  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "pool-heater-sizing-calculator",
  "category": "pools-water",
  "title": "Pool Heater Sizing Calculator",
  "description": "Estimate the heater output needed to raise a pool to temperature in a target time, and what a cover saves.",
  "url": "https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/pool-heater-sizing-calculator.json",
  "inputCount": 4,
  "testCaseCount": 4,
  "sourceCount": 2,
  "lastVerified": "2026-10-31",
  "citation": {
    "author": "Craft Quantities",
    "title": "Pool Heater Sizing Calculator",
    "version": "1.1.0",
    "sourcesChecked": "2026-10-31",
    "url": "https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Pool Heater Sizing Calculator. Version 1.1.0. Sources checked 2026-10-31. https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/",
      "apa": "Craft Quantities. (2026). Pool Heater Sizing Calculator (Version 1.1.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/",
      "harvard": "Craft Quantities (2026) Pool Heater Sizing Calculator (Version 1.1.0). Available at: https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/",
      "bibtex": "@misc{craftquantities-calculators-pools-water-pool-heater-sizing-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Pool Heater Sizing Calculator},\n  version      = {1.1.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "volume",
      "label": "Pool volume",
      "type": "number",
      "dimension": "volume",
      "defaultValue": 50000,
      "min": 0.1,
      "max": 10000000,
      "step": 500,
      "help": "Water volume."
    },
    {
      "id": "temperatureRise",
      "label": "Temperature rise",
      "type": "number",
      "dimension": "tempdelta",
      "defaultValue": 8,
      "min": 1,
      "max": 30,
      "step": 0.5,
      "help": "How far the water must be raised."
    },
    {
      "id": "heatUpHours",
      "label": "Heat-up time (hours)",
      "type": "number",
      "defaultValue": 24,
      "min": 1,
      "max": 336,
      "step": 1,
      "help": "How quickly you want to reach temperature."
    },
    {
      "id": "covered",
      "label": "Cover used overnight",
      "type": "select",
      "defaultValue": "yes",
      "options": [
        {
          "value": "yes",
          "label": "Yes — cover on when not in use"
        },
        {
          "value": "no",
          "label": "No cover"
        }
      ],
      "help": "A cover suppresses evaporation, which is most of the loss."
    }
  ],
  "sources": [
    {
      "label": "Specific heat capacity of water 4.186 kJ/kg·K; 1 m³ of water = 1000 kg"
    },
    {
      "label": "Evaporation is the dominant heat loss from an uncovered pool, typically 50-70% of the total — ASHRAE Handbook, Applications: Natatoriums"
    }
  ],
  "testCases": [
    {
      "name": "50 m³, 8 K rise over 24 h, covered",
      "inputs": {
        "volume": 50000,
        "temperatureRise": 8,
        "heatUpHours": 24,
        "covered": "yes"
      },
      "expected": 22.71,
      "toleranceDecimalPlaces": 1,
      "unit": "kW",
      "confidence": "low",
      "steps": [
        {
          "label": "Energy to raise the water",
          "value": 465.1111111111111,
          "unit": "kWh"
        },
        {
          "label": "Heat-up power",
          "value": 19.37962962962963,
          "unit": "kW"
        },
        {
          "label": "Standing loss allowance",
          "value": 3.333333333333334,
          "unit": "kW"
        },
        {
          "label": "BTU/h",
          "value": 77499.8465376195,
          "unit": "BTU/h"
        },
        {
          "label": "Approximate surface area used",
          "value": 33.333333333333336,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Uncovered raises the standing loss",
      "inputs": {
        "volume": 50000,
        "temperatureRise": 8,
        "heatUpHours": 24,
        "covered": "no"
      },
      "expected": 29.37,
      "toleranceDecimalPlaces": 0,
      "unit": "kW",
      "confidence": "low",
      "steps": [
        {
          "label": "Energy to raise the water",
          "value": 465.1111111111111,
          "unit": "kWh"
        },
        {
          "label": "Heat-up power",
          "value": 19.37962962962963,
          "unit": "kW"
        },
        {
          "label": "Standing loss allowance",
          "value": 10,
          "unit": "kW"
        },
        {
          "label": "BTU/h",
          "value": 100247.45742513928,
          "unit": "BTU/h"
        },
        {
          "label": "Approximate surface area used",
          "value": 33.333333333333336,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A slower heat-up needs less power",
      "inputs": {
        "volume": 50000,
        "temperatureRise": 8,
        "heatUpHours": 48,
        "covered": "yes"
      },
      "expected": 13.0231,
      "toleranceDecimalPlaces": 2,
      "unit": "kW",
      "confidence": "low",
      "steps": [
        {
          "label": "Energy to raise the water",
          "value": 465.1111111111111,
          "unit": "kWh"
        },
        {
          "label": "Heat-up power",
          "value": 9.689814814814815,
          "unit": "kW"
        },
        {
          "label": "Standing loss allowance",
          "value": 3.333333333333334,
          "unit": "kW"
        },
        {
          "label": "BTU/h",
          "value": 44436.82599068969,
          "unit": "BTU/h"
        },
        {
          "label": "Approximate surface area used",
          "value": 33.333333333333336,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "A larger pool needs more",
      "inputs": {
        "volume": 100000,
        "temperatureRise": 8,
        "heatUpHours": 24,
        "covered": "yes"
      },
      "expected": 45.43,
      "toleranceDecimalPlaces": 1,
      "unit": "kW",
      "confidence": "low",
      "steps": [
        {
          "label": "Energy to raise the water",
          "value": 930.2222222222222,
          "unit": "kWh"
        },
        {
          "label": "Heat-up power",
          "value": 38.75925925925926,
          "unit": "kW"
        },
        {
          "label": "Standing loss allowance",
          "value": 6.666666666666668,
          "unit": "kW"
        },
        {
          "label": "BTU/h",
          "value": 154999.693075239,
          "unit": "BTU/h"
        },
        {
          "label": "Approximate surface area used",
          "value": 66.66666666666667,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}