose",
          "value": 39.13141214114398,
          "unit": "%"
        },
        {
          "label": "Friction head in the hose",
          "value": 2.8694870287084835,
          "unit": "m"
        },
        {
          "label": "Total dynamic head",
          "value": 4.869487028708484,
          "unit": "m"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "10 m³ (10,000 L) through a 32 mm × 5 m hose, 1 m lift",
      "inputs": {
        "volume": 10000,
        "ratedFlow": 100,
        "maxHead": 6,
        "staticLift": 1,
        "hoseDia": 0.032,
        "hoseLength": 5
      },
      "expected": 2.18,
      "toleranceDecimalPlaces": 2,
      "unit": "hours",
      "confidence": "medium",
      "steps": [
        {
          "label": "Delivered flow at the operating point",
          "value": 76.45187494427394,
          "unit": "L/min"
        },
        {
          "label": "Share of rated flow surviving lift and hose",
          "value": 76.45187494427394,
          "unit": "%"
        },
        {
          "label": "Friction head in the hose",
          "value": 0.4128875033435627,
          "unit": "m"
        },
        {
          "label": "Total dynamic head",
          "value": 1.4128875033435628,
          "unit": "m"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Lift exceeds maximum head: 0 means never, flagged low confidence",
      "inputs": {
        "volume": 5000,
        "ratedFlow": 100,
        "maxHead": 5,
        "staticLift": 6,
        "hoseDia": 0.025,
        "hoseLength": 10
      },
      "expected": 0,
      "toleranceDecimalPlaces": 0,
      "unit": "hours",
      "confidence": "low",
      "steps": [
        {
          "label": "Delivered flow at the operating point",
          "value": 0,
          "unit": "L/min"
        },
        {
          "label": "Share of rated flow surviving lift and hose",
          "value": 0,
          "unit": "%"
        },
        {
          "label": "Friction head in the hose",
          "value": 0,
          "unit": "m"
        },
        {
          "label": "Total dynamic head",
          "value": 6,
          "unit": "m"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "500 L flooded floor — minutes, not days (the 1000x regression)",
      "inputs": {
        "volume": 500,
        "ratedFlow": 200,
        "maxHead": 8,
        "staticLift": 2,
        "hoseDia": 0.025,
        "hoseLength": 10
      },
      "expected": 0.1065,
      "toleranceDecimalPlaces": 2,
      "unit": "hours",
      "confidence": "medium",
      "steps": [
        {
          "label": "Delivered flow at the operating point",
          "value": 78.26282428228797,
          "unit": "L/min"
        },
        {
          "label": "Share of rated flow surviving lift and hose",
          "value": 39.13141214114398,
          "unit": "%"
        },
        {
          "label": "Friction head in the hose",
          "value": 2.8694870287084835,
          "unit": "m"
        },
        {
          "label": "Total dynamic head",
          "value": 4.869487028708484,
          "unit": "m"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}