  "title": "Timber Post Bearing Area Calculator",
  "description": "Calculate the minimum bearing area required where a timber post bears on a beam, based on allowable perpendicular-to-grain stress.",
  "url": "https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/post-bearing-area-calculator.json",
  "inputCount": 2,
  "testCaseCount": 2,
  "sourceCount": 1,
  "lastVerified": "2026-09-02",
  "translations": {
    "es-US": "https://craftquantities.com/es/calculators/materials-quantities/post-bearing-area-calculator/"
  },
  "citation": {
    "author": "Craft Quantities",
    "title": "Timber Post Bearing Area Calculator",
    "version": "1.0.1",
    "sourcesChecked": "2026-09-02",
    "url": "https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Timber Post Bearing Area Calculator. Version 1.0.1. Sources checked 2026-09-02. https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/",
      "apa": "Craft Quantities. (2026). Timber Post Bearing Area Calculator (Version 1.0.1) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/",
      "harvard": "Craft Quantities (2026) Timber Post Bearing Area Calculator (Version 1.0.1). Available at: https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-post-bearing-area-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Timber Post Bearing Area Calculator},\n  version      = {1.0.1},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/post-bearing-area-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "axialLoad",
      "label": "Axial Load",
      "type": "number",
      "dimension": "force",
      "defaultValue": 40000,
      "min": 2000,
      "max": 300000,
      "step": 1000,
      "help": "The compressive axial load the post transfers into the beam below it."
    },
    {
      "id": "allowableBearingStress",
      "label": "Allowable Bearing Stress Fc-perp",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 3000000,
      "min": 1000000,
      "max": 8000000,
      "step": 100000,
      "help": "The species/grade's allowable compression stress perpendicular to grain, from the NDS design values."
    }
  ],
  "sources": [
    {
      "label": "Required bearing area = axial load ÷ allowable compression stress perpendicular to grain (Fc-perp), the standard NDS timber bearing check"
    }
  ],
  "testCases": [
    {
      "name": "40kN load, 3.0MPa Fc-perp",
      "inputs": {
        "axialLoad": 40000,
        "allowableBearingStress": 3000000
      },
      "expected": 133.33,
      "toleranceDecimalPlaces": 2,
      "unit": "cm²",
      "confidence": "high",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    },
    {
      "name": "60kN load, 3.5MPa Fc-perp",
      "inputs": {
        "axialLoad": 60000,
        "allowableBearingStress": 3500000
      },
      "expected": 171.43,
      "toleranceDecimalPlaces": 2,
      "unit": "cm²",
      "confidence": "high",
      "steps": [],
      "basis": "sole-source",
      "sourceIndex": 0
    }
  ]
}