  "title": "Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)",
  "description": "How many luminaires a room needs for a target average illuminance by the lumen method, with the room index and a grid inside the spacing-to-height ratio.",
  "url": "https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/",
  "json": "https://craftquantities.com/api/v1/calculators/lumen-method-lighting-calculator.json",
  "inputCount": 9,
  "testCaseCount": 2,
  "sourceCount": 3,
  "lastVerified": "2026-09-22",
  "citation": {
    "author": "Craft Quantities",
    "title": "Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)",
    "version": "1.0.0",
    "sourcesChecked": "2026-09-22",
    "url": "https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/",
    "accessDate": null,
    "accessDateNote": "Add the date you retrieved this. It is deliberately absent: a static file cannot know when you read it, and the build date would be wrong.",
    "permanentVersionedUrl": null,
    "permanentVersionedUrlNote": "Not offered. This site keeps no archive of previous builds, so any such URL would resolve to the current page or to nothing. The version and sourcesChecked fields identify the calculation instead.",
    "formats": {
      "plain": "Craft Quantities. Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing). Version 1.0.0. Sources checked 2026-09-22. https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/",
      "apa": "Craft Quantities. (2026). Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing) (Version 1.0.0) [Web calculator]. Retrieved from https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/",
      "harvard": "Craft Quantities (2026) Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing) (Version 1.0.0). Available at: https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/",
      "bibtex": "@misc{craftquantities-calculators-electrical-lumen-method-lighting-calculator,\n  author       = {{Craft Quantities}},\n  title        = {Lumen Method Lighting Calculator (Room Index, Luminaire Count and Spacing)},\n  version      = {1.0.0},\n  year         = {2026},\n  howpublished = {\\url{https://craftquantities.com/calculators/electrical/lumen-method-lighting-calculator/}},\n}"
    }
  },
  "inputs": [
    {
      "id": "roomLength",
      "label": "Room Length",
      "type": "number",
      "dimension": "length",
      "defaultValue": 30,
      "min": 1,
      "max": 500,
      "step": 0.1,
      "help": "The longer dimension of the room."
    },
    {
      "id": "roomWidth",
      "label": "Room Width",
      "type": "number",
      "dimension": "length",
      "defaultValue": 20,
      "min": 1,
      "max": 500,
      "step": 0.1,
      "help": "The shorter dimension."
    },
    {
      "id": "luminaireHeight",
      "label": "Height of the Luminaires Above the Floor",
      "type": "number",
      "dimension": "length",
      "defaultValue": 6,
      "min": 2,
      "max": 50,
      "step": 0.05,
      "help": "The height the luminaires hang or sit at, measured from the floor."
    },
    {
      "id": "workingPlane",
      "label": "Height of the Working Plane Above the Floor",
      "type": "number",
      "dimension": "length",
      "defaultValue": 0.9,
      "min": 0,
      "max": 1.5,
      "step": 0.05,
      "help": "The surface the light is designed for — a desk, a bench, or the floor itself."
    },
    {
      "id": "targetIlluminance",
      "label": "Target Average Illuminance",
      "type": "number",
      "dimension": "illuminance",
      "defaultValue": 500,
      "min": 10,
      "max": 5000,
      "step": 5,
      "help": "The maintained average the task needs, from BS EN 12464-1 or the IES recommendation."
    },
    {
      "id": "luminaireLumens",
      "label": "Luminaire Output (lumens)",
      "type": "number",
      "defaultValue": 12000,
      "min": 100,
      "max": 200000,
      "step": 100,
      "help": "The light output of one luminaire, from its data sheet — the luminaire's lumens, not the bare lamp's."
    },
    {
      "id": "utilisationFactor",
      "label": "Utilisation Factor (UF)",
      "type": "number",
      "defaultValue": 0.6,
      "min": 0.1,
      "max": 1,
      "step": 0.01,
      "help": "The share of the lumens that reaches the working plane, read from the luminaire's table at this room index and these surface reflectances."
    },
    {
      "id": "maintenanceFactor",
      "label": "Maintenance Factor (MF)",
      "type": "number",
      "defaultValue": 0.8,
      "min": 0.3,
      "max": 1,
      "step": 0.01,
      "help": "The share of the initial output left at the end of the maintenance cycle, for dirt and lumen depreciation."
    },
    {
      "id": "spacingToHeight",
      "label": "Spacing-to-Height Ratio (SHR)",
      "type": "number",
      "defaultValue": 1.25,
      "min": 0.5,
      "max": 3,
      "step": 0.05,
      "help": "From the luminaire's photometric data: the widest pitch, as a multiple of the height above the working plane, that keeps the light even."
    }
  ],
  "sources": [
    {
      "label": "The lumen method (SLL Code for Lighting, CIBSE; IES Lighting Handbook): N = E × A ÷ (Φ × UF × MF); room index K = L × W ÷ (Hm × (L + W)), Hm the height of the luminaires above the working plane"
    },
    {
      "label": "Maximum spacing = the luminaire's spacing-to-height ratio (SHR, from its photometric data) × Hm"
    },
    {
      "label": "BS EN 12464-1, Lighting of work places — Indoor work places: maintained illuminance on the task area"
    }
  ],
  "testCases": [
    {
      "name": "The workspace guide's shop: 6.0 m fittings over 0.9 m benches (Hm 5.1), 30 × 20 m at 500 lx",
      "inputs": {
        "roomLength": 30,
        "roomWidth": 20,
        "luminaireHeight": 6,
        "workingPlane": 0.9,
        "targetIlluminance": 500,
        "luminaireLumens": 12000,
        "utilisationFactor": 0.6,
        "maintenanceFactor": 0.8,
        "spacingToHeight": 1.25
      },
      "expected": 53,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "high",
      "steps": [
        {
          "label": "Height of the luminaires above the working plane",
          "value": 5.1,
          "unit": "m"
        },
        {
          "label": "Room index K",
          "value": 2.3529411764705883
        },
        {
          "label": "Luminaires by the lumen method, before rounding up",
          "value": 52.083333333333336
        },
        {
          "label": "Rows along the length",
          "value": 9
        },
        {
          "label": "Luminaires in each row, across the width",
          "value": 6
        },
        {
          "label": "Luminaires in that grid",
          "value": 54
        },
        {
          "label": "Pitch along the length",
          "value": 3.3333333333333335,
          "unit": "m"
        },
        {
          "label": "Pitch across the width",
          "value": 3.3333333333333335,
          "unit": "m"
        },
        {
          "label": "Largest pitch the SHR allows",
          "value": 6.375,
          "unit": "m"
        },
        {
          "label": "Average illuminance the grid gives",
          "value": 518.4,
          "unit": "lx"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    },
    {
      "name": "An office: 12 × 8 m, recessed at 2.7 m over 0.8 m desks, 3,600 lm at UF 0.55",
      "inputs": {
        "roomLength": 12,
        "roomWidth": 8,
        "luminaireHeight": 2.7,
        "workingPlane": 0.8,
        "targetIlluminance": 500,
        "luminaireLumens": 3600,
        "utilisationFactor": 0.55,
        "maintenanceFactor": 0.8,
        "spacingToHeight": 1.5
      },
      "expected": 31,
      "toleranceDecimalPlaces": 0,
      "unit": "luminaires",
      "confidence": "high",
      "steps": [
        {
          "label": "Height of the luminaires above the working plane",
          "value": 1.9000000000000001,
          "unit": "m"
        },
        {
          "label": "Room index K",
          "value": 2.526315789473684
        },
        {
          "label": "Luminaires by the lumen method, before rounding up",
          "value": 30.303030303030297
        },
        {
          "label": "Rows along the length",
          "value": 8
        },
        {
          "label": "Luminaires in each row, across the width",
          "value": 4
        },
        {
          "label": "Luminaires in that grid",
          "value": 32
        },
        {
          "label": "Pitch along the length",
          "value": 1.5,
          "unit": "m"
        },
        {
          "label": "Pitch across the width",
          "value": 2,
          "unit": "m"
        },
        {
          "label": "Largest pitch the SHR allows",
          "value": 2.85,
          "unit": "m"
        },
        {
          "label": "Average illuminance the grid gives",
          "value": 528.0000000000001,
          "unit": "lx"
        }
      ],
      "basis": "cited",
      "sourceIndex": 0
    }
  ],
  "usedByAssemblies": [
    {
      "id": "recessed-lighting",
      "name": "Recessed lighting layout"
    }
  ]
}