  "slug": "mullion-stack-joint-gap-calculator",
  "category": "materials-quantities",
  "title": "Mullion Stack Joint Setting Gap Calculator",
  "description": "Work out the gap to set at a curtain wall stack joint against the thermometer reading on the day of installation, not against the season it happens to be.",
  "url": "https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/mullion-stack-joint-gap-calculator.json",
  "inputCount": 6,
  "testCaseCount": 3,
  "sourceCount": 2,
  "lastVerified": "2026-08-30",
  "citation": {
    "author": "Craft Quantities",
    "title": "Mullion Stack Joint Setting Gap Calculator",
    "version": "1.0.0",
    "sourcesChecked": "2026-08-30",
    "url": "https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Mullion Stack Joint Setting Gap Calculator. Version 1.0.0. Sources checked 2026-08-30. https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/",
      "apa": "Craft Quantities. (2026). Mullion Stack Joint Setting Gap Calculator (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/",
      "harvard": "Craft Quantities (2026) Mullion Stack Joint Setting Gap Calculator (Version 1.0.0). Available at: https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/",
      "bibtex": "@misc{craftquantities-calculators-materials-quantities-mullion-stack-joint-gap-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Mullion Stack Joint Setting Gap Calculator},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/materials-quantities/mullion-stack-joint-gap-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "mullionLength",
      "label": "Floor-to-Floor Mullion Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 3.6,
      "min": 1,
      "max": 8,
      "step": 0.1,
      "help": "The length of one mullion between stack joints — usually the floor-to-floor dimension."
    },
    {
      "id": "alloy",
      "label": "Mullion Alloy",
      "type": "select",
      "defaultValue": "aluminium",
      "options": [
        {
          "value": "aluminium",
          "label": "Aluminium extrusion (6000 series)"
        },
        {
          "value": "steel",
          "label": "Carbon steel"
        },
        {
          "value": "stainless",
          "label": "Austenitic stainless steel"
        }
      ],
      "help": "The material of the mullion itself, which sets how far it moves per degree."
    },
    {
      "id": "designMinTemp",
      "label": "Coldest Design Metal Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": -20,
      "min": -50,
      "max": 10,
      "step": 1,
      "help": "The lowest temperature the mullion metal itself is expected to reach in service."
    },
    {
      "id": "designMaxTemp",
      "label": "Hottest Design Metal Temperature",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 70,
      "min": 20,
      "max": 100,
      "step": 1,
      "help": "The highest temperature the mullion metal itself is expected to reach in service."
    },
    {
      "id": "ambientTemp",
      "label": "Metal Temperature Measured at Installation",
      "type": "number",
      "dimension": "temperature",
      "defaultValue": 15,
      "min": -30,
      "max": 50,
      "step": 1,
      "help": "What the mullion is reading right now, on the face being installed."
    },
    {
      "id": "minimumClosedGap",
      "label": "Residual Gap Required at the Hottest Temperature",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.0015,
      "min": 0,
      "max": 0.01,
      "step": 0.0005,
      "help": "How much clearance must survive when the mullion is at its hottest and the joint is at its tightest."
    }
  ],
  "sources": [
    {
      "label": "Linear thermal expansion, ΔL = α × L × ΔT — the gap set today is the residual gap at the hottest design temperature plus the expansion still to come between today's reading and that temperature"
    },
    {
      "label": "Coefficients of linear thermal expansion as published for each alloy family: aluminium extrusion 23.6 × 10⁻⁶ per °C (Aluminum Design Manual, The Aluminum Association), structural carbon steel 11.7 × 10⁻⁶ per °C (AISC Steel Construction Manual), austenitic stainless steel 17.3 × 10⁻⁶ per °C"
    }
  ],
  "testCases": [
    {
      "name": "3.6 m aluminium mullion, -20 to 70 °C range, set at 15 °C",
      "inputs": {
        "mullionLength": 3.6,
        "alloy": "aluminium",
        "designMinTemp": -20,
        "designMaxTemp": 70,
        "ambientTemp": 15,
        "minimumClosedGap": 0.0015
      },
      "expected": 6.1728,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total movement across the design range",
          "value": 7.6464,
          "unit": "mm"
        },
        {
          "label": "Gap at the coldest design temperature",
          "value": 9.1464,
          "unit": "mm"
        },
        {
          "label": "Gap at the hottest design temperature",
          "value": 1.5,
          "unit": "mm"
        },
        {
          "label": "Expansion still to come from today's reading",
          "value": 4.6728000000000005,
          "unit": "mm"
        },
        {
          "label": "Contraction still to come from today's reading",
          "value": 2.9736,
          "unit": "mm"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "6 m steel mullion, -20 to 60 °C range, set at 10 °C",
      "inputs": {
        "mullionLength": 6,
        "alloy": "steel",
        "designMinTemp": -20,
        "designMaxTemp": 60,
        "ambientTemp": 10,
        "minimumClosedGap": 0.002
      },
      "expected": 5.51,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total movement across the design range",
          "value": 5.616,
          "unit": "mm"
        },
        {
          "label": "Gap at the coldest design temperature",
          "value": 7.616,
          "unit": "mm"
        },
        {
          "label": "Gap at the hottest design temperature",
          "value": 2,
          "unit": "mm"
        },
        {
          "label": "Expansion still to come from today's reading",
          "value": 3.5100000000000002,
          "unit": "mm"
        },
        {
          "label": "Contraction still to come from today's reading",
          "value": 2.106,
          "unit": "mm"
        }
      ],
      "basis": "ambiguous"
    },
    {
      "name": "Installed at the hottest design temperature — gap is the residual",
      "inputs": {
        "mullionLength": 3.6,
        "alloy": "aluminium",
        "designMinTemp": -20,
        "designMaxTemp": 45,
        "ambientTemp": 45,
        "minimumClosedGap": 0.0015
      },
      "expected": 1.5,
      "toleranceDecimalPlaces": 3,
      "unit": "mm",
      "confidence": "high",
      "steps": [
        {
          "label": "Total movement across the design range",
          "value": 5.5224,
          "unit": "mm"
        },
        {
          "label": "Gap at the coldest design temperature",
          "value": 7.0224,
          "unit": "mm"
        },
        {
          "label": "Gap at the hottest design temperature",
          "value": 1.5,
          "unit": "mm"
        },
        {
          "label": "Expansion still to come from today's reading",
          "value": 0,
          "unit": "mm"
        },
        {
          "label": "Contraction still to come from today's reading",
          "value": 5.5224,
          "unit": "mm"
        }
      ],
      "basis": "ambiguous"
    }
  ]
}