  "version": "v1",
  "source": "https://craftquantities.com",
  "licence": "CC BY 4.0",
  "licenceUrl": "https://creativecommons.org/licenses/by/4.0/",
  "attribution": "Craft Quantities — craftquantities.com",
  "documentation": "https://craftquantities.com/api/",
  "versioning": "Fields are added, never removed or repurposed, within a version. A breaking change becomes /api/v2/ and v1 keeps being built.",
  "slug": "pier-adfreeze-uplift-calculator",
  "category": "materials-quantities",
  "title": "Pier Adfreeze Uplift Calculator",
  "description": "Check a frost-zone pier: adfreeze bond dragging the shaft up, against the dead load, self-weight and bell holding it down.",
  "url": "https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/pier-adfreeze-uplift-calculator.json",
  "inputCount": 8,
  "testCaseCount": 3,
  "sourceCount": 5,
  "lastVerified": "2026-08-30",
  "citation": {
    "author": "Craft Quantities",
    "title": "Pier Adfreeze Uplift Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-08-30",
    "url": "https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Pier Adfreeze Uplift Calculator. Version 1.0.0. Sources checked 2026-08-30. https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/",
      "apa": "Craft Quantities. (2026). Pier Adfreeze Uplift Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/",
      "harvard": "Craft Quantities (2026) Pier Adfreeze Uplift Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-pier-adfreeze-uplift-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Pier Adfreeze Uplift Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/pier-adfreeze-uplift-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "frostDepth",
      "label": "Design Frost Depth",
      "type": "number",
      "dimension": "length",
      "defaultValue": 1.5,
      "min": 0.3,
      "max": 4,
      "step": 0.1,
      "help": "The design frost penetration at this site."
    },
    {
      "id": "shaftDiameter",
      "label": "Shaft Diameter",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.3,
      "min": 0.1,
      "max": 1.2,
      "step": 0.01,
      "help": "The outside diameter of the pier shaft through the frost zone."
    },
    {
      "id": "adfreezeStress",
      "label": "Adfreeze Bond Stress",
      "type": "number",
      "dimension": "pressure",
      "defaultValue": 65000,
      "min": 5000,
      "max": 300000,
      "step": 1000,
      "help": "The bond stress developed between frozen soil and the shaft face."
    },
    {
      "id": "deadLoad",
      "label": "Dead Load Carried",
      "type": "number",
      "dimension": "force",
      "defaultValue": 20000,
      "min": 0,
      "max": 2000000,
      "step": 1000,
      "help": "The permanent load the pier carries, with no live or snow contribution."
    },
    {
      "id": "pierLength",
      "label": "Total Pier Depth",
      "type": "number",
      "dimension": "length",
      "defaultValue": 2.4,
      "min": 0.5,
      "max": 8,
      "step": 0.1,
      "help": "Depth from finished grade to the underside of the base or bell."
    },
    {
      "id": "bellDiameter",
      "label": "Bell or Pad Diameter",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.6,
      "min": 0.1,
      "max": 2,
      "step": 0.05,
      "help": "Diameter of the bell or footing pad at the base of the pier."
    },
    {
      "id": "soilDensity",
      "label": "Soil Bulk Density",
      "type": "number",
      "dimension": "density",
      "defaultValue": 1800,
      "min": 1200,
      "max": 2400,
      "step": 25,
      "help": "Bulk density of the soil resting over the projecting bell."
    },
    {
      "id": "verticalSteelArea",
      "label": "Vertical Steel Area (mm²)",
      "type": "number",
      "defaultValue": 800,
      "min": 100,
      "max": 8000,
      "step": 10,
      "help": "Combined cross-sectional area of the vertical bars, in square millimetres."
    }
  ],
  "sources": [
    {
      "label": "Uplift = adfreeze bond stress × the shaft's bonded surface area inside the frost zone (π × diameter × frost depth). Restraint = dead load + pier self-weight + the weight of soil standing over the bell's projecting annulus."
    },
    {
      "label": "The adfreeze bond stress is a SITE-SPECIFIC soil property you supply from the geotechnical report; this page applies no table of published values, because bond stress varies with soil type, moisture, freezing rate and shaft finish."
    },
    {
      "label": "ASCE/SEI 32, Design and Construction of Frost-Protected Shallow Foundations — the standard the frost-heave design case belongs to"
    },
    {
      "label": "ACI 318, Building Code Requirements for Structural Concrete — the code governing development of the vertical bars that carry the tension computed here"
    },
    {
      "label": "Normalweight concrete self-weight taken as 2,400 kg/m³ (about 150 pcf), the conventional design value"
    }
  ],
  "testCases": [
    {
      "name": "300 mm shaft, 1.5 m frost, belled, uplift governs",
      "inputs": {
        "frostDepth": 1.5,
        "shaftDiameter": 0.3,
        "adfreezeStress": 65000,
        "deadLoad": 20000,
        "pierLength": 2.4,
        "bellDiameter": 0.6,
        "soilDensity": 1800,
        "verticalSteelArea": 800
      },
      "expected": 58.915,
      "toleranceDecimalPlaces": 2,
      "unit": "kN",
      "confidence": "medium",
      "steps": [
        {
          "label": "Adfreeze uplift on the shaft",
          "value": 91.89158511750145,
          "unit": "kN"
        },
        {
          "label": "Restraint from dead load, pier and bell",
          "value": 32.97654002997266,
          "unit": "kN"
        },
        {
          "label": "Tension the vertical steel must carry",
          "value": 58.915045087528796,
          "unit": "kN"
        },
        {
          "label": "Stress in the vertical steel",
          "value": 73.643806359411,
          "unit": "MPa"
        },
        {
          "label": "Bonded shaft area inside the frost zone",
          "value": 1.413716694115407,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Same pier under a heavier dead load — held down",
      "inputs": {
        "frostDepth": 1.5,
        "shaftDiameter": 0.3,
        "adfreezeStress": 65000,
        "deadLoad": 120000,
        "pierLength": 2.4,
        "bellDiameter": 0.6,
        "soilDensity": 1800,
        "verticalSteelArea": 800
      },
      "expected": -41.085,
      "toleranceDecimalPlaces": 2,
      "unit": "kN",
      "confidence": "medium",
      "steps": [
        {
          "label": "Adfreeze uplift on the shaft",
          "value": 91.89158511750145,
          "unit": "kN"
        },
        {
          "label": "Restraint from dead load, pier and bell",
          "value": 132.97654002997265,
          "unit": "kN"
        },
        {
          "label": "Tension the vertical steel must carry",
          "value": 0,
          "unit": "kN"
        },
        {
          "label": "Stress in the vertical steel",
          "value": 0,
          "unit": "MPa"
        },
        {
          "label": "Bonded shaft area inside the frost zone",
          "value": 1.413716694115407,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "450 mm shaft, 2 m frost, higher bond stress",
      "inputs": {
        "frostDepth": 2,
        "shaftDiameter": 0.45,
        "adfreezeStress": 80000,
        "deadLoad": 30000,
        "pierLength": 3,
        "bellDiameter": 0.9,
        "soilDensity": 1900,
        "verticalSteelArea": 1200
      },
      "expected": 158.294,
      "toleranceDecimalPlaces": 2,
      "unit": "kN",
      "confidence": "medium",
      "steps": [
        {
          "label": "Adfreeze uplift on the shaft",
          "value": 226.1946710584651,
          "unit": "kN"
        },
        {
          "label": "Restraint from dead load, pier and bell",
          "value": 67.90023109715571,
          "unit": "kN"
        },
        {
          "label": "Tension the vertical steel must carry",
          "value": 158.2944399613094,
          "unit": "kN"
        },
        {
          "label": "Stress in the vertical steel",
          "value": 131.91203330109118,
          "unit": "MPa"
        },
        {
          "label": "Bonded shaft area inside the frost zone",
          "value": 2.827433388230814,
          "unit": "m²"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}